background image

1

Installation and programming manual

ODI100H

Dual PIR detector for outdoor use

Installation and programming manual

Summary of Contents for ODI100H

Page 1: ...1 Installation and programming manual ODI100H Dual PIR detector for outdoor use Installation and programming manual ...

Page 2: ... 6 2 3 Antimasking function 7 2 4 LEDs enabling 7 3 Installation 7 3 1 Placement 8 3 2 Mounting 8 4 Programming 9 5 Trouble shooting 10 6 Maintenance and periodic checks 10 7 Disposal and scrapping 10 Appendix Order codes 11 Copyright The information contained in this document is the sole property of INIM Electronics s r l No part may be copied without written authorization from INIM Electronics s...

Page 3: ...s double element with UV filter Programmable infrared sensitivity Low PIR beam precision adjustment patented system AND OR selectable function Mechanism for horizontal coverage adjustment UV rays resistant Fresnel lens UV resistant polycarbonate case Stainless steel wall fixing bracket Stainless steel pole fixing brackets available on request Antimasking function Anti tamper and anti dislodgement ...

Page 4: ... sen sors H Wall fixing bracket enclosure screw I Cover enclosure screw J External screw for U brackets fixing K Inner screw for U brackets fixing A B C D A G I E F H J K J K Table 3 Electronic part description L Terminal board for wire connec tion M Red LED 1 for general alarm N Green LED 2 for higher PIR detec tion O Green LED 3 for lower PIR detec tion P Higher infrared sensor PIR 1 Q Lower inf...

Page 5: ...ndix Order codes 2 FUNCTIONING 2 1 Detection range The maximum detection range is 18 m at 120 cm from the ground with covered area of about 85 25 C 75 relative humidity Particular conditions may increase or decrease the detection range ADJUSTMENT By using the knob table 2 E it is possible to move the PIR2 lower in order to obtain different ranges from 3m to 18m Table 4 Terminal board POWER Power s...

Page 6: ...n of two PIRs sensors The detector can work both in AND or in OR configuration for PIRs The figures below refer to AND set up of the PIRs see table 9 Sensor programming DIP switches 3 and 4 in ON position Different configurations of the PIRs activate alarm signal Table 6 Side view PIR2 position Distance A 3 m B 5 m C 8 m D 16 m E 18 m 1 2m 3m 5m 8m 16m 18m E A Table 7 Working examples A Detector B...

Page 7: ...leaving the DIP switch 5 table 3 R set to OFF 2 Once powered close the cover and run all the detection tests required 3 Open the cover and set the DIP switch 5 to ON 4 Close the cover immediately maximum within 10 seconds 5 Stay at least 1 meter from the front part of the detector for at least 4 min utes 2 4 LEDs enabling LED signalling activations can be enabled via the DIP switch 6 table 3 R OFF...

Page 8: ...of the two PIRs with the two green LEDs and the operation of the microwave with the yellow LED Run the operation test making sure to break the IR beams table 5 Top view e table 6 Side view by moving perpendicularly to them Once detection has been achieved wait for at least 7 8 seconds before trying to be detected again 3 2 Mounting 1 Unscrew the screw for the cover enclosure table 2 I 2 Remove the...

Page 9: ... ON Medium high sensitivity Low sensitivity Table 9 Sensor programming DIP 3 OFF ON DIP 4 OFF PIR 1 AND PIR 2 PIR 1 PIR 2 bypassed Alarm output active only when all sensors detect the presence It can be used in most outdoor installations Alarm output active when PIR 1 detect a presence Not recommended in particularly hostile environments ON PIR 2 PIR 1 bypassed PIR 1 OR PIR 2 Alarm output active w...

Page 10: ...dispose of them in accordance with applicable laws ATTENTION Do not dispose of the components or any other product material in the environment Seek the assistance of companies authorised to dispose of and recycle waste materials Table 11 Possible solutions Trouble Solution LEDs fail to switch on Check wiring connection Check the presence of current and if the voltage is between 9 5 and 16 V Make s...

Page 11: ...or use OTT100H Triple technology detector for outdoor use OTTBK100 Inox mounting bracket kit 2 U shaped brackets OTTCV100 Weather proof cover OTTHT100 Detector heater without hygrometer OTTHT200 Detector heater with hygrometer SmartLiving10100L Intrusion control panel manages 10 to 100 terminals 15 partitions 160W switching power supply SmartLiving1050 Intrusion control panel manages 10 to 50 term...

Page 12: ...via Fosso Antico snc fraz Centobuchi 63076 Monteprandone AP ITALY Tel 39 0735 705007 _ Fax 39 0735 704912 info inim biz _ www inim biz ISO 9001 Quality Management certified by BSI with certificate number FM530352 ...