12
S9V2-SF-2A-EN
Model
S9V2C100D5PSBC
(a)
,
(b)
S9V2D120D5PSBC
Type
Downflow
Downflow
RATINGS
(c)
1st Stage Input BTUH
65,000
78,000
1st Stage Capacity BTUH (ICS)
63,300
75,800
2nd Stage Input BTUH
100,000
120,000
2nd Stage Capacity BTUH (ICS)
(d)
97,150
116,100
1st Stage Temp. Rise (Min. - Max.) °F
30 - 60
30-60
2nd Stage Temp. Rise (Min. - Max.) °F
35 - 65
35-65
AFUE (%)
96.0
96.0
Return Air Temp. (Min. - Max.) °F
45°F - 80°F
45°F - 80°F
BLOWER DRIVE
DIRECT
DIRECT
Diameter - Width (in.)
11 X 10
11 X 10
No. Used
1
1
Speeds (No.)
Variable
Variable
CFM vs. in. w.g.
See Fan Performance Table
See Fan Performance Table
Motor HP
1
1
R.P.M.
Variable
Variable
Volts / Ph / Hz
120 / 1 / 60
120 / 1 / 60
FLA
10.5
10.5
COMBUSTION FAN - Type
PSC
PSC
Drive - No. Speeds
Direct - 2
Direct - 2
Motor RPM
3300/2600
3300/2600
Volts/Ph/Hz
120 / 1 / 60
120 / 1 / 60
FLA
0.66
0.66
Inducer Orifice
1.05
1.19
FILTER - Furnished?
No
No
Type Recommended
High Velocity
High Velocity
Hi Vel. (No.-Size-Thk.)
1 - 20 X 25 - 1 in.
1 - 24 X 25 - 1 in.
VENT OUTLET DIAMETER - MIN. (in.)
(e)
2 Round
3 Round
INLET AIR DIAMETER -MIN. (in.)
2 Round
3 Round
HEAT EXCHANGER – Type
Fired
409 Stainless Steel
409 Stainless Steel
Unfired
29-4C Stainless Steel
29-4C Stainless Steel
Gauge (Fired)
20
20
ORIFICES - Main
Nat. Gas (Qty. - Drill Size)
5 - 45
6 - 45
Propane Gas (Qty. - Drill Size)
5 - 56
6 - 56
GAS VALVE
Redundant - Two Stage
Redundant - Two Stage
PILOT SAFETY DEVICE – Type
120 V SiNi Igniter
120 V SiNi Igniter