Live Data Mode
RECORDING (CAPTURING) LIVE DATA
OBD2 67
1.
While linked to the vehicle, start the
engine, then press and release the
button.
The “Mode Selection Menu” displays.
2.
Use the
UP
and
DOWN
buttons, as necessary, to highlight
Live
Data
, then press the
ENTER
button.
The “Live Data” menu displays.
3.
Use the
UP
and
DOWN
buttons, as necessary, to highlight
“Record Live Data”, then press the
ENTER
button.
The "Record Live Data Menu" dis-
plays.
4.
Use the
UP
and
DOWN
buttons, as necessary, to highlight
“Record by manual trigger”, then press
the
ENTER
button.
5.
When the "Record by Manual Trigger" screen displays, select the
desired trigger point as follows:
The Scan Tool is capable of recording approximately 100
frames of Live Data. Record by DTC trigger lets you select the
point in time at which you wish the Scan Tool to begin
recording Live Data. You can set the trigger point to record the
100 frames of data before an event (when the DTC was set),
after the event, or in the middle (50 frames before and 50
frames after the event.
Beginning
- records approximately
100 frames of Live Data after the
ENTER
button was pressed.
Middle
- records approximately 50
frames of Live Data before and 50
frames after the
ENTER
button
was pressed.
End
- records approximately 100 frames of Live Data before the
ENTER
button was pressed.
6.
Use the
UP
and
DOWN
buttons, as necessary, to select the
desired trigger point, then press the
ENTER
button.
A "One moment please. . ." message
shows on the display. When the
Scan Tool is ready to record Live
Data, the "Record Live Data" screen displays.