IDS1200 INSTALLER MANUAL - NO. 700-171-02B ISSUED AUGUST 2002 VER 1.18 11
IDS1200 INSTALLER MANUAL
shown in the table below.
2
e
n
o
Z
2
8
e
n
o
Z
2
9
e
n
o
Z
4
:
s
t
i
n
U
2
:
s
n
e
T
6
l
a
t
o
T
2
6
10.3 Programming the Panel
!
For all programming procedures, the
[
!!!!!
]
(star) key functions as the enter key and the
[#]
(hash) key
functions as a clear key to clear incorrect or unintended entries, as a back space and to exit the
programming mode.
!
If an error has been made i.e. an attempt is made to enter anillegal value or an incorrect series of
keystrokes, the keypad will beep three times to indicate the error. The panel will automatically
discard the invalid entry allowing the correct entry to be made without manually clearing the incorrect
entry.
Procedure
1.
Ensure that neither partition is armed.
2.
Press the
[#]
key (this will clear any previous or accidental entries) followed by the 4 digit
[
INSTALLER
CODE
]
(the default code is 9999).
3.
If the correct code has been entered the green
READY
indicator will begin flashing.
4.
Press the
[
!!!!!
]
key.
5.
Enter the
[
LOCATION NUMBER
]
of the program location that you wish to change.
6.
Press the
[
!!!!!
]
key. The
READY
indicator will continue flashing.
7.
The zone
LED
’s will now display the content of the selected program location in binary format (ref. Table
2).
8.
If you wish to change the content of the location, enter the
[
NEW VALUE
]
followed by the
[
!!!!!
]
key. If you
do not wish to change the location value, press the
[#]
key. The
READY
indicator will continue flashing
and the
AWAY
indicator will start flashing.
9.
If the data value has been changed, the buzzer will give a long beep indicating that a valid entry has
been stored.
10. Repeat steps 5-8 until all necessary locations have been programmed.
11. To exit from the programming mode press the
[#]
key.
The
READY
indicator will stop flashing to indicate that the program mode has been exited.