Test the handle: Test the valve,
water temperature will decrease
when you clockwise rotate, and
water temperature will increase
when you anti clockwise rotate.
Caution!
If you need to adjust
temperature more than 100°F, then
you need to press the overrides.
Button and make a anti-clockwise
rotate. It should not be possible to
turn the stem further
counter-clockwise.
9-
Using the spanner to anti
clockwise stops (1).
Take out filter (2) and check Valve
(3).
Using clear water to rinse filter (2).
Slide filter (2) to check Valve (3).
then thread it to the valve body.
Using the spanner to connect
stops (1 )to the valve.
Clean the stops filters:
1-
2-
3-
4-
5-
100°
1
2
3
1
2
3
For warranty issues call us at 1-855 472 4304 or send us an e-mail at [email protected]