background image

Page 6 of 10 

Version 26/07/2016 

INNOTECH  

POINT-11

 

INNO

TECH

   

POINT-11

 

 
 

INSTALLING THE EYE BOLT (ATTACHMENT POINT) 
 
 

 

 

Seal in the POINT. 
 

 
 

 

Use M12 lock nut to fasten the eye bolt  
(attachment point). 
 

ATTENTION:

 

When fastening use a 19 mm fork  

wrench to ensure that the POINT  
does not turn. 

 
 

 
 

 

After fastening loosen the lock nut a  

¼ (quarter) turn; the attachment point  
will now rotate 360° around its own axis. 

 

Check: The lock nut should free  
min. 2 thread turns of the  

stud bolt. (See detail)

 

 

 

 
 
 

 
 

Attention: The single anchorage point can be plastically deformed!

Summary of Contents for POINT-11

Page 1: ...de veiligheidsinrichting is pas toegestaan nadat de monteur en de gebruiker de originele montage en gebruikershandleiding in de desbetreffende taal gelezen hebben Figyelem MAGYAR A biztons gi berendez...

Page 2: ...doubt consult a structural engineer The anchorage device on the roof is designed for stress in all directions parallel to the installation surface or at right angles to the anchor If uncertainties ari...

Page 3: ...ete safety device The inspection by the expert must be documented on the provided control card After a fall and the resulting strain you must stop using the restraint system and have it checked by an...

Page 4: ...he following information Type designation INNOTECH POINT 11 Number s of the applicable standard s EN 795 2012 TYP A CEN TS 16415 2013 Name or logo of the manufacturer reseller INNOTECH Manufacturer s...

Page 5: ...overhead FASTENING IN WOOD The basic prerequisite is a static bearing subconstruction and compliance with the installation instructions If in doubt consult a structural engineer Timber rafter dimensio...

Page 6: ...olt attachment point ATTENTION When fastening use a 19 mm fork wrench to ensure that the POINT does not turn After fastening loosen the lock nut a quarter turn the attachment point will now rotate 360...

Page 7: ...f the substrate etc OPTIONAL when setting up a horizontal lifeline system in accordance with EN 795 2012 TYP C INSTALLATION HORIZONTAL LIFELINE SYSTEM Specialist H Company address DESIGNATION HORIZONT...

Page 8: ...iew diagram showing the position of the anchorage devices Draw in the areas where there is a break through hazard e g light domes or and roof lights The maximum limit values of the anchorage devices a...

Page 9: ...ecifications Expiration date Annual inspection performed Not checked no authorisation ROOF SEALING No damage No corrosion VISIBLE PARTS OF THE ANCHORAGE DEVICE No deformation The attachment eye can ro...

Page 10: ...INNOTECH POINT 11 SALES AND DEVELOPMENT INNOTECH Arbeitsschutz GmbH A 4656 Kirchham Laizing 10 w w w i n n o t e c h a t...

Reviews: