S9V2-SF-2A-EN
11
Model
S9V2B040D3PSBC
(a)
,
(b)
S9V2B060D3PSBC
S9V2B080D4PSBC
,
CFM vs. in. w.g.
See Fan Performance Table
See Fan Performance Table
See Fan Performance Table
Motor HP
1/2
1/2
3/4
R.P.M.
Variable
Variable
Variable
Volts / Ph / Hz
120 / 1 / 60
120 / 1 / 60
120 / 1 / 60
FLA
5.7
5.7
8
COMBUSTION FAN - Type
PSC
PSC
PSC
Drive - No. Speeds
Direct - 2
Direct - 2
Direct - 2
Motor RPM
3300/2600
3300/2600
3300/2600
Volts/Ph/Hz
120 / 1 / 60
120 / 1 / 60
120 / 1 / 60
FLA
0.66
0.66
0.66
Inducer Orifice
0.61
0.79
0.96
FILTER - Furnished?
No
No
No
Type Recommended
High Velocity
High Velocity
High Velocity
Hi Vel. (No.-Size-Thk.)
1 - 16 X 25 - 1 in.
1 - 16 X 25 - 1 in.
1 - 16 X 25 - 1 in.
VENT OUTLET DIAMETER - MIN. (in.)
(e)
2 Round
2 Round
2 Round
INLET AIR DIAMETER -MIN. (in.)
2 Round
2 Round
2 Round
HEAT EXCHANGER – Type
Fired
409 Stainless Steel
409 Stainless Steel
409 Stainless Steel
Unfired
29-4C Stainless Steel
29-4C Stainless Steel
29-4C Stainless Steel
Gauge (Fired)
20
20
20
ORIFICES - Main
Nat. Gas (Qty. - Drill Size)
2 - 45
3 - 45
4 - 45
Propane Gas (Qty. - Drill Size)
2 - 56
3 - 56
4 - 56
GAS VALVE
Redundant - Two Stage
Redundant - Two Stage
Redundant - Two Stage
PILOT SAFETY DEVICE
Type
120 V SiNi Igniter
120 V SiNi Igniter
120 V SiNi Igniter
BURNERS - TYPE - QTY
Inshot - 2
Inshot - 3
Inshot - 4
POWER CONN. - V/Ph/HZ
(f)
120 / 1 / 60
120 / 1 / 60
120 / 1 / 60
Ampacity (Amps)
7.9
7.9
10.8
Max. Overcurrent Protection (Amps)
15
15
15
PIPE CONN. SIZE (IN.)
1/2
1/2
1/2
(a)
Meets Energy Star
(b)
Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3 - latest edition.
(c)
For U.S. Applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For
Canadian applications, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.
(d)
Based on U.S. government standard tests.
(e)
Refer to Vent Length Table in the Installer's Guide.
(f)
The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.