5 Parameter Table
- 23 -
5� Parameter List
5�1 Introduction
Groups F and A include basic and hydraulic function parameters� Group U includes the monitoring function parameters and
extension card communication parameters�
The parameter description tables in this chapter use the following symbols� The symbols in the parameter table are described as follows:
Symbol
Meaning
☆
It is possible to modify the parameter with the drive in the stop or in the run status�
★
It is not possible to modify the parameter with the drive in the run status�
●
The parameter is the actual measured value and cannot be modified.
*
The parameter is a factory parameter and can be set only by the manufacturer�
5�2 Hydraulic Control and Basic Control Parameter List
Para� No� Para� Name
Setting Range
Unit
Default
Property
Group A0: Flux Weakening Control
A0-00
Flux weakening method selection
0: by calculation
1: auto adjusted
1
1
★
A0-01
Flux weakening current factor
0 to 500
1
5
☆
A0-02
Pm motor flux weakening depth
0 to 50
%
5
☆
A0-03
Factor of pm motor max� output
torque
20 to 300
%
100
☆
A0-04
Factor of pm motor field current
40 to 200
%
100
☆
Group A1: PG Card
A1-00
PG card type selection
0: resolver
1: reserved
2: ABZ encoder
1
0
★
A1-02
Encoder installation angle
0�0 to 359�9
°
0
☆
A1-03
Speed feedback direction
0: same
1: reverse
1
-
★
A1-04
Number of resolver pole-pairs
1 to 50
1
Model
dependent
★
A1-05
Resolver fault detection time
0�000 to 60�000
Sec
2�000
☆
A1-06
Encoder resolution
0 to 65535
1
1024
★
A1-08
Speed sensor interference counts
0 to 60000
1
0
☆
Group A2: CAN Communication
A2-00
Baud rate
0: 20
1: 50
2: 125
3: 250
4: 500
5: 1024
kHz
4
☆
A2-01
CANLink address
1 to 64
1
1
☆
A2-02
CANLink continuous communication
time
0�1 to 600�0
sec
0�3
☆
A2-03
CANLink multi-pump mode selection 0: broadcast
1: multi masters
1
0
☆
A2-04
CANLink slave address 1
0 to 65535
1
0
☆