Innova Integralift FC-230 Service Manual Download Page 5

 

 

 

 

 
 

 

 
1.  Vertical structure 
2. 

Brackets

 forstructure 

3.  Backjib 
4.  Shaft for back jib 
5.  Frontjib with engine 
6. 

Bracket

forfrontjib 

7.  Shaft for front jib 

8.  Top Cabinet 
9.  Handle 

10. Rear cover 

11. Charger 
12. Vertical cabinet 
13. Cabinet base 
14. Cabinet front doors 

15. Lifting tape 
16. Spreader bar 
17. Remote control 
18. Emergency stop 
19. Sling 

 

 

 

12 

14 

10 

11 

13 

15 

16 

17 

18 

19 

Summary of Contents for Integralift FC-230

Page 1: ...Yesterday s challenge Today s solution innova uk com Service Manual ...

Page 2: ... 2 3 3 4 5 6 6 7 8 9 10 11 12 14 Explanation of symbols CE Warning Read User Manual Product for indoor use ...

Page 3: ...pted to both User and spreader bar The sling is mounted correctly around the User The sling is fastened correctly to the spreader bar both before the lifting tape is tensioned and before the User is lifted from the bed Max user weight Max user weight for Integralift 230 is 230 kg Integralift consists of a vertical cabinet and a top cabinet The lift is integrated in the top cabinet and consists of ...

Page 4: ...Can be installed in almost every home or institution with the versatile Integralift structure system This means easier projects for architects and builders Warranty 2 years Lifecycle 10 years with service agreement 10 000 lifting cycles Maximum load 230 kg Battery 24 V DC 4 5 Ah sealed lead battery 40 lifting cycles Battery charger 100 240 V AC 40 60 Hz max 1 300 mA Lifting speed 50 70 mm sec Lift...

Page 5: ...with engine 6 Bracketforfrontjib 7 Shaft for front jib 8 Top Cabinet 9 Handle 10 Rear cover 11 Charger 12 Vertical cabinet 13 Cabinet base 14 Cabinet front doors 15 Lifting tape 16 Spreader bar 17 Remote control 18 Emergency stop 19 Sling 12 8 1 3 5 9 4 2 2 6 7 14 10 11 13 15 16 17 18 19 ...

Page 6: ...940 24V max 1300mA Power Cord Connector cable 20 Drum house Motor module Control board Interface card Battery set 2x12V 5 4Ah Model Capacity A B C D E F WM 230 230 kg 220 225 130 95 35 31 FC 230 230 kg 230 330 130 95 35 31 IW 230 230 kg 230 500 130 95 35 31 All measurements A F in centimeters ...

Page 7: ...prying it through the M shape a The lifting tape must be inserted fully in the track b Roll lifting tape clockwise seen from the end of the front jib c The double stretch of the lifting tape registers end stop must face towards drum 5 Pull lifting tape through the two drum openings and pull lifting tape through the rollers Pict 7 the M shaped opening 6 Attach the lift tape to the spreader bar see ...

Page 8: ...crew the screw and place the new spreader bar in the lifting tape 3 The spreader bar screw is to be tightened thoroughly with a screwdriver 15 nm moment minimum 4 Employ a shrink tube or a thick tape to secure the screw 5 Register the change of spreader bar or lifting tape in the log 1 2 ...

Page 9: ...tery and motor b The control board should beep 3 times and the green light blink when power is supplied or battery is connected 5 Attach the control board with the same four screws 6 Inspect that motor switch under the control board is activated green side visible 7 Test Integralift functionality and close rear cover 8 Register the change of control board in the log 2 3 6 Connector cable Motor Bre...

Page 10: ...ctor cable from the connector card 3 Unscrew the four holding screws locknuts pictured in top picture left 4 Gently pull the drum and drum house from the motor shaft 5 Attach the new drum house attach the connector cable 6 Re position top cabinet and rear cover 7 Test Integralift functionality 8 Register the change of drum house in the log 2 3 5 ...

Page 11: ...ws with nuts on top 4 Gently pull the motor house backwards and off the drum 5 Insert the new motor module and re attach the removed cables NB Make sure no wires get trapped 6 Re position rear cover and top cabinet 7 Test Integralift functionality 8 Register the change of motor module in the log NB If the motor controller card or batteries have errors these parts are to be sent to Innova for inspe...

Page 12: ...r switch activated 3 Connector cable connected with interface card 4 All cables connected with controller card ii Test with new connector cable iii If Control board does not blink green 1 Control board 10 A blue fuse broken Replace the fuse This will be an effect of overload or control board error 2 Control board 5 A blue fuse broken Replace the fuse Incorrect polarization on charger or control bo...

Page 13: ...room features is done correctly and all screws sufficiently tightened b Check that noise disappears during usage if not contact Innova or your local retailer 2 Is the noise coming from bearings between the jibs and or structure a Identify the source of the noise and add a small amount of teflon lubricant between steel bracket and the bolt not at plastics b Check that noise disappears during usage ...

Page 14: ...tening wall ceiling Screws used Structure Vertical structure Jibs Bracketts Driving unit and lifter Motor Band Sling bar Remote control Electronics Cables and connectors Battery and charger Circuit card Emergency stop Emergency lowering Documentation Product branding with SWL Usermanual Status X OK 1 Observation needed 2 Immediate repairs needed 3 Withdraw from usage Weight Tested with safe workin...

Page 15: ...4 1451 e enquiries innova uk com www innova uk com Yesterday s challenge Today s solution Innova is a trading name of CoreCare Global Ltd a company registered in England Wales at Linkside House Forest Lane Head Harrogate HG2 7TE Registered Company Number 08931470 Dealer ...

Reviews: