Please read this user manual before using the device.
  Please keep this manual together with the device.

User’s Manual

2018/09 

Ver

0.06

VIEW600

Summary of Contents for VIEW600

Page 1: ...1 Please read this user manual before using the device Please keep this manual together with the device User s Manual 2018 09 Ver0 06 VIEW600...

Page 2: ...2...

Page 3: ...1 VIEW600 User s Manual...

Page 4: ...2...

Page 5: ...manual is only subject to the users who purchased this product View600 No part of this manual can be reproduced without any prior written permission from the publisher INNO INSTRUMENT INC Address E 2...

Page 6: ...Installation Safety warning and precautionary measures Operation warnings Transportation and storage Appearance overview Front panel The upper connection panel Back panel Charging method Test port Co...

Page 7: ...ll screen display key Parameter setting key OTDR key Event key Measurement key Loss Attenuation Reflectance Optical return loss Trace information key Start Stop key Save Open key OTDR setting key Comm...

Page 8: ...rview OPM Operation Chapter 7 VFL and Light Source Overview Visual light source operation light source operation Chapter 8 Fiber Microscope Overview Start fiber end inspection The function of fiber mi...

Page 9: ...ettings Standby and brightness Time Language WI FI Printer System maintenance Chapter 11 System Information System information Appendix Structure requirement Hardware interface requirement Software in...

Page 10: ...bol shows that this a relatively dangerous operation or has a certain harm Improper operation can result in mild or serious injury and property loss Safety signs used in the manual and machine The fol...

Page 11: ...que subi m me si le brouil lage est susceptible d en compromettre le fonctionnement Changes or modifications not expressly approved by the party responsible for compliance could void the user s author...

Page 12: ...data for this product INNO Instrument China Inc is not responsible for the loss of data Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect t...

Page 13: ...l light source VLS VFL option function With visual light source it can carry out the visualization inspection to find fiber bending and fiber rupture in dead zone OTDR test Based on Rayleigh scatterin...

Page 14: ...d light from visual light source can be captured by human eyes being able to directly locate fault location in fiber test dead zone or make fiber core calibration in multi fiber cable LS Stable light...

Page 15: ...absolute optical power meter or rela tive optical power loss through a span of optical fiber This module can measure optical power of multi wavelength Basic configuration Color TFT LCD AC adapter cha...

Page 16: ...6kg with battery Environment condition Operating environment Altitude 0 to 5000m Temperature 20 to 60 Relative humidity 0 to 95 Max wind velocity 15m s Storage environment temperature 10 to 50 Relativ...

Page 17: ...ed by its authorized technicians or engineers Please be careful when connecting battery adapter cable Do not pull the cable when you take it down from the socket but just hold the plug Please make sur...

Page 18: ...warm place from cold environment try to move it in a gradual warming way otherwise condensation will be produced in the inner of the device resulting in adverse effects to the device Please pack it w...

Page 19: ...enu Chapter 2 Installation Port description DC power connector Connect the adapter SMF port Testing port VIEW600 testing interface applied in OTDR and light source modules of VIEW600 VFL port Visual l...

Page 20: ...al fiber depends on the testing application while the number of the test port depends on the mea sured wavelength Follows are some universal connecters FC SC in use for VIEW600 Procedures for cleaning...

Page 21: ...he fiber jumper fiber connector and connect it to the testing port Clean the fibers to be tested Connect the fiber jumper with the tested fiber Connect VFL 2 5mm general adapter is configured to the v...

Page 22: ...Connect fiber inspection probe fiber microscope Connect with external fiber end inspection probe from USB interface Follows are the process to connect the visual light source Open the cover of USB po...

Page 23: ...ng picture Power off Press and hold the power key until the screen of shutdown appears grey logo Note Under any circumstance can you press and hold the power key more than ten seconds to force shutdow...

Page 24: ...detail information File copy As the following picture shows after inserting external storage device you can check the path of external storage device it in file management interface and then you can e...

Page 25: ...function is enabled If not a pop up message will appear on the screen as shown in the following picture OTDR Module Chapter 4 OTDR Module After loading OTDR and turn on the device please click OTDR i...

Page 26: ...key 21 Event key 22 OTDR key 1 Move cursor key 2 Move trace key 3 Partial amplification key 4 1 1 trace recovery key 5 Shortcut key for Trace amplification 6 Shortcut key for Trace shrink 7 Full scre...

Page 27: ...be it is not installed in some devices Move trace key Move cursor key After Clicking the Move cursor key you can change the position of the cursor on the screen by touching on the trace Move trace key...

Page 28: ...cation key and then click the screen to select the area of trace displayed This area will be amplified and displayed on trace display small screen interface 1 1 trace recovery key As shown in the foll...

Page 29: ...ce vertically Picture2 Full screen display key Click the Full screen display key to display the trace in full screen where the OTDR event measurement and trace information are shown Click this key aga...

Page 30: ...The Measurement menu is shown as follows The Trace Info menu is shown as follows Parameter setting key The wavelength distance range pulse width and average time can be set on the interface of measur...

Page 31: ...loss Sum can be shown Please refer to Section4 11 1 for Loss Please refer to Section4 11 3 for Reflectance Please refer to Section4 11 2 for Attenuation Cumulative Loss Sum It refers to the total los...

Page 32: ...combination Multiple reflection events appear together Echo Echo or return wave phenomenon appear Reflection event echo possible to occur Echo event possible to occur Macro bend event loss Attenuatio...

Page 33: ...measure the degraded signal strength for RBS Ray leigh backscattering caused by certain event Both reflective and non reflective event can cause event loss There are two algorithms on View600 Click L...

Page 34: ...o point analysis method the average measurement value can be gained by LSA The higher the noise level is the more reliable the LSA will be But when events such as ORL happen between two marker lines L...

Page 35: ...ine A and marker line B 2 Total ORL between start point of fiber span and the end point of fiber span Only the ORL of the single mode fiber can be calculated In real time mode the value of the ORL may...

Page 36: ...n in the picture click Start key to begin measuring and click Stop to stop measuring Save Open key On Save open interface you can carry out the operation of loading reading sav ing or clearing the mea...

Page 37: ...naming Identification and Clear trace in the Save file menu Save trace As the following picture shows the selected trace can be saved if Save trace icon is clicked Save to You can click Save to key t...

Page 38: ...ting Auto naming key And then you can set the file name file format and the modes of sorting files Picture 1 Picture 2 Identification Enter the Identification menu from the Save file menu after select...

Page 39: ...ked Picture 1 Picture 2 Open file As shown in the picture click open file select the file and then click Open to open the file OTDR setting key As shown in the picture click OTDR set key to enter into...

Page 40: ...the loss between these 2 lines Loss A loss B Introduction about application option a Light check Before setting the measurement please check if there is com munication light other light except the tes...

Page 41: ...whether to switch to the Event menu after OTDR measurement and event analysis completed 5 Show the selected Sets whether to only display the active trace of the mea sured fiber at a selected wavelengt...

Page 42: ...n Sampling Rate HR In this mode more signals are collected measurement distance is more accurate but the sampling and analysis are slower in speed 3 Unit Conversion 3 types of unit are available on Vi...

Page 43: ...Launch fiber and receive fiber The beginning of the link under test will be moved back according to the distance setup when launch fiber length is set The end of the link under test will be moved for...

Page 44: ...ance you have defined can revert to the default values immediately when you click Default key User definable range Picture 1 Picture 2 Custom time You can set the measurement time as needed And the va...

Page 45: ...hat a piece of PDF file has been created in the default directory Picture 1 Picture 2 Save as key You can click the Save as key to enter the Save as menu where you can edit the file name file format o...

Page 46: ...shown on the picture you can click Next to switch the trace and its information the file name file format or select the file to the USB Picture 1 Picture 2 Return key If you want to exit from the curr...

Page 47: ...the main menu interface then operate other modules Display screenshot key As shown on picture1 Display screenshot can be enabled to display the com plete trace to facilitate customer s macroscopic ob...

Page 48: ...resolution All these functions described above can be realized only by pressing one key SOLA operation In this device the module is interchangeable as need The corresponding SOLA module should be loa...

Page 49: ...h wavelength on the optical fiber link will be shown on the SOLA interface Line loss It refers to the total loss of the fiber link measured Return Loss it refers to the ORL on the whole fiber link SOL...

Page 50: ...Save Open menu Enter the Save Open menu by clicking the Save key as shown in the following picture Save SOLA Save the trace of SOLA file format to the default directory Save to USB Save the file to t...

Page 51: ...e name of the file and select PDF report and SOLA as a file format Clear SOLA If you click the Clear SOLA the file name and trace displayed will be cleared together Open File You can open the saved SO...

Page 52: ...Backscattering dB it refers to the RBS of the trace The reflectance and ORL of the trace will vary depending on this parameter Chapter 5 SOLA Management As shown in the picture you can enable managem...

Page 53: ...s to judge whether the elements are passed or failed For example When you want to modify max splice loss directly click the value in intersection and then you will see a pop up box for value input on...

Page 54: ...ch Fiber and Receive Fiber as shown in the following picture Chapter 5 SOLA Make report Select the make report tab to save the current SOLA file in PDF format Save as You can click the Save as key to...

Page 55: ...Chapter 7 VFL and Light Source 53 Chapter 5 SOLA Screenshot The displayed image can be captured via the screenshot key in the SOLA menu...

Page 56: ...multi wavelength It can be operated easily Reference value OPM onView600 you can set the reference value in the OPM interface You can set a value as a reference to calculate the current value of opti...

Page 57: ...test dead zone or make fiber core calibration in multi fiber cable The visual light source in View600 can launch two types of light source continuous light source CW light and 2Hz blink light Stable...

Page 58: ...ce icon from Home menu to enter into the visual light source interface as the following picture shows Click CW or 2Hz to select and switch light source The name that displayed on the message bar of th...

Page 59: ...blink 2KHZ blink by tapping on the lower left side of the screen after that tap open key to open the invisible light source Turn off light source please tap on close key on the right side Warning The...

Page 60: ...iber end inspection After connecting the fiber inspection probe click Fiber Microscope on VIEW600 main interface to enter into the inspection interface Please refer to picture 8 1 Chapter 8 Fiber Micr...

Page 61: ...sult and identification screenshot real time video function is a premise of save After connecting successfully the device you cannot enable save function until screenshot real time soft key changes to...

Page 62: ...results in the form of tables Identify function is used to set related information displayed the contents of which are user definable Check the preserved image Click the file management icon on the ma...

Page 63: ...e sdcar and usb Start file management Click File Manager on main interface of VIEW600 to enter into the file menu File manager function There are following items in this menu such as File Name Date an...

Page 64: ...the File Type Operating Steps a Click FILE TYPE to select the file type needed to be copied b Click and access to the root directory sdcard usb directory c Click PASTE after selecting subdirectory or...

Page 65: ...Click and access to the root directory sdcard usb c Select folder or files to execute DELETE RENAME key It can rename folder file and file format Operating steps a Click FILE TYPE to select the file...

Page 66: ...steps a click and access to the root directory sdcard USB directory b Click NEW FOLDER to enter into the input interface and then input the folder name then press ENTER to create a folder successfully...

Page 67: ...ce Functions of system settings There are functions such as standby and brightness time language WIFI printer and system maintain in VIEW600 system setting menu Standby and Brightness 1 Backlight brig...

Page 68: ...n is used to set the languages displayed on the screen Chapter 10 System setting Time You can use time function to set the time that is displayed on the device You can select Import Profile to configu...

Page 69: ...ult printing function after you select the Printer key You can select from two printer modes i e Network printer and USB printer Click Refresh list after the device connected with the printers and the...

Page 70: ...eration steps Insert the USB with file to be updated and power adapter to VIEW600 port respectively Click System maintain on system setup interface Click Upgrade then it will show upgrade notice and t...

Page 71: ...icture this interface displays the information about the products and manufacturer Chapter 11 System Information If you select to pay by installment the corresponding information will appear on the sc...

Page 72: ...p operation Blink Low electric quantity off Power off Names of buttons Quantity POWER 1 HOME 1 Keys 11 Hardware interface requirement DC INPUT Power port USB port 2 pieces Save data and connect the fi...

Page 73: ...le Technical index Value OTDR Please refer to the parameters of OTDR module purchased Sola Please refer to the parameters of OTDR module purchased VFL module Operating wavelength 650 20nm Power 20MW I...

Page 74: ...bending radius Cable bending radius refers to the stress load that cable suffered free bend refers to the admissible diameter for it lies under no burdened state Cable module The kind of cable install...

Page 75: ...ed light wave can transmitted in optical waveguide it is the differential equation eigenvalue featured in waveguide There is only one module which can transmit in single mode optical fiber called basi...

Page 76: ...e module constituted by the materials which can protect the optical fiber and resist to machine or environment damage P Plug in board Network devices in the bracket such as OTDR or the switches Photoe...

Page 77: ...in system when transmission happens Telecom cabinet TC It is an enclosure space placed by cross linked fiber terminal and telecom settings Equipment cabinet is regarded ascross link by main wiring an...

Page 78: ...of the device can only be carried out by qualified maintenance technicians Please contact the engineers of INNO Instrument You can also consult any question through the following website www innoinstr...

Page 79: ...ble Source Output Power 0 04 20 15min dBm OTDR VIEW620 4 VIEW630 1 VIEW630 2 VIEW630 3 VIEW630 4 VIEW630 5 VIEW630 6 Dynamic Range 850 1300 1310 1550nm 1310 1550 nm 1310 1550 1625nm 1310 1550 1625nm l...

Page 80: ...Product specifications and models are subject to change without notice The End...