background image

IN2013HR Operation Manual - V1.0  12/05/00                                             

©2000  -  INLINE, Inc. 

 

OUTPUT SIGNAL FORMAT SELECTION

 

Output Format:  Automatic Sense Mode  (Dipswitch 5 = 1) 

In factory default configuration, the IN2013HR automatically senses the number of cables connected 
to the output BNC connectors and selects an appropriate output signal format. LED indicators located 
next to the V/Sync, H/Comp Sync and Green output BNCs (on the back of the interface) provide clear 
visual confirmation of the current output sync format.  In order for output format auto sense circuit to 
operate, dipswitch 5 on Switch Bank 1 must be set to 1. 

 

 

Number of Cables Connected to Output 

Output Format 

(3) Cables connected to RGB BNCs 

RGsB 

(4) Cables connected to RGBS BNCs 

RGBS 

(5) Cables connected to RGBHV BNCs 

RGBHV 

 

Output Sync Format :  Manual Mode  (Dipswitch 5=0) 
For some applications, you may wish to force the interface to operate in a specific output format.  
To set the output sync format manually, you must first disable the auto sense circuit by setting 
dipswitch 5 on Switch Bank 1 to 0.   Next, set dipswitches according to the table below to select 
the desired output format. 
 

Output Format 

Dipswitch Settings  

(Switch Bank 1) 

RGBHV (Factory Default) 

2 = 0 
3 = 1 
5 = 0 

RGBS 2 

3 = 0 
5 = 0 

RGsB 2 

3 = 1 
5 = 0  
7 = 1 

Composite Monochrome on Green BNC 

2 = 1 
3 = 1 
5 = 0  
7 = 0 

 

INPUT SIGNAL FORMAT SELECTION

 

The IN2013HR is set at the factory for automatic operation with SUN and most SGI computers 
(*dipswitches 8 / 9 / 10 off).  For other computers or signal formats, carefully set dipswitches 8, 9 and 
10 as indicated in the chart below

.

 

 

INPUT SIGNAL CONFIGURATION - SWITCH BANK 1 

DIPSWITCH SUN 

RGBS* 

SUN 

RGBHV 

SGI / NeXT 

RsGsBs 

SGI 

RGBS 

SGI 

RGBHV 

IBM 

POWER 

PC 

8 0 

9 0 

10 0 

1 1 

0 0 

                                       *Factory Default Settings 

Summary of Contents for IN2013HR

Page 1: ...IN2013HR HIGH RESOLUTION VIDEO INTERFACE FOR 13W3 WORKSTATIONS IN20 1 3HR OPERATION MANUAL...

Page 2: ...n Instalacion E Instrucciones de Seguridad Modelos Sin Interruptor La conexi n debe ser instalada cerca del equipo y debe ser accesible Para Todos Los Modelos Dentro de la unidad no hay partes para re...

Page 3: ...omposite Monochrome as required by the display device cabling and video routing system PRODUCT FEATURES Universal Compatibility for Graphic Workstations with 13W3 Video Ports Factory set for automatic...

Page 4: ...BM PowerPC NeXT and virtually any other graphic workstation that outputs analog video through a 13W3 female connector Input signal compatibility parameters are Video Signal Analog RGB Video Connector...

Page 5: ...at Computer Input Selection Dipswitch Chart Workstation Input Signal 8 9 10 Dipswitch Setting Switch Bank 1 RGBS most common 000 Composite Sync on pin 5 SUN RGBHV 101 Hor sync on pin 6 Vert sync on pi...

Page 6: ...Emulation Dipswitch Chart provided on page 9 Check the Monitor Emulation chart and dipswitch settings carefully Any improper setting of the emulation dipswitches may lead to improper operation and cou...

Page 7: ...5 2000 INLINE Inc IN2013HR Operation Manual V1 0 12 07 00...

Page 8: ...e sharpness control should usually be placed at the minimum setting to avoid over peaking The sharpness control is located between the gain control knob and the local monitor output port Using the IN9...

Page 9: ...ngs SWITCH 1 For most installations the IN2013HR will be operated in the factory default mode and will not require any changes to the dipswitch settings The factory default settings are SWITCH 1 Dipsw...

Page 10: ...Sync Format Manual Mode Dipswitch 5 0 For some applications you may wish to force the interface to operate in a specific output format To set the output sync format manually you must first disable th...

Page 11: ...play device If you are not using a local monitor but need to emulate a specific mode locate your workstation type and desired mode in the chart at the bottom of the page If you are not sure of the exa...

Page 12: ...econds Video Gain Terminated Variable Control Adjustable from 7 30 voltage decrease to 1 3 30 voltage increase Sync Signal H V and S 5V unterminated and 2Vp p 75 ohm terminated Sync on Green 0 3 Vp p...

Page 13: ...able Troubleshooting Problem There is no image on the display device Solution 1 Make sure that the IN9230 IEC power cable is securely plugged into the unit and the A C source Solution 2 Make sure the...

Page 14: ...e output image is missing a color Solution The RGB cable may be damaged defective Try switching connections on the output to verify that the bad color s cable is OK Example If there is no red try runn...

Page 15: ...ticular purpose all of which are expressly disclaimed The information in this manual has been carefully checked and is believed to be accurate However INLINE Inc assumes no responsibility for any inac...

Reviews: