Chapter 6 Description of Function Codes
- 77 -
It is used to set the limit of door open and close times in demonstration mode. When the
actual door open and close times in demonstration mode is equal to or greater than F7-03,
demonstration running ends automatically. When F7-03 is set to 0, this function is invalid, and
demonstration running does not end automatically.
Group F8: Auxiliary Parameters
Function Code
Parameter Name
Setting Range
Default
Min. Unit
F8-00
Software version
0.00–99.99
1.00
0.01
It is used to indicate the current software version of the controller.
Function Code
Parameter Name
Setting Range
Default
Min. Unit
F8-01
Module temperature
0–100°C
0°C
1°C
It is used to record the temperature of the bottom-level module in the controller.
Function Code
Parameter Name
Setting Range
Default
Min. Unit
F8-02
Fault auto reset times
0–100
0
1
The controller stops running after a fault occurs, and automatically resets and continues
running after an interval of 2s.
If this parameter is set to 0, the automatic reset function is disabled, and faults must be
reset manually. If no fault occurs or manual reset is performed within an hour, the controller
automatically clears the reset times.
Note
The controller does not automatically reset faults Er19 (Motor auto-tuning fault), Er26 (Prompt of
incorrect parameter setting), and Er27 (Door width auto-tuning fault).
Function Code
Parameter Name
Setting Range
Default
Min. Unit
F8-03
Brake use ratio
0–100%
100%
1%
It is valid for the controller with a built-in braking unit and used to adjust the braking effect of
the brake unit.
Function Code
Parameter Name
Setting Range
Default
Min. Unit
F8-04
Accumulative power-on time
0–9999 h
0
1
It is used to record the actual accumulative power-on operation time (hour) of the controller.
After the value exceeds the maximum value 9999 hours, the controller starts a new round of
counting.
Function Code
Parameter Name
Setting Range
Default
Min. Unit
F8-06
Accumulative running time
0–9999 h
0
1
It is used to record the accumulative running time (hour). After the value exceeds the maximum
Summary of Contents for NICE-D-A-S0P2
Page 6: ...1 Safety Information and Precautions...
Page 12: ...2 Product Information...
Page 16: ...3 Mechanical and Electrical Installation...
Page 23: ...Chapter 3 Mechanical and Electrical Installation 22...
Page 24: ...4 Operation and Trial Running...
Page 41: ...Chapter 4 Operation and Trial Running 40...
Page 42: ...5 Function Code Table...
Page 54: ...6 Description of Function Codes...
Page 89: ...Chapter 6 Description of Function Codes 88...