background image

The Innovative Marine HELIO Universal Controller provides aquarium 

hobbyists the industry’s premium cutting edge heating temperature 

control technology with multi-phase redundant safety. Complimented 

with a titanium sensor to better regulate and assure overheating does 

not occur while staying within consistent preset temperature 

parameters.

Say hello to the HELIO Universal Controller. 

The HELIO Controller houses a circuit board processor which is the 

heart and mastermind of the controller. By continuously constructing a 

bevy of temperature readings from the controller and titanium sensor, 

there is constant communication verifying and ensuring temperature 

accuracy. The result is when a temperature difference is detected, there 

is an immediate cease of power to the jacks, plus an audible notification 

that your aquarium ecosystem is not at a consistent optimal operating 

temperature.

Table of Contents

Introduction

Introduction.......................................................................................................... 3-4

Read Me.................................................................................................................. 5-6

Warnings..................................................................................................................... 7

Parts List...................................................................................................................... 8

Controller Specifications........................................................................................9

Set Up

 

Set Up & Installation.........................................................................10-11

 

Remote Sensor Placement.............................................................12-13

Key Operation

 

How to Set Temperature...................................................................... 14

 

How to Calibrate Temperature........................................................... 15

 

How to Set High Alarm......................................................................... 16

 

How to Set Low Alarm.......................................................................... 17

Error Codes....................................................................................................... 18-19

Maintenance.......................................................................................................... 20

2

3

Summary of Contents for HELIO Universal Controller

Page 1: ...Universal Controller H E L I O TM Read this guide for operation and safety precautions prior to usage Follow this guide on how to use the controller correctly www innovative marine com...

Page 2: ...onstructing a bevy of temperature readings from the controller and titanium sensor there is constant communication verifying and ensuring temperature accuracy The result is when a temperature differen...

Page 3: ...the following situations do not attempt to repair yourself Return the appliance to Innovative Marine for service or discard the appliance If the controller falls into water DO NOT reach for it First u...

Page 4: ...he plug and pull to disconnect Do not use an appliance for other than intended use The use of attachments not recommended or sold by the appliance manufacturer may cause an unsafe condition Do not ins...

Page 5: ...ble Alarm Off Power Indicator Element Indicator Line One Element Indicator Line Two Mode Button Increase Temperature Decrease Temperature Audible Alarm Toggle Switch On Off Factory Preset Temperature...

Page 6: ...ug Connect the heating element to this plug Attach sensor to the magnetic holder Attach the magnetic backing to secure the sensor in your aquarium Magnetic holder strength up to 1 2 thick Connect remo...

Page 7: ...or Placement AIO Placement Sump Placement 12 13 water line Rear view of an AIO Follow Manufacturer guidelines for heating element placement Interior view of a sump water line Follow Manufacturer guide...

Page 8: ...ou can increase or decrease your desired calibration by 0 1 F increments Temp Set Range 9 F Wait 3 seconds then your calibrated temperature will be automatically saved M Mode Button Increase Temperatu...

Page 9: ...crease your desired temperature by 1 0 F Low alarm general range 57 93 F Low alarm minimum range 2 F from set temp Wait 3 seconds then your set temperature will be automatically saved How to Set High...

Page 10: ...point E4 Low Temperature Alarm The aquarium s water temperature has subceeded the low temperature set point E7 Remote Sensor Error Remote sensor has been detected to be out of water or a sudden tempe...

Page 11: ...O Universal Controller for at least 1 hour before cleaning Soak the and sensor in a solution of 1 part vinegar to 1 part water for an hour or as needed DO NOT soak the connectors in the cleaning solut...

Page 12: ...www innovative marine com warranty innovative marine com 866 368 7941...