18
INGEREV CITY Duo
Ingeteam
2. Connect the communications card with the Ethernet connection on the J15 and J18 connectors of the
control card. The end of line JP1 jumper on the control card in the station where the communications
card is connected must be removed.
J15
J18
A. Jumper JP1 on the control card, uninstalled
B. Communications card
C. Control card on the charging station
A
B
C
ABA2017IQM01_B - Installation and Operation Manual