Inis Mor MK2 Boiler stove
14
the flow to the central heating circuit
set at 90 degrees centigrade to start
the pump in the event the low limit stat
fails.
Initial firing pre-check
Before firing the stove for the first
time points to check for after installa-
tion are,
1.
Inspect the ash-pit and firebox of
the stove to ensure all the vari-
ous grate components and fire
bricks did not become dislodged
during transport and fitting.
2.
Check that the chimney is sound
and clear.
3.
The room has vents as described
above.
4.
That all the sealing joints have
had time to set properly.
5.
That all door seals etc. are cor-
rect and present.
6.
That the damper is operational and
working properly.
7.
That all installation guidelines
have been adhered to.
8.
That all local national and Euro-
pean guidelines and laws have been
followed.
Initial firing
The first fire should be quite small to
ensure prompt extinguishing of the fire
in the event of a problem. The user man-
ual contains details on how to start a
fire in the stove.
Issues to check for once the stove is
alight are,
1. That no fumes are being emitted into
the room,
2. That a window is open in the room to
remove fumes from the paint on the stove
being emitted. Please see the paint cur-
ing procedures in the user manual.
3. Check that all the radiators etc. are
heating and that there is no air present
in the system.
4. As this is a high output boiler
stove, adjustment of the pump speed to a
higher setting may be necessary to avoid
intermittent boiling of the boiler at
high outputs.
Commissioning and hando-
ver.
Once the initial fire and the correct
operation of the stove have been estab-
lished, the user must be instructed on
the proper operation and maintenance of
the stove.
Answer any queries or issues the user
may have and seek advice from Inis
Stoves with regard to any issue you may
not be in a position to answer.