20
Chapter 5 Function Parameters
Note: the symbols in attribute column in the function parameters table are defined as follows:
“
○
” means that the parameter can be modified when the inverter is running or stops.
“×” means that the parameter cannot be modified when the inverter is running
“*” means that the parameter value is the actually measured value and cannot be modified.
“-” means that this parameter is default and can only be set by the manufacturer, whereas users’
operation is forbidden.
F0 Common Parameters
Func.
Code
Name
Setting Range
Min. unit
Default
Modified
Serial
No.
F0-00 Control mode
0: Sensorless vector control (SVC)
1: Reserved
2: V/F control
1
2
×
0
F0-01
Command source
selection
0: Operation panel (LED On)
1: Terminal (LED Off)
2: Communication control
1
0
○
1
F0-02
Frequency source
selection
0: Digital setting (not memorize)
1: Digital setting (memorize)
2: Pulse setting (Dl4 input is valid)
3: panel potentiometer setting
4: AI setting
5: Multi-speed
6: Communication reference
1
3
×
2
F0-03
Auxiliary frequency
source selection
0: Invalid
1: Valid, related to main reference
2: Valid, related to maximum frequency
(the auxiliary frequency source is AI and
valid only when F0-02 is selected by 0, 1, 2
or 3)
1
0
×
3
F0-04
Digital preset
frequency
0.0Hz ~ Maximum frequency
(valid if the frequency source selection
mode is digital setup)
0. 1Hz
50.0Hz
○
4
F0-05 Acceleration time
0.1s~3000.0s
0.0
20.0s
○
5
F0-06 Deceleration time
0.1s~3000.0s
0.0
20.0s
○
6