mGuard
industrial
rs
I15007_en_02
Innominate Security Technologies
219
•
To remove the mGuard
industrial
rs from the DIN rail, insert a screwdriver horizontally
in the locking slide under the housing, pull it down – without tilting the screwdriver – and
then pull up the mGuard
industrial
rs.
12.3.2
Connecting the supply voltage
The supply voltage is connected via a terminal block with screw locking, which is located on
the top of the device.
Figure
12-4
Supply
voltage
Supply voltage
–
NEC Class 2 power source 12
V
DC or 24
V
DC
–
-25% ... +33% Safety Extra Low Voltage (SELV/PELV, redundant inputs isolated)
–
5
A,
maximum
–
Buffer time 10
ms, minimum at 24
V
DC
Redundant power supply
A redundant supply voltage can be connected. Both inputs are isolated. The load is not dis-
tributed. With a redundant supply, the power supply unit with the higher output voltage sup-
plies the mGuard
industrial
rs alone. The supply voltage is electrically isolated from the
housing.
If the supply voltage is not redundant, the mGuard
industrial
rs indicates the failure of the
supply voltage via the signal contact. This message can be prevented by feeding the supply
voltage via both inputs.
12.3.3
Connecting to the network
LAN port
•
Connect the local computer or the local network to the LAN port of the mGuard using a
UTP Ethernet cable (CAT5).
WARNING:
The mGuard
industrial
rs is designed for operation with a DC voltage of
9
V
DC
...
36
V
DC/SELV,
0.5
A,
maximum.
Therefore, only SELV circuits with voltage limitations according to EN 60950-1 may be
connected to the supply connections and the signal contact.
WARNING:
Only connect the mGuard network ports to LAN installations.
When connecting to the network, use cables with bend protection on the plugs.
Cover unused sockets with the dust protection caps provided.
Some telecommunications connections also use RJ45 sockets; these must not be con-
nected to the RJ45 sockets of the mGuard.
Supply voltage
+24 V +0 V
+24 V -0 V
P1
P2
Summary of Contents for mGuard
Page 6: ...Innominate Security Technologies...
Page 32: ...mGuard rs4000 rs2000 32 Innominate Security Technologies I15007_en_02...
Page 74: ...mGuard rs4000 rs2000 3G 74 Innominate Security Technologies I15007_en_02...
Page 108: ...mGuard pci SD 108 Innominate Security Technologies I15007_en_02...
Page 142: ...mGuard centerport 142 Innominate Security Technologies I15007_en_02...
Page 156: ...mGuard delta 156 Innominate Security Technologies I15007_en_02...
Page 180: ...mGuard pci 180 Innominate Security Technologies I15007_en_02...
Page 196: ...mGuard blade 196 Innominate Security Technologies I15007_en_02...
Page 236: ...mGuard industrial rs 236 Innominate Security Technologies I15007_en_02...
Page 254: ...EAGLE mGuard 254 Innominate Security Technologies I15007_en_02...