INSTALLATION AND  

OPERATING MANUAL 

 

 

SAFETY INSTRUCTIONS 
 

 

INNOTECH-POINT may only be installed by competent experts familiar with the roof safety 
system. 

 

You must be familiar with these instructions, as well as with the local safety regulations as 
a prerequisite for installing and using the system. You must also be physically and 
mentally fit and trained in the use of PSE

 

(Personal Safety Equipment). 

 

Medical conditions (cardiovascular problems, intake of medicines, alcohol) can affect the 
safety of the user when working in high places. 

 

Adhere to the respective accident prevention regulations (e.g. working on roofs) when 
installing/using the INNOTECH POINT attachment device.  

 

A plan must be available that specifies rescue procedures for all possible emergencies. 

 

Before starting work, ensure that no objects can fall to the ground from the work site. The 

area below the work site (sidewalk, etc.) must be kept clear. 

 

The fitters must ensure that the substrate is suitable for fastening the anchorage device. 
If in doubt consult a structural engineer. 

 

The anchorage device on the roof is designed for stress in all directions parallel to the 
installation surface or at right angles to the anchor. 

 

If uncertainties arise during installation, it is imperative that you contact the 
manufacturer. 

 

The roof covering must be properly sealed in accordance with applicable guidelines. 

 

Document the professional fastening of the fall arrest system to the building with photos 

of each fitting situation. 

 

Ensure that stainless steel does not come into any contact with swarf or steel tools, as this 
may lead to corrosion. 

 

All stainless steel bolts must be greased with a suitable lubricant before installation. 

 

Plan, install, and use the anchorage point in such a manner that no one can fall over the 

edge if the personal safety equipment is used properly (see planning documents at 
www.innotech.at). 

 

At the access to the roof safety system you must document the positions of the anchorage 
devices by means of diagrams (e.g. view of the roof from above). 

 

The minimum free space required between the roof edge and the ground is calculated as 
follows: 

 

Manufacturer's specification of the personal safety equipment used + sag of the cable 

according to table + deflection of the cable + body 1 m safety margin. 

Summary of Contents for POINT-11

Page 1: ...de veiligheidsinrichting is pas toegestaan nadat de monteur en de gebruiker de originele montage en gebruikershandleiding in de desbetreffende taal gelezen hebben Figyelem MAGYAR A biztons gi berendez...

Page 2: ...doubt consult a structural engineer The anchorage device on the roof is designed for stress in all directions parallel to the installation surface or at right angles to the anchor If uncertainties ari...

Page 3: ...ete safety device The inspection by the expert must be documented on the provided control card After a fall and the resulting strain you must stop using the restraint system and have it checked by an...

Page 4: ...he following information Type designation INNOTECH POINT 11 Number s of the applicable standard s EN 795 2012 TYP A CEN TS 16415 2013 Name or logo of the manufacturer reseller INNOTECH Manufacturer s...

Page 5: ...overhead FASTENING IN WOOD The basic prerequisite is a static bearing subconstruction and compliance with the installation instructions If in doubt consult a structural engineer Timber rafter dimensio...

Page 6: ...olt attachment point ATTENTION When fastening use a 19 mm fork wrench to ensure that the POINT does not turn After fastening loosen the lock nut a quarter turn the attachment point will now rotate 360...

Page 7: ...f the substrate etc OPTIONAL when setting up a horizontal lifeline system in accordance with EN 795 2012 TYP C INSTALLATION HORIZONTAL LIFELINE SYSTEM Specialist H Company address DESIGNATION HORIZONT...

Page 8: ...iew diagram showing the position of the anchorage devices Draw in the areas where there is a break through hazard e g light domes or and roof lights The maximum limit values of the anchorage devices a...

Page 9: ...ecifications Expiration date Annual inspection performed Not checked no authorisation ROOF SEALING No damage No corrosion VISIBLE PARTS OF THE ANCHORAGE DEVICE No deformation The attachment eye can ro...

Page 10: ...INNOTECH POINT 11 SALES AND DEVELOPMENT INNOTECH Arbeitsschutz GmbH A 4656 Kirchham Laizing 10 w w w i n n o t e c h a t...

Reviews: