Page 6 of 10
Version 26/07/2016
INNOTECH
POINT-11
INNO
TECH
POINT-11
INSTALLING THE EYE BOLT (ATTACHMENT POINT)
Seal in the POINT.
Use M12 lock nut to fasten the eye bolt
(attachment point).
ATTENTION:
When fastening use a 19 mm fork
wrench to ensure that the POINT
does not turn.
After fastening loosen the lock nut a
¼ (quarter) turn; the attachment point
will now rotate 360° around its own axis.
Check: The lock nut should free
min. 2 thread turns of the
stud bolt. (See detail)
Attention: The single anchorage point can be plastically deformed!