background image

MTIO-2824RND

Multi-functional Remote I/O Module 

User Guide

Suzhou Inovance Technology Co., Ltd.

Add.: No. 16 Youxiang Road, Yuexi Town, Wuzhong District, 

Suzhou 215104, P.R. China

Website: http://www.inovance.com

19011178A01

*19011178A01*

Summary of Contents for MTIO-2824RND

Page 1: ...D Multi functional Remote I O Module User Guide Suzhou Inovance Technology Co Ltd Add No 16 Youxiang Road Yuexi Town Wuzhong District Suzhou 215104 P R China Website http www inovance com 19011178A01...

Page 2: ...ww inovance com Intended Audience This user guide is intended for the users including electrical engineers software engineers and system engineers of computer numerical control CNC machine tools such...

Page 3: ...items in the user guide do not indicate all safety precautions that need to be followed instead they just supplement the safety precautions 4 Use this equipment according to the designated environment...

Page 4: ...n DANGER Equipment installation must be performed only by professional maintenance personnel who have been trained on necessary electrical knowledge The controller adopts the microcomputer design Keep...

Page 5: ...tion regulations A cable with a sufficient diameter must be used for reliable grounding For details see the wiring descriptions in the user guide Verify the connector type before you connect a cable C...

Page 6: ...ocket to avoid equipment damage caused by excessive voltage fluctuation Disposal WARNING The computer is configured with a real time clock circuit powered by batteries Improper installation of the bat...

Page 7: ...le describes the safety signs Safety Sign Description Read the user guide before installation and operation Failure to comply will result in an electric shock Do not remove the cover at power on or wi...

Page 8: ...4VDC 1A Ver 1 0 0 SERIAL NO 01840001xxxxxxxx Serial No Rated output OUTPUT 24VDC 0 4A MT IO 2824 RN D Code Module Type IO I O extension module Code Product Family MT Machine tool Code Output Type Rela...

Page 9: ...tion 10 No Terminal Name Function 1 Power terminal Mark Description Connected to PE case ground 0V 0 V power ground 24V 24 V power supply 2 Analog input output terminal The terminal is marked as AI AO...

Page 10: ...gn Output Spindle pulse output Sign 2 Sign Output Spindle pulse output Sign 3 Pulse Output Spindle pulse output Pulse 4 Pulse Output Spindle pulse output Pulse 5 GND Digital ground Digital signal grou...

Page 11: ...frequency 9 GND Signal input GND terminal 10 HSX Signal input Axis X selected 11 HSY Signal input Axis Y selected 12 HSZ Signal input Axis Z selected 13 HSU Signal input Axis U selected 14 HSV Signal...

Page 12: ...output channel Two 10 V to 10 V outputs or sampling channels with delay less than 1 ms Pulse output mode Three modes including direction pulse quadrature pulse and CW CCW pulse Maximum output frequen...

Page 13: ...Crimping wiring terminal Output type NPN type Output voltage range DC 15 29 V Maximum output impedance 1 Maximum load current of single channel 0 2 A Maximum leakage current at OFF 10 A Maximum outpu...

Page 14: ...perature 0 to 55 Full range 1 Output Channel type Analog voltage output Voltage output load 1 10 k Output voltage range 10 V to 10 V Output maintained When the system is stopped or abnormal the output...

Page 15: ...0 Front view Top view 32 0 115 0 8 5 4 5 4 8 195 105 0 35 4 Left view Installation The module can be installed on the guide rail The electrical connection between the module and guide rail can be real...

Page 16: ...d twisted pair Crystal head of a network port connector 8P8C 3 cross type Network cable with a shield layer General network cable Length requirement The FastEthernet technology proves that a cable con...

Page 17: ...input 6 DI16 Input Bit 16 of digital input 7 DI3 Input Bit 3 of digital input 8 DI17 Input Bit 17 of digital input 9 DI4 Input Bit 4 of digital input 10 DI18 Input Bit 18 of digital input 11 DI5 Inpu...

Page 18: ...gital output 19 24V 24 V power supply 20 0V COM terminal for digital output Definition of relay output RO terminals No Name Direction Function No Name Direction Function 16 ROUT0 Output Bit 0 of user...

Page 19: ...owing figure SS1 on the right is connected to 0 V It is source input and active at high level SS1 on the right can be connected to 24 V too In this case it is sink input and active at low level SS0 an...

Page 20: ...F will be produced between contacts and arc discharge is also caused when the inductive load stops This may result in contact failure or contact sag shortening the contact lifetime Therefore it is rec...

Page 21: ...ic shock protection when using inductive load Inductive load PCL output contct Surge absorber 2 Electric shock protection when using capacitive load When the capacitive load is applied the impulse cur...

Page 22: ...indicators PWR RUN and ERR and I O status indicators The number of I O status indicators is determined by the I O terminals used When an I O terminal is valid its corresponding indicator is on Indica...

Page 23: ...mmunication and AO Off EtherCAT communication state machine in the Normal state Blinking EtherCAT communication synchronization loss Single flash EtherCAT communication state machine Eeprom error Doub...