background image

How to use the buttons

Cooling /Heating/Fan operation

MODE

UP/DOWN

FAN

ON/OFF

Ensure the unit is plugged in and power is
available.
1. Press the

button to select COOL,

HEAT(cooling & heating models only) or
FAN mode.

2. Press the

buttons to set the

desired temperature.

3. Press the

button to select the fan speed

in four steps- Auto, Low, Med,or High.

4. Press the

button to start the air

conditioner.

The temperature can

be set within a range of 62 F~ 86 F in 1 F
increments.

O

O

O

In the FAN mode, the setting temperature is not
displayed in the remote controller and you are not
able to control the room temperature either. In this
case, only step 1, 3 and 4 may be performed.

NOTE

Auto operation

MODE

UP/DOWN

ON/OFF

Ensure the unit is plugged in and power is
available. The OPERATION indicator on the
display panel of the indoor unit starts flashing.
1. Press the

button to select Auto.

2. Press the

button to set the

desired temperature. The temperature can
be set within a range of 62 F~ 86 F in 1 F
increments.

3. Press the

button to start the air

conditioner.

O

O

O

1. In the Auto mode, the air conditioner can logically

choose the mode of Cooling, Fan, and Heating
by sensing the difference between the actual
ambient room temperature and the setting
temperature on the remote controller.

2. In the Auto mode, you can not switch the fan speed.

It has already been automatically controlled.

3. If the Auto mode is not comfortable for you , the

desired mode can be selected manually.

NOTE

MODE

FAN

TEMP

ON/OFF

SHORT

CUT

TIMER

ON

TIMER

OFF

4

1

3

2

MODE

FAN

TEMP

ON/OFF

SHORT

CUT

TIMER

ON

TIMER

OFF

3

1

2

Dehumidifying operation

MODE
UP/DOWN

ON/OFF

Ensure the unit is plugged in and power is
available. The OPERATION indicator on the
display panel of the indoor unit starts flashing.
1. Press the

button to select DRY mode.

2. Press the

buttons to set the

desired temperature.

3. Press the

button to start the air

conditioner.

The temperature

can be set within a range of 62 F~ 86 F in
1 F increments.

O

O

O

In the Dehumidifying mode, you can not switch the

fan speed. It has already been automatically controlled.

NOTE

MODE

FAN

TEMP

ON/OFF

SHORT

CUT

TIMER

ON

TIMER

OFF

3

1

2

How to use the buttons

SLEEP

SLEEP

SLEEP

TURBO

TURBO

TURBO

SWING DIRECT

SWING DIRECT

SWING DIRECT

LED

LED

LED

Summary of Contents for RCTL-OASISP

Page 1: ...rol User Manual Mini Split System In order to get the highest performance from your system please read this instruction manual carefully before you start using it and save it for future reference www innovair com ...

Page 2: ...ration Cooling Heating Fan operation Dehumidifying operation Timer operation 23 F 140 F O O NOTE Buttons design is based on typical model and might be slightly different from the actual one you purchased the actual shape shall prevail All the functions described are accomplished by the unit If the unit has no this feature there is no corresponding operation happened when press the relative button ...

Page 3: ...ep feature if activated If pushing more than 2 seconds the system will automatically restore the current operation settings including operating mode setting temperature fan speed level and sleep feature if activated O UP Button Push this button to decrease the indoor temperature setting in 1 F increments to 62 F o o DOWN Button 8 7 Press this button to initiate the auto on time sequence Each press...

Page 4: ...yed when TIMER ON time is set Displayed in Sleep Mode operation Not available for this unit Not available for this unit Displayed when TIMER OFF time is set Show set temperature or room temperature or time under TIMER setting AUTO HEAT FAN COOL DRY SWING Button DIRECT Button Used to change the louver movement and set the desired up down air flow direction The louver changes 6 in angle for each pre...

Page 5: ...the air conditioner O O O 1 In the Auto mode the air conditioner can logically choose the mode of Cooling Fan and Heating by sensing the difference between the actual ambient room temperature and the setting temperature on the remote controller 2 In the Auto mode you can not switch the fan speed It has already been automatically controlled 3 If the Auto mode is not comfortable for you the desired ...

Page 6: ...ng the TIMER OFF there will be a one second delay before the remote controller transmits the signal to the air conditioner Then after approximately another 2 seconds the signal H will disappear and the set temperature will re appear on the LCD display window MODE FAN TEMP ON OFF SHORT CUT TIMER ON TIMER OFF When you select the timer operation the remote controller automatically transmits the timer...

Page 7: ...r setting Example TIMER ON TIMER OFF Off Start Stop operation This feature is useful when you want to start the air conditioner before you wake up and stop it after you leave the house To start the air conditioner 2 hours after setting and stop it 5 hours after setting 1 Press the TIMER ON button 2 Press the TIMER ON button again to display 2 0H on the TIMER ON display 3 Press the TIMER OFF button...

Page 8: ...omply with the local national regulations In Canada it should comply with CAN ICES 3 B NMB 3 B In USA this device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This equipment has been tested ...

Reviews: