INIM Electronics Previdia Compact Manual Download Page 9

Configuration manual

Configuration

9

2.4

Access to the device modification menu

Once the Previdia Compact system has been configured it is necessary to set the parameters, or change the default
programming of the devices connected to the control panel, individually or in a group.

The Previdia Compact control panel provides a direct programming option on the control panel for its connected
devices and their logical groups (zones and output groups) without need of accessing the “Configuration” section
(

paragraph 2.3

). To access it, you must access the programming phase of the control panel (

paragraph 2.2

) and then

press the 

Modify

 button on the menu that appears on the screen.

The section you access will show Ia list containing the access buttons to the programming subsections::

• Zones (refer to 

paragraph 4.3

)

• Output groups (refer to 

paragraph 4.4

)

• I/O Lines (refer to 

paragraph 4.2

)

• Loop points (refer to 

paragraph 4.1

)

Icon

Function buttons

Display

Access to the configuration of the 

general parameters of the control panel.

Refer to 

paragraph 3.1

Access to the configuration of the 

general parameters of the Inim Cloud 

service.

Refer to 

paragraph 3.2

.

Access to the configuration of the 

extinction channel.

Refer to 

paragraph 3.10

Access to the configuration of the 

Ethernet network.

Refer to 

paragraph 3.3

Access to the configuration of the 

 network.

Refer to 

paragraph 3.4

Access to the configuration of the loops 

(loop 1 and loop 2).

Refer to 

paragraph 3.5

Access to the functions provided by the 

SD card.

Refer to 

paragraph 3.6

Access to the configuration of the inputs 

and outputs provided by the control 

panel terminals.

Refer to 

paragraph 4.2

Access to the configuration of the 

control panel access codes.

Refer to 

paragraph 3.8

Access to the configuration of the 

general parameters of the remote 

communicator.

Refer to 

paragraph 3.9

Access to the configuration of the 

power supply.

Refer to 

paragraph 5.1

Access level:3

Summary of Contents for Previdia Compact

Page 1: ...FIGURATION COMMISSIONING AND MAINTENANCE EN 54 2 EN 54 4 EN 54 21 EN 12094 1 ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL EXTINGUISHANT SYSTEM CONTROL PANEL ALARM TRANSMISSION AND FAULT WARNING ROUTING...

Page 2: ...en goods or claims by any other party caused by defective products or otherwise arising from the incorrect or otherwise improper installation or use of this product This warranty applies only to defec...

Page 3: ...figuring the Hornet network 13 3 5 Configuring the loops 13 3 6 SD card functions 16 3 7 Configuring the terminals 16 3 8 Configuring the users 17 3 9 Configuring the communicator 17 3 10 Configuring...

Page 4: ...4 Table of contents Fire detection and extinguishant system...

Page 5: ...scribes the procedures for the configuration commissioning and maintenance of the Previdia Compact fire detection system 1 2 1 Graphic conventions Following are the graphic conventions used in this ma...

Page 6: ...ctivate alarm signalling when an early warning condition is running Level 2 Authorized users this access level is for the system supervisors and is for authorized personnel who are adequately instruct...

Page 7: ...languages is required a mandatory main language and an optional second language The control panel screen will be as follows In the case of faults or other types of events the latter will be shown on t...

Page 8: ...cess the programming phase of the Previdia control panel it is necessary to work through the following procedure 1 Insert the programming jumper see opposite D 2 Press the Programming button on the st...

Page 9: ...to paragraph 4 2 Loop points refer to paragraph 4 1 Icon Function buttons Display Access to the configuration of the general parameters of the control panel Refer to paragraph 3 1 Access to the config...

Page 10: ...onfiguration data on the Previdia Compact control panel can be done in two ways By selecting the Factory data option from the programming menu refer to paragraph 2 2 Using the buttons available on the...

Page 11: ...tivated disables the control panel buzzer Direct alarm on second pre alarm option that if activated generates an alarm signal as soon as two detectors go into pre alarm status regardless of the zone t...

Page 12: ...Installer Property option If activated the installer reserves the management of accesses to the system by the Cloud If not activated this property is assigned to the first user enrolled 4 Press the E...

Page 13: ...e Esc and Set buttons will allow you to exit the section without changing the programming or saving it 3 5 Configuring the loops The operations for the configuration of the loops and the devices conne...

Page 14: ...n in the columns on the left A and the newly detected configuration in the columns on the right B Positions in which changes have not been detected will be outlined in green Changes will be indicated...

Page 15: ...in configuration The lower part C provides the following buttons Loop reset button to reset the loop and reassess its status In the event of a Loop open fault it will be necessary to tap on this butt...

Page 16: ...SD card and there is the file Logo bmp file is the image contained in it 260x222 pixel will be shown on the stand by screen The Esc and Set buttons will allow you to exit the section without changing...

Page 17: ...t control panels are supplied at default with the first 4 codes already pre set 3 9 Configuring the communicator To set the network parameters you must first enter the control panel programming phase...

Page 18: ...rent from that detected by the control panel the appropriate icon inside the control panel configuration screen will change status and appear in yellow 3 9 1 Configuration of the PREVIDIA C COM module...

Page 19: ...w the system can be configured so that the extinction channel is activated when there are at least two alarms in zone 2 3 10 3Extinction input The Inputs button C will allow you to configure the contr...

Page 20: ...disables the programmed inputs for manual activation of the extinction procedure Disab Man Extinc option 4 23 Manual only mode of EN 12094 1 disables the automatic activation of the extinction proced...

Reviews: