Chapter 1

GENERAL

INFORMATION

1-1

Manufacturer's details

Manufacturer:

INIM Electronics s.r.l.

Production plant:

Via Fosso Antico - Centobuchi
63033 Monteprandone (AP) - Italy

Tel:

+39 0735 705007

Fax:

+39 0735 704912

e-mail:

[email protected]

Web:

www.inim.biz

Any persons authorized by the manufacturer to repair or replace the parts

of this system, hold authorization to work on INIM Electronics brand

devices only.

1-2

Description of the product

and various models

Description:

Intrusion control panel

Models:

SmartLiving 505
SmartLiving 515
SmartLiving 1050
SmartLiving 1050L
SmartLiving 10100L

Year of manufacture:2009
The following table describes the main features of the 4 models.

Table 1: 

Control panel - Main Features

SmartLiving intrusion control panels

505

515

1050

1050L

10100L

Total terminals

5

15

50

100

Terminals on panel

5

10

Terminals on panel configurable as inputs

5

10

Terminals on panel configurable as 

Rollerblind/Shock

2

Terminals on panel configurable as outputs

0

5

Total zones

10

30

100

200

Relay outputs on panel motherboard

1

Open-collector outputs on panel 

motherboard

2 (150mA)

2 (500mA)

Partitions

5

10

15

JOY and nCode/G keypads

5

10

15

FLEX5 Expansions

5

10

20

40

nBy Readers

10

20

30

Transceiver (Air2-BS100)

1

Codes

30

50

100

Digital keys and keyfobs

50

100

150

Timer

10

Recordable events

250

Summary of Contents for snartliving

Page 1: ...GameOver USER S MANUAL S E C U R I T Y S Y S T E M S...

Page 2: ...applies only to defects in parts and workmanship relating to normal use It does not cover damage arising from improper maintenance or negligence damage caused by fire flood wind or lightning vandalis...

Page 3: ...13 2 6 Keys 15 2 7 Multi system access 16 2 8 Telephone functions 16 2 9 WEB e mail functions 17 Chapter 3 Shortcuts 18 3 1 Keypad shortcuts 18 3 2 Shortcut with code 19 3 3 Key and Reader shortcuts...

Page 4: ...4 User s Manual 5 15 Using the SmartLAN G 35 Appendix A Technical terminology and Glossary 36 Appendix B Shortcuts at default 40 Appendix C Fault signals 41 Notes 43...

Page 5: ...ving 1050 SmartLiving 1050L SmartLiving 10100L Year of manufacture 2009 The following table describes the main features of the 4 models Table 1 Control panel Main Features SmartLiving intrusion contro...

Page 6: ...up and programs the entire security system in accordance with the purchaser s requirements and in respect of the safety laws in force As the only individual in contact with system users it is the ins...

Page 7: ...in the operations you must undertake nBy readers 2 versions available nBy S wall mount and By X flush mount allow you to access and control the system Although these devices are not as flexible as key...

Page 8: ...ice board allows each event to be associated with a message Voice digitizing and compression allow the signal to be transmitted in data packets over the bus to recipient keypads where it is announced...

Page 9: ...epresents the partition concerned will blink The right side of the second line shows several icons which provide visual information regarding the system Their meanings are described in the following t...

Page 10: ...atus when the keypad partitions disarm Any auto bypassable zones will be shown in white on black background Note Case D is discernible from case B in the fact that in case B the red LED on the keypad...

Page 11: ...x A Technical terminology and Glossary of enabled partitions 18 23 20 08 2008 DASIDASI Press simultaneously Table 4 Keypad LEDs LED Red Yellow Blue Green OFF no light All the keypad partitions are dis...

Page 12: ...aders are usually located near the main entry exit points of the protected building These devices allow system access to valid keys only The system readers are capable of recognizing the customized pe...

Page 13: ...t one Reader partition is armed Slow blinking ON 0 5sec OFF 0 5sec The reader partitions are disarmed Alarm tamper memory on at least one of the reader partitions or system tamper memory The scenario...

Page 14: ...activated deactivated manually After accessing the Outputs ON OFF section User Menu the user can activate deactivate the duly programmed outputs Menu sections These are the authorized User menu secti...

Page 15: ...user will be unable to access the system at all other times Patrol attribute This option is usually enabled on keys used by security personnel or night watchmen who must patrol the protected premises...

Page 16: ...rs via a voice dialer The SmartLiving control panel also accepts commands over the phone Commands can be sent during calls to from the control panel after valid PIN entry on the telephone keypad The c...

Page 17: ...le of containing a direct link to a website or to an IP addressable device such as an IP camera and an attachment document file For a description of a typical e mail format refer to paragraph 5 15 1 e...

Page 18: ...affect all the keypad partitions 3 Code users only Press the respective key from to then enter a valid code the shortcut will activate after code recogni tion The shortcut will affect the partitions c...

Page 19: ...e followed by 3 Press the number key which corresponds to the required shortcut 3 3 Key and Reader shortcuts 3 3 1 nBy S and nBy X Reader shortcuts Hold a valid key in the vicinity of the reader a ser...

Page 20: ...artition are armed the LED sequence will start at point 6 3 3 3 Keyfob shortcuts To activate the keyfob shortcuts programmed by your installer assigned to keys to simply push the button which correspo...

Page 21: ...MAX keypad at address 1 Each JOY MAX keypad has a memo box for user memo recording playback This handy function will allow you to leave messages for other users who have access to the keypad refer to...

Page 22: ...ccessing the User Menu however this chapter describes the pro cedure via menu and provides the visual information relating to the sections described at point 1 in paragraph 2 5 1 Accessing the User Me...

Page 23: ...rio via Command Zone Under normal circumstances a command zone comprises a mechanical key lock or callpoint which activates an electrical contact wired to the command zone In accordance with how the c...

Page 24: ...d activate one of the following option using the key Stop alarms Clear call queue DeleteAlarm mem The following shortcuts activate the associated commands Shortcut n 2 Stop alarms Shortcut n 3 Clear c...

Page 25: ...econds will be signaled by a counter and a progress bar on the display If you wish to interrupt the record playback operation manually press otherwise it will end automatically when the pre set time o...

Page 26: ...sed for system control purposes Dialer a deactivated disabled dialer cannot send voice or digital calls However if duly programmed it will be able to manage incoming calls Answerphone function if acti...

Page 27: ...tatus of some of the system peripherals and elements The Events log Alarms log Faults log and Arm Disarm ops allow you to view the start and end of the corresponding events in chronological order The...

Page 28: ...iew section are Shortcut n 28 accesses View Events log Shortcut n 29 accesses View Alarms log Shortcut n 30 accesses View Faults log Shortcut n 31 accesses View Arm Disarm ops Shortcut n 32 accesses V...

Page 29: ...status empty No alarm events saved to memory empty No tamper events saved to memory Zone in alarm status Zone unbypassed empty Zone not in test status Alarm event saved to memory Tamper event saved to...

Page 30: ...structions described in Method 1 via Reader Hold a valid digital key in the vicinity of the reader until the reader LEDs or display indicates Activate outputs macro n 5 or Deactiv outputs macro n 6 ov...

Page 31: ...he level of brightness of the display backlight and LEDs during standby status Contrast allows you to adjust the black white contrast Volume allows you to adjust the buzzer volume 3 levels available O...

Page 32: ...N again using keys to then press to save Method 2 Access the Change PIN section of the User Menu by means of a valid PIN Follow the instructions described in Method 1 5 10 Teleservice request This com...

Page 33: ...be activated over the phone only The listen in function allows you to eavesdrop on the protected premises through the microphones of JOY MAX keypads which have at least one partition in common with t...

Page 34: ...ce in order the descriptions of the partitions the entered PIN is assigned to and their current armed disarmed status 5 14 Commands over the phone 5 14 1 Panel to user calls Your installer will instru...

Page 35: ...code CODE 001 KEYP 005 PARTITION 001 The first part of the e mail shows the date and time of the event when saved to the events log and any relative details Access with valid code entry saved to log O...

Page 36: ...cipient can type in a valid PIN enabled for over the phone control and access the authorized functions ANSWERPHONE User operations on one or more partitions These generally indicate also the status of...

Page 37: ...ons from a keypad the events log will show description of the event Arm request description of the code and partitions involved description label of the keypad involved date and time of the request EV...

Page 38: ...e status of a partition as requested by the user The user can carry out the following operations Disarm this operation disables the partition completely In this way none of the zones belonging to the...

Page 39: ...es However any alarm events that occur will be saved to the events memory If zones are not operating properly the Test option will allow the installer to check them without the risk of generating fals...

Page 40: ...le timers Accesses the User Menu section Activations Timers 9 Voice menu Plays a recorded voice message which announces the shortcuts assigned to the number keys User code 27 Enab auto arm Accesses th...

Page 41: ...or disconnected Low battery The control panel backup battery is running low or is not connected properly Call your Installer company Mains failure Mains failure The primary power source 230 Vac has f...

Page 42: ...42 Fault signals User s Manual DCMUINE0SLIVING R260 20090923...

Page 43: ...User s Manual 43 Notes...

Page 44: ...via Fosso Antico Loc Centobuchi 63033 Monteprandone AP ITALIA Tel 39 0735 705007 Fax 39 0735 704912 info inim biz www inim biz Azienda certificata ISO 9001 2000 ITALY...

Reviews: