background image

Stop

On

Set

10 hours later

(Auto-off Operation)

The TIMER OFF feature is useful when you want the
unit to turn off automatically after you go to bed. The
air conditioner will stop automatically at the set time.

To stop the air conditioner in 10 hours.
1. Press the TIMER OFF button, the last setting of

stopping operation time and the signal "H" will
show on the display area.

2. Press the TIMER OFF button to display "10H " on

the TIMER OFF display of the remote controller.

3. Wait for 3 seconds and the digital display area

will show the temperature again. The "TIMER
OFF" indicator remains on and this function is
activated.

TIMER OFF

Example:

On

Stop

2 hours later
after setting

Set

To stop the air conditioner 2 hours after setting and
start it again 10 hours after setting.
1. Press the TIMER OFF button.
2. Press the TIMER OFF button again to display

2.0H on the TIMER OFF display.

3.
4. Press the TIMER ON button again to display 10H

on the TIMER ON display .

5.

Press the TIMER ON button.

Wait for 3 seconds and the digital display area

will show the temperature again. The "TIMER
ON OFF" indicator remains on and this function is
activated.

TIMER OFF

TIMER ON

(On

Stop

Start operation)

This feature is useful when you want to stop the air
conditioner after you go to bed, and start it again in
the morning when you wake up or when you return
home.

Example:

COMBINED TIMER

(S

both ON and OFF

)

etting

timers simultaneously

Start

10 hours later
after setting

Example:

TIMER ON

TIMER OFF

(Off

Start

Stop operation)

This feature is useful when you want to start
the air conditioner before you wake up and
stop it after you leave the house.

To start the air conditioner 2 hours after setting,
and stop it 5 hours after setting.
1. Press the TIMER ON button.
2. Press the TIMER ON button again to display

2.0H on the TIMER ON display.

3. Press the TIMER OFF button.
4. Press the TIMER OFF button again to display

5.0H on the TIMER OFF display .

5. Wait for 3 seconds and the digital display area

will show the temperature again. The "TIMER
ON & TIMER OFF" indicator remains on and
this function is activated.

Off

Stop

Start

2 hours later
after setting

5 hours later
after setting

Set

8m

Use the remote controller within a distance of 8
meters from the appliance, pointing it towards the
receiver. Reception is confirmed by a beep.

Location of the remote controller.

CAUTIONS

The air conditioner will not operate if curtains,
doors or other materials block the signals from
the remote controller to the indoor unit.
Prevent any liquid from falling into the remote
controller. Do not expose the remote controller
to direct sunlight or heat.
If the infrared signal receiver on the indoor unit
is exposed to direct sunlight, the air conditioner
may not function properly. Use curtains to
prevent the sunlight from falling on the receiver.
If other electrical appliances react to the remote
controller, either move these appliances or
consult your local dealer.
Do not drop the remote controller. Handle with
care.
Do not place heavy objects on the remote
controller, or step on it.

Handling the remote controller

Summary of Contents for RCTL-OASISP

Page 1: ...rol User Manual Mini Split System In order to get the highest performance from your system please read this instruction manual carefully before you start using it and save it for future reference www innovair com ...

Page 2: ...ration Cooling Heating Fan operation Dehumidifying operation Timer operation 23 F 140 F O O NOTE Buttons design is based on typical model and might be slightly different from the actual one you purchased the actual shape shall prevail All the functions described are accomplished by the unit If the unit has no this feature there is no corresponding operation happened when press the relative button ...

Page 3: ...ep feature if activated If pushing more than 2 seconds the system will automatically restore the current operation settings including operating mode setting temperature fan speed level and sleep feature if activated O UP Button Push this button to decrease the indoor temperature setting in 1 F increments to 62 F o o DOWN Button 8 7 Press this button to initiate the auto on time sequence Each press...

Page 4: ...yed when TIMER ON time is set Displayed in Sleep Mode operation Not available for this unit Not available for this unit Displayed when TIMER OFF time is set Show set temperature or room temperature or time under TIMER setting AUTO HEAT FAN COOL DRY SWING Button DIRECT Button Used to change the louver movement and set the desired up down air flow direction The louver changes 6 in angle for each pre...

Page 5: ...the air conditioner O O O 1 In the Auto mode the air conditioner can logically choose the mode of Cooling Fan and Heating by sensing the difference between the actual ambient room temperature and the setting temperature on the remote controller 2 In the Auto mode you can not switch the fan speed It has already been automatically controlled 3 If the Auto mode is not comfortable for you the desired ...

Page 6: ...ng the TIMER OFF there will be a one second delay before the remote controller transmits the signal to the air conditioner Then after approximately another 2 seconds the signal H will disappear and the set temperature will re appear on the LCD display window MODE FAN TEMP ON OFF SHORT CUT TIMER ON TIMER OFF When you select the timer operation the remote controller automatically transmits the timer...

Page 7: ...r setting Example TIMER ON TIMER OFF Off Start Stop operation This feature is useful when you want to start the air conditioner before you wake up and stop it after you leave the house To start the air conditioner 2 hours after setting and stop it 5 hours after setting 1 Press the TIMER ON button 2 Press the TIMER ON button again to display 2 0H on the TIMER ON display 3 Press the TIMER OFF button...

Page 8: ...omply with the local national regulations In Canada it should comply with CAN ICES 3 B NMB 3 B In USA this device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This equipment has been tested ...

Reviews: