SmartLink-P
PSTN dialler
Installation and
programming
manual
PATENT PENDING
Page 1: ...SmartLink P PSTN dialler Installation and programming manual PATENT PENDING...
Page 2: ...tten authorization from INIM Electronics s r l All rights reserved Directive 1999 5 CE R TTE compliance Hereby INIM Electronics s r l declares that SmartLink P is in compliance with the essential requ...
Page 3: ...description 12 4 1 Technical specifications 13 Chapter 5 Internal components 14 5 1 Terminal board 14 5 2 LED 15 Chapter 6 Device features 16 6 1 General features 16 6 2 Application 16 6 3 Intrusion...
Page 4: ...sion control panel 36 8 9 Programming event generated actions 37 8 10 Programming periodic events 44 8 11 Remote control of SmartLink P via DTMF tones 45 Appendix A Wiring diagram of an intrusion con...
Page 5: ...reports Contact ID protocol over the landline to Alarm Receiving Centres and customized voice messages to contact numbers This device greatly enhances the security of control panels which are not equ...
Page 6: ...r reproduced unless expressly authorized in writing by INIM Electronics s r l in particular the parts regarding the device specified in 2 7 Device identifier INIM Electronics s r l shall not be respon...
Page 7: ...vice parts Note The detached notes contain important information about the respective text Attention The attention prompts indicate that total or partial disregard of the procedure could damage the co...
Page 8: ...t its option repair or replace any defective products Improper use that is use for purposes other than those mentioned in this manual will void the warranty For the full details and conditions regardi...
Page 9: ...EC 61340 5 1 ed IEC TR 61340 5 2 2 9 2 Setting up the system In order to provide adequate protection and instructions for proper use security professionals Installers and maintenance test technicians...
Page 10: ...storage 5 40 C operating temperature 3 3 Unpacking the device The goods must be unpacked with care All waste packaging materials must be disposed of in compliance with the local laws and bylaws in for...
Page 11: ...Installation and programming manual Device management 11 Figure 2 SmartLogos60 and Switching power supply battery charger IPS12015DT...
Page 12: ...on of parts A Terminal board B LED indicators C RS232 serial port connector D Buzzer E Battery connectors F Firmware version label G Tamper microswitch H SmartLogos 60 voice board connector I Wall mou...
Page 13: ...rocess described in Chapter 7 Installation 4 1 Technical specifications Power supply 13 8Vdc 10 PCB operating current draw 40 mA in standby 70 mA maximum Maximum current draw on terminal AUX 400mA Max...
Page 14: ...d reference for signals on terminals Negative power 5 IO1 Input Output terminals 13 8Vdc 150mA current draw for each terminal 6 IO2 7 IO3 8 IO4 9 IO5 10 OPEN Tamper protection Refers to the tamper mic...
Page 15: ...also be used 5 2 LED The SmartLink P board provides three status LEDs with the following meanings Figure 5 LED Note All three LEDs will blink during the programming phase LED Colour ON Blinking OFF 1...
Page 16: ...y local remote control activates sounder flasher signaling manages voice calls and Contact ID reports Digital dialer Contact ID Sends event associated Contact ID reports to alarm receiving centres and...
Page 17: ...s 6 5 Voice dialer The Voice dialer function sends pre recorded voice messages The voice dialer function requires installation of the SmartLogos60 voice board accessory item 6 6 Remote control via DTM...
Page 18: ...2 PWR and PWR 5 Connect the battery 12V 1 2Ah to the Red wire 1 and Black 2 table on page 12 E and locate it in its housing Attention Be sure the polarity is correct 6 Connect the serial cable and car...
Page 19: ...ble to connect the telephone line to terminals 15 and 16 and all other telephone devices to terminal 13 and 14 7 2 3 Earthing Terminal 12 must be earthed Danger This operation is telecommunications ne...
Page 20: ...l board 7 2 8 Connecting the RS232 PC serial link Connect the RS232 cable to the respective connector on the SmartLink P board table on page 12 C The cable should be connected to the apparatus as show...
Page 21: ...e software can be downloaded from the INIM electronics Web address at www inim biz After installing the SmartLeague software contact the Web address to find out about new versions Internet connection...
Page 22: ...ters without actually being connected to the device Your service computer must be connected to the mounted powered up SmartLink P during the parameter downloading phase The connection cable must be lo...
Page 23: ...e updated information regarding software and firmware upgrades revised manuals instruction inserts and newsletters etc Note To change the Web address of the page and reconnection interval to the websi...
Page 24: ...reate a new solution select File New or open the current solution configuration of the system select File Open 3 To load the current parameters select Program Upload all three LEDs will blink during t...
Page 25: ...ata phone numbers for Contact ID reports and voice messages voice messages Caller ID codes 2 Configure the device parameters 3 Configure the inputs and outputs for intrusion control and normal applica...
Page 26: ...es the voice message feature You can create a group of event messages and a group of messages associated with the places the events may occur For example as illustrated you can select Msg4 Attempted T...
Page 27: ...r of the message 1 to 8 which you wish to record and wait for the confirmation beep 4 Wait for a second beep which signals the start of the recording and record the message maximum 10 seconds You can...
Page 28: ...t calls to alarm receiving centres Parameter Description Note Installer code This is the access code that SmartLeague uses during communications with the device User code This is the user access code...
Page 29: ...rusion control panel is armed it is the time the user has to disarm the SmartLink P after violating a delayed input If the user does not disarm the intrusion control panel before the delay ends the Sm...
Page 30: ...econd call and will be ready to accept DTMF commands Only if Enable PSTN answerphone option has been selected Program the fax machine or modem to answer after the set Number of rings Number of rings N...
Page 31: ...selected incoming and outgoing calls will not generate visual signals on the yellow LED This feature is a useful way of hiding intrusion panel generated communications from intruders Other parameters...
Page 32: ...lance resistors which determine the three threshold windows Each exceeded threshold generates an event which can be associated with an outgoing Contact ID report voice message or activation of outputs...
Page 33: ...igure event 16 Input 4 status 4 which is line shorted to ground of Output 2 to send a voice call and to toggle output 3 to ON status 3 Result the remote command will close output 4 to ground The statu...
Page 34: ...the respective check box Blinks 2Hz frequency 0 25 seconds ON an 0 25 seconds OFF Do not click on the check box if you want the LED to be solid Input Type Enabled only when the SmartLink P is used as...
Page 35: ...ot be necessary 5 Otherwise select Calibrate answer YES to the confirm request 6 Click on the value of the resistor used then select Ok SmartLink P compares the selected value and the current value on...
Page 36: ...e Inputs with the Delayed attribute will not generate the status change event during the programmed delay defined in the Intrusion control panel parameters table A series of slow beeps emitted by the...
Page 37: ...tions e g input signals and internal conditions e g low battery The events can generate the following actions Input 24h If 24h is not selected only Short circuit and Tamper will be monitored during pa...
Page 38: ...etting up the SmartLink parameters for the settings relating to the voice dialer such as call attempts message playbacks call confirmation and others 8 9 1 Delete event programming The event programmi...
Page 39: ...open columns containing the successive parameters will appear Double click to close no parameter has been set some parameters have been set Voice messages Check boxes corresponding to the voice messag...
Page 40: ...ontaining the successive parameters will appear Double click to close no parameter has been set some parameters have been set Protocol class ContactID protocol class The event protocol class must be a...
Page 41: ...select default Contact ID reporting protocol 2 customize the Codes to central station requirements 3 print the Contact ID table using File Print Programming the SmartLink P as an intrusion control pa...
Page 42: ...ble output See paragraph 8 7 Programming the Inputs and Outputs IN OUT Parameter Description Note Outputs Folder containing the output activation parameters Double click to open columns containing the...
Page 43: ...r call queue If selected this event will interrupt the ongoing call and cancel any event generated calls For example this option is useful when users want to stop unnecessary calls generated by false...
Page 44: ...e examples are only suggestions The programmable events are fully customizable Parameter Description Note Periodic event The first Periodic event will be generated in accordance with the set date and...
Page 45: ...rm voice call from SmartLink P you will automatically access DTMF mode which in the case of the flood alarm call will allow you to turn off the water supply at the mains 8 11 1 Sending the DTMF tone s...
Page 46: ...2 Select the output by pressing the respective key 1 to 5 If the selected output is associated with and Inhibit event you will hear an error signal bop and it will be necessary to select another outp...
Page 47: ...Installation and programming manual Wiring diagram of an intrusion control panel 47 Appendix A Wiring diagram of an intrusion control panel...
Page 48: ...OFF Outputs programming IO4 Type Bistable Polarity normally open IO5 Already programmed by the selected parameter Enable intrusion control The diagram illustrates an application with Two DEOL zones fo...
Page 49: ...ground The fifth terminal IO5 is a normally open bistable output which signals PSTN line down and Low battery conditions All events saved to Events log Enabled Parameters Instant signaling of PSTN lin...
Page 50: ...Programming software Windows ambient SmartLink BG Reserve line generator and GSM network dialer in cream coloured casing SmartLink BGP Reserve line generator and GSM network and PSTN dialer in cream...
Page 51: ...Installation and programming manual Notes 51 Notes...