Functional earth ground
The functional earth ground can be used by the operator. This connection is electrically con-
nected to the back of the mGuard
industrial
rs.
The
mGuard
industrial
rs
is
grounded
when
it is mounted on a DIN rail with the metal clamp, which connects the back of the device to
the DIN rail. The DIN rail must be grounded.
Signal contact
The signal contact monitors the mGuard
industrial
rs
and
thus
enables
remote
diagnostics.
Interruption of the contact via the floating signal contact (relay contact, closed current cir-
cuit) indicates the following:
–
Failure of at least one of the two supply voltages.
–
Power supply of the mGuard
industrial
rs below the specified limit value (supply voltage
1 and/or 2 is less than 9 V).
–
The faulty link status of at least one port. The link status message for each port can be
masked on the mGuard
industrial
rs via the management software.
By default upon delivery, there is no connection monitoring.
–
Error during selftest.
During a restart, the signal contact is interrupted until the mGuard has started up complete-
ly. This also applies when the signal contact is manually set to “Closed” in the software con-
figuration.
Service contacts
A
push button
or an
on/off switch
(e.g., key switch) can be connected between
service
contacts CMD and _|_.
A standard
LED
(up to 3.5 V) or a corresponding optocoupler can be connected between
contacts ACK (+) and _|_ (-)
. The contact is short-circuit-proof and supplies 20 mA, max-
imum. The LED or optocoupler must be connected without preresistor (for wiring, see
Figure
12-6
to
Figure
12-8).
The
button
or
on/off switch
is used to establish and release a predefined VPN connection.
The LED indicates the status of the VPN connection (in the web interface under “IPsec VPN
>> Global >> Options”).
Operating a connected
button
•
To establish the VPN connection, hold down the button for a few seconds until the sig-
nal LED flashes. Only then release the button.
Flashing indicates that the mGuard has received the command to establish the VPN
connection and is establishing the VPN connection. As soon as the VPN connection is
established, the signal LED remains lit continuously.
•
To release the VPN connection, hold down the button for a few seconds until the signal
LED flashes or goes out. Only then release the button.
As soon as the signal LED goes out, the VPN connection is released.
Operating a connected
on/off switch
•
To establish the VPN connection, set the switch to the ON position.
•
To release the VPN connection, set the switch to the OFF position.
WARNING:
Only SELV circuits with voltage limitations according to EN 60950-1 may be
connected to the signal contact.
WARNING:
The service contacts (_|_, CMD, ACK) must not be connected to an external
voltage source; they should always be connected as described here.
Summary of Contents for mGuard
Page 6: ...Innominate Security Technologies...
Page 32: ...mGuard rs4000 rs2000 32 Innominate Security Technologies I15007_en_02...
Page 74: ...mGuard rs4000 rs2000 3G 74 Innominate Security Technologies I15007_en_02...
Page 108: ...mGuard pci SD 108 Innominate Security Technologies I15007_en_02...
Page 142: ...mGuard centerport 142 Innominate Security Technologies I15007_en_02...
Page 156: ...mGuard delta 156 Innominate Security Technologies I15007_en_02...
Page 180: ...mGuard pci 180 Innominate Security Technologies I15007_en_02...
Page 196: ...mGuard blade 196 Innominate Security Technologies I15007_en_02...
Page 236: ...mGuard industrial rs 236 Innominate Security Technologies I15007_en_02...
Page 254: ...EAGLE mGuard 254 Innominate Security Technologies I15007_en_02...