7
AD-400 Networked Wireless Lock User Guide
LINK TO A PIM400
Î
Î
OnlyÎoneÎAD-400ÎcanÎbeÎlinkedÎatÎoneÎtime.ÎEnsureÎthatÎnoÎotherÎ
PIM400ÎunitsÎareÎinÎlinkÎmodeÎduringÎthisÎprocess.
1. Make sure that the batteries are installed in the AD-400. See
Batteries on page 11 for more information.
2. Make sure that the PIM400 is in link mode.
For PIM400-TD2: Hold down one of the LINK buttons. (LINK
button 1 or 2 will assign the AD-400 door number).
For PIM400-485: Use SUS to put the PIM400-485 into LINK
mode with the door number tab and assign the AD-400 door
number. See the SUS User Guide for more information.
3. Open the AD-400 door.
4. Create a request-to-exit condition by holding down the inside
lever or crash bar.
Î
Î
IfÎusingÎaÎcrashÎbar,ÎRequestÎtoÎExitÎ(RTX)ÎmustÎbeÎinstalled.Î
IfÎRTXÎisÎnotÎinstalled,ÎtemporarilyÎshortÎtheÎRTXÎinputÎonÎtheÎ
lockÎmainÎPCBÎduringÎthisÎprocedure.
5. While holding down the lever or crash bar, present a card to the prox or mag card reader. For a
keypad reader, press the “#” key.
6. Continue to hold down the lever or crash bar until the AD-400 Schlage button starts to blink
green, indicating that the link process has begun (approximately 8 seconds).
7. Release the inside lever or crash bar.
8. The Schlage button will blink green, and the beeper will beep.
Î
Î
TheÎnumberÎofÎgreenÎblinksÎandÎbeepsÎindicatesÎtheÎfrequencyÎchannelÎnumberÎonÎwhichÎtheÎ
lockÎisÎlinkedÎtoÎtheÎPIM400Î(example:Î3ÎblinksÎandÎbeepsÎ=Îchannel).
9. If the link fails, the Schlage button will blink red three (3) times and five (5) short beeps will sound.
The PIM400 will remain in link mode. Carefully repeat steps 1-8 above. If repeated LINK attempts
fail, change the frequency channel of the PIM400 and/or move the PIM400, then repeat steps 3-7.
10. Test the lock for normal operation. See TestÎLockÎOperation on page 8 for more information.
Re-linking is required anytime the AD-400 or the PIM400 is moved or replaced, Dynamic Channel
Switching is activated, deactivated, or the frequency channel is manually changed.
To re-link, repeat the procedure above. The AD-400 link to the PIM400 is retained in the event of
power loss.
Link LED and Beep Reference
Lights
Beeps
Action
1 Red,
1 Green
0
One link request was sent to find a PIM400 in link mode. This will
repeat once and then the lock will stop trying to find a PIM400.
1 Green
0
Successful RF packet transmission
1 Red
0
Unsuccessful RF packet transmission
Z Green
1
Z
1
Linking was successful
1
3 Red
5
Linking was unsuccessful
1 Z = Frequency channel number on which the lock is linked. The frequency channel number of each PIM400 in
the area should be known and recorded. Use this information to make sure the AD-400 linked to the intended
PIM400.
TIP
During linking, the Schlage
button will blink red and
green. Green blinks indicate
successful packets and red
blinks indicate unsuccessful
packets. If you get several
red blinks, the lock and
PIM400 may still link,
but you may experience
intermittent communication
in the future. You should
move the PIM400 closer
to the lock, select another
RF channel or add another
PIM400.