Chapter 4 Functional Parameters
-
33
-
Parameter
Name
Setting Range
Factory Setting Unit Operation
F0-08
Auxiliary function
selection
0–65535
0
-
★
The auxiliary functions of the system are described in the following table.
Table 4-2 Auxiliary functions indicated by bits of F0-08
Bit
Description
Bit0
0: Escalator running not available when the auxiliary brake is applied
1: Escalator running available only in the upward direction when the auxiliary brake is
applied
For some escalators, the auxiliary brake has the braking effect only in the downward
direction and can be released only after the escalator runs upward for a certain
distance. In this case, set Bit0 to 1. The running in the upward direction can last
only10s each time. If the running times out, the MCTC-PES-E1 disconnects outputs,
forces the escalator to stop running and reports fault Err10. After the fault is reset, the
escalator can run upward for 10s again.
Bit1
0: Auxiliary brake available
1: Auxiliary brake unavailable
Not all escalators must install the auxiliary brake. If Bit1 is set to 1, the MCTC-PES-E1
disconnects only Y3 and Y4 (the two relays stop the output).
Bit2
0: Step loss not detected during inspection
1: Step loss detected during inspection
Bit3
0: Handrail underspeed not detected during inspection
1: Handrail underspeed detected during inspection
Bit4
0: Brake not detected during inspection
1: Brake detected during inspection
Bit5
0: Detection of handrail speed pulse frequency too high enabled
1: Detection of handrail speed pulse frequency too high disabled
Bit6
Reserved
Bit7
0: Feedback signal detected after brake release
1: Feedback signal not detected after brake release
NOTE
◆
The signals input by X10 and X11 are not detected in the system inspection
state.