Inkel IRM-816 Operation Manuals Download Page 4

REMOTE MICROPHONE STATION 16CHANNEL   

4

IRM-816

Safety Instruction

1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including

amplifiers) that produce heat.

9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one

wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third
prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for
replacement of the obsolete outlet.

10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the

point where they exit from the apparatus.

11. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus.

When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over. 

13. Unplug this apparatus during lightning storms or when unused for long periods of time. 
14. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in

any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the
apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

Information for Users on Collection and Disposal of Old Equipment and used Batteries

These symbols on the products, packaging, and/or accompanying documents mean that used electrical
and electronic products and batteries should not be mixed with general household waste. 
For propertreatment, recovery and recycling of old products and used batteries, please take them to
applicable collection points, in accordance with your national legislation.
By disposing of these products and batteries correctly, you will help to save valuable resources and
prevent any potential negative effects on human health and the environment which could otherwise arise
from inappropriate waste handling.
For more information about collection and recycling of old products and batteries, please contact your
local municipality, your waste diposal service or the point of sale where you purchased the items.

Information on Disposal in other Countries outside the European Union

These symbols are only valid in the European Union. If you wish to discard these items, please contact
your local authorities or dealer and ask for the correct method of diposal.

Note for the battery symbol (bottom two symbol examples):

The sign Pb below the symbol for batteries indicates that this batteries contains lead.

Summary of Contents for IRM-816

Page 1: ......

Page 2: ...L 2 IRM 816 Welcome 3 Unpacking 3 Before Use 3 Safety Instruction 4 Operation 5 Features 5 Front Panel 6 Rear Panel 7 Precaution for RACK Installation 8 RACK Connection 8 Block Diagram 9 Specification 10 Service and Warranty 11 Contents ...

Page 3: ...please keep them If you ever need to return the unit to INKEL PA or an authorized service center you should use only the original factory packing Welcome WARNING TO PREVENT FIRE OF ELECTRIC SHOCK HAZARD DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE Unpacking To insure proper use of this product please read owner s manual carefully and keep this manual in an easily accessible place for future refe...

Page 4: ...l servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped Information for Users on Collection and Disposal of Old Equipment and used Batte...

Page 5: ...n IRM 816 with a power switch The power LED will be illuminated 2 If announcement is to be broadcasted to one of the sixteen loudspeaker zones press a corresponding channel switch The selected channel switch LED will be illuminated 3 If announcement is to be broadcasted to all sixteen loudspeaker zones press ALL call switch The ALL call switch LED will be illuminated 4 Press a CHIME switch for pre...

Page 6: ...ition of this unit and if power is supplied this LED is illuminated while if power is blocked it is out If power switch of No 5 is turned on this LED is illuminated while if it is turned off then LED is out 5 POWER ON OFF SWITCH This switch turns the power of this unit and its power source is DC 24V 6 CHIME VOLUME This volume controls CHIME level if you turn it clockwise the volume is increased wh...

Page 7: ...n you want to announce press this switch so that unnecessary noise is not occurred When the switch is on LED GREEN is illuminated 2 4 3 1 1 SPEAKER CONTROL TERMINAL HOT COM These terminal controls zone speaker It is connected to remote 1 remote 2 terminal of MATRIX our model IPX 8116 or EMERGENCY CONBINATION our model IEC 8216 2 LINE OUTPUT TERMINAL As output signal terminal of this unit it is con...

Page 8: ...D 8329 Precaution for RACK Installation Turn off the power on the right side and connect or install it Avoid moisture and install it on the place where has good ventilation If use other MIC model not offered MIC by ours use only PHANTOM over than 18V DC Be sure about polarity before connecting DC power Be sure about HOT COLD and GND before connecting LINE OUT of this unit ...

Page 9: ...REMOTE MICROPHONE STATION 16CHANNEL IRM 816 9 Block Diagram ...

Page 10: ...uency Response 3dB MIC 100Hz 15KHz AUX 20Hz 20KHz T H D MIC Less than 0 5 AUX Less than 0 2 S N MIC Better than 50dB AUX Better than 80dB Speaker Control Terminal Switch 16CH Operation Temperature 10 40 Storage Temperature 20 60 GENERAL Power Source DC 24V Weight 1 2kg Without Microphone Dimension 245 W 72 H 180 D mm Specifications and design are subject to change without notice ...

Page 11: ...w inkelpa com WARRANTY INFORMATION Warranty terms and conditions vary by country and may not be the same for all products Terms and conditions of warranty for a given product may be determined first by locating the appropriate country which the product was purchased in then by locating the product type To obtain specific warranty information and available service locations contact INKEL PA directl...

Page 12: ......

Reviews: