47629519 Rev. C 

EN-9

EN

Checking High Airend Temperature Sensor

It is recommended that the discharge temperature sensor 

(2att) is checked regularly as follows:

a.  for air cooled compressors, stop the cooling blower 

by opening the blower / fan motor circuit breaker.

the compressor should trip at 109 °C (228 °f). a trip warning 

will appear on the controller display.

Cleaning Motor Cowl

1.  Ensure the compressor is electrically isolated 

for at least 15 minutes before commencing any 

maintenance work.

2.  Remove the rear door from the compressor.
3.  using a clean dry cloth, remove dust from the surface 

of the motor cowl and ensure all ventilation slots are 

free of obstructions.

4.  Replace the rear door.

Removing/ Replacing Starter Box Power Drive Module 

(PDM) Filter Element (for VSD only) 

see figure 3.

1.  Ensure compressor is electrically isolated for at least 

15 minutes before commencing any maintenance 

work.

2.  unclip the front grill of the starter box filter housing.
3.  Remove the filter element from the housing and 

replace with a new filter element.

4.  Replace the front grill.

Figure 3: Starter Box Power Drive Module (PDM) Filter Element Replacement

RELEASED 23/May/2019 07:27:22 GMT

Summary of Contents for RS11i

Page 1: ...5ie RS15ne RS18ie RS18ne RS22ie RS22ne RS11i RS15i RS15n RS18i RS18n RS22i RS22n Product Maintenance Information EN Informaci n de mantenimiento del producto ES Informations relatives l entretien du p...

Page 2: ...sor 9 Cleaning Motor Cowl 9 Removing Replacing Starter Box Power Drive Module PDM Filter Element for VSD only 9 Cleaning Checking Condensate Drain 10 Cleaning Installing Package Pre Filter 10 Checking...

Page 3: ...ing any maintenance work See the Product Safety Information manual for additional information Ingersoll Rand cannot know of or provide all the procedures by which repairs may be conducted and the haza...

Page 4: ...ect Clean Starter box power drive module filter element Clean Condenser TAS only Check Replace Inline Filter elements TAS only Check Dryer operation TAS only Every 2000 hours Inspect Starter box power...

Page 5: ...all pressure has been released 5 Add coolant 6 Replace the coolant fill plug and restart the compressor 7 Recheck the coolant level 8 Repeat the above steps until the coolant level is visible in the s...

Page 6: ...ment XE 70M Controller With the compressor running on load check the separator differential pressure using the controller It will be necessary to change the element if the differential pressure equals...

Page 7: ...lant 2 Remove the hose 3 Install the new hose and refill the compressor with coolant 4 Start the compressor check for leaks and check coolant level Refill as necessary Checking Minimum Pressure Check...

Page 8: ...es NOT support pressure washing coolers when they are installed in the compressor due to the dangers of spraying water in or around potential electrical power sources Follow the steps below for cooler...

Page 9: ...ork 2 Remove the rear door from the compressor 3 Using a clean dry cloth remove dust from the surface of the motor cowl and ensure all ventilation slots are free of obstructions 4 Replace the rear doo...

Page 10: ...lace the no loss drain valve service module The service module consists of the lower portion of the drain trap and is not serviceable Additionally it is recommended to replace the service module every...

Page 11: ...mpressor will not meet pressure required by system Compressor not sized to meet system requirements or requirements have been changed Contact your local Ingersoll Rand representative Air loss due to p...

Page 12: ...or replace Separator element is punctured or incorrect or requires changing or not sealing correctly Replace Incorrect coolant has been added Drain system check for damage Clean refill with correct c...

Page 13: ...ts High airend discharge temperature Compressor operating above rated pressure Check and modify settings Review system requirements and contact your local Ingersoll Rand representative Low coolant lev...

Page 14: ...ontroller faulty Contact your local Ingersoll Rand representative Change separator element and or high sump pressure Faulty pressure transducer measurement Calibrate and validate the wet sump and pack...

Page 15: ...mergency Stop 24Vac input not being detected on terminal R1C emergency stop button pressed Identify reason why repair fault disengage button if pressed and reset conroller E 0020 Main or Blower Motor...

Page 16: ...oolant cooler cooling air side Clean or replace Fan motor direction of rotation incorrect Wire correctly SVC Required Service Level 1 Service required Service timer has alarmed Service machine and res...

Page 17: ...rload relays open for a time period of 3 seconds Remove blockage repair or replace damaged components Rem Start Fail Remote Start Failure Remote start button is pressed after compressor is running or...

Page 18: ...red Drive faulty Contact your local Ingersoll Rand representative Controller faulty Contact your local Ingersoll Rand representative VSD FAULT Internal Fault 38 Drive faulty Contact your local Ingerso...

Page 19: ...eck ambient temp PDM filters dirty or heatsink dirty Check VSD heatsink fan operation Torque Limit Current Limit 12 Compressor operating above rated pressure Check and modify settings Review system re...

Page 20: ...ty Restore the nominal conditions Condensate drain is not functioning See Figure 5 Clean the condenser Replace the coil of the drainage solenoid valve if burned Clean or replace the drainage solenoid...

Page 21: ...gerating circuit without load Turn off the dryer and call your local Ingersoll Rand distributor The temperature control probe is positioned improperly or faulty Check the probe if the trouble persists...

Page 22: ...ation NOTICE The temperature control probe is extremely delicate Do not remove the probe from its position In case of any kind of problem please contact your local Ingersoll Rand distributor Figure 5...

Page 23: ...ce of this equipment The chart below provides a brief guide to common symptoms probable causes and remedies Table 9 Condensate Drain Troubleshooting Chart TROUBLE CAUSE ACTION Solenoid condensate valv...

Page 24: ...ingersollrandproducts com 2019 Ingersoll Rand RELEASED 23 May 2019 07 27 22 GMT...

Page 25: ...tions Compresseur vis refroidi par contact Informations relatives la maintenance du produit RS15ie RS15ne RS18ie RS18ne RS22ie RS22ne RS11i RS15i RS15n RS18i RS18n RS22i RS22n Informations relatives l...

Page 26: ...ontage du refroidisseur air 8 V rification du capteur de temp rature du bloc de compression 9 Nettoyage du capot moteur 9 Retrait remplacement de l l ment filtrant du module de motorisation PDM du bo...

Page 27: ...ce Voir le manuel d information sur la s curit d emploi du produit pour plus d informations Ingersoll Rand ne peut pas conna tre ou d crire toutes les proc dures gr ce auxquelles les r parations peuve...

Page 28: ...ur TAS uniquement V rification Remplacer l ments de filtre en ligne TAS uniquement V rification Fonctionnement du s cheur TAS uniquement Toutes les 2000 heures Inspecter l ment filtrant du module de m...

Page 29: ...roidissement pour v rifier que la pression a bien t vacu e 5 Ajoutez du liquide de refroidissement 6 Remettez en place le bouchon de remplissage du liquide de refroidissement et red marrez le compress...

Page 30: ...ement REMARQUE Le r servoir s parateur d origine est horizontal Ces chiffres sont donn s titre indicatif Changement du filtre de liquide de refroidissement 1 Arr ter la machine l isoler lectriquement...

Page 31: ...oin de ne pas endommager la cr pine ou les surfaces d tanch it 4 Nettoyez et inspectez toutes les pi ces avant le remontage 5 Lorsque l ensemble est install confirmez le sens correct d coulement Obser...

Page 32: ...plus froide jusqu ce que les refroidisseurs soient suffisamment propres Remplacezz les panneaux d acc s avant de remettre la compresseur en service b En pr sence de salet paisse de poussi re en paque...

Page 33: ...r tout travail de maintenance 2 D crocher la grille avant du logement du filtre du bo tier de d marrage 3 Enlever l l ment filtrant du logement et le remplacer par un nouvel l ment filtrant 4 Remplace...

Page 34: ...acer la courroie le v rin gaz A V rin Gaz B Support bracket part of pivoted assembly C came de tension 1 Arr ter la machine l isoler lectriquement et vacuer toute la pression pi g e 2 Installer une cl...

Page 35: ...eaux 4 et 5 L arr t d urgence a t enfonc mais pas rel ch Identifiez pourquoi corrigez la d faillance lib rez le bouton et r initialisez le contr leur L arr t d urgence a t enfonc et rel ch mais le con...

Page 36: ...a conduite et le refroidissement de l air v rifiez le sens de rotation de la soufflante Refroidisseur de sortie sale bloqu c t refroidissement d air Nettoyez ou remplacez L ensemble de compresseur fai...

Page 37: ...rifiez l arriv e d alimentation lectrique V rifiez le fusible de protection du s choir V rifiez le contact auxiliaire du contacteur de moteur principal Dysfonctionnement du syst me du condensat V rif...

Page 38: ...distance est enfonc alors que la compresseur est en fonctionnement ou le bouton de d marrage distance reste ferm V rifiez le fonctionnement des boutons ou les proc dures de fonctionnement D faillance...

Page 39: ...rifiez que le syst me de drainage du condensat fonctionne correctement et que le condensat est vacu l ment s parateur sale ou obstru Changer l l ment s parateur La machine s arr te mais aucun message...

Page 40: ...t local Ingersoll Rand Bas niveau du liquide de refroidissement Assurez vous de l absence de fuite V rifiez galement que l air de refoulement n est pas contamin par du liquide de refroidissement Mette...

Page 41: ...sement de la temp rature La limite de l arr t d pass e peut tre r initialis e uniquement lorsque la temp rature de refoulement du bloc de compression est inf rieure 107 C E 0866 Alimentation 24 V CC f...

Page 42: ...00 heures restantes avant qu un entretien soit requis Entretien requis 100 heures apr s qu un entretien soit requis Le temporisateur de l entretien pr liminaire a mis une alarme Le temporisateur de l...

Page 43: ...que r parez ou remplacez les composants endommag s Moteur principal OL Surcharge du moteur principal Cela se produira si les relais de surcharge du moteur principal sont ouverts pendant une p riode de...

Page 44: ...n cessaire D faillance de l entra nement Contactez votre repr sentant local Ingersoll Rand D faillance du module de contr le Contactez votre repr sentant local Ingersoll Rand Mauvais type de VSD Mauva...

Page 45: ...ngersoll Rand D faillance de la mise la terre 14 D faillance de la mise la terre lors du d marrage V rifiez que la mise la terre et les connexions ont t correctement effectu es D faut de courant d app...

Page 46: ...hage du message ESA et ES2 en cas de fonctionnement vide ou avec une faible charge Le s cheur peut mettre 2 minutes pour d marrer apr s que l interrupteur marche arr t a t enfonc V rifiez l tat du fle...

Page 47: ...aram tres C8 et C9 du panneau de commande lectronique si le trouble persiste remplacez les La sonde de contr le de temp rature n est pas correctement positionn e ou d faillante V rifiez la sonde si le...

Page 48: ...rigorifique vide teignez le s cheur et appelez votre distributeur local Ingersoll Rand La sonde de contr le de temp rature n est pas correctement positionn e ou d faillante V rifiez la sonde si le pro...

Page 49: ...VIS La sonde de contr le de temp rature est extr mement sensible Ne modifiez pas la position de la sonde En cas de probl me contactez votre distributeur local Ingersoll Rand Figure 5 nettoyage de l le...

Page 50: ...ur en confirmer le bon fonctionnement D pannage du tube de vidange du condensat pour les vidanges lectroniques seulement Cette section fournit des informations de base pour le d pannage La meilleure f...

Page 51: ...de gestion des d chets qualifi ou un service public de recyclage afin de garantir une mise au rebut appropri e du fluide frigorig ne Tableau 10 Mat riaux de construction du s choir int gr RECYCLAGE DE...

Page 52: ...ingersollrandproducts com 2019 Ingersoll Rand RELEASED 23 May 2019 07 27 22 GMT...

Page 53: ...nes Compresor de tornillo refrigerado por contacto Informaci n de mantenimiento del producto RS15ie RS15ne RS18ie RS18ne RS22ie RS22ne RS11i RS15i RS15n RS18i RS18n RS22i RS22n Informaci n de mantenim...

Page 54: ...tremo del compresor alto 8 Limpieza del cap del motor 8 Retirar sustituir el m dulo de conducci n de la caja de arranque PDM elemento de filtro solo para VSD 8 Limpieza control del drenaje de condensa...

Page 55: ...rabajo de mantenimiento Consulte el manual de informaci n de seguridad del producto para m s informaci n Ingersoll Rand no puede saber ni facilitar todos los procedimientos con los que realizar las re...

Page 56: ...onducci n de la caja de arranque Limpiar Condensador solo para TAS Comprobar Sustituir Elementos del filtro en l nea solo para TAS Comprobar Funcionamiento del secador solo para TAS Cada 2000 horas In...

Page 57: ...rada 5 A ada refrigerante 6 Cambie la pieza de relleno del refrigerante y reinicie el compresor 7 Vuelva a verificar el nivel de refrigerante 8 Repita los pasos arriba indicados hasta que el nivel de...

Page 58: ...refrigerante Controlar el elemento del separador Controlador Xe 70M Con el compresor funcionando con carga compruebe la presi n del diferencial del separador a trav s del controlador Habr que cambiar...

Page 59: ...y del mantenimiento aumentar en consecuencia El usuario establecer la frecuencia de dichas pruebas ya que est influida por factores como la severidad del ambiente de funcionamiento La MPCV se instala...

Page 60: ...je en la v lvula de drenaje situada en la parte inferior del enfriador de refrigerante El refrigerante saldr por la manguera de drenaje autom ticamente Tras el drenaje retire la manguera y cierre la v...

Page 61: ...e el filtro por los tacos de la parrilla para que estos se metan en el filtro 7 Instale el filtro de la parrilla 8 Instale las 4 tuercas de mariposa y las arandelas planas 9 Cierre el panel de admisi...

Page 62: ...la presilla del amortiguador y libere los extremos de bola de los tornillos esf ricos de los extremos del amortiguador de gas 4 Vuelva a colocar el amortiguador de gas y los tornillos a la vez quitan...

Page 63: ...suelte el bot n y haga reset del controlador Se ha pulsado la parada de emergencia y se ha soltado pero no se ha hecho reset al controlador Repare el fallo y haga reset en el controlador El compresor...

Page 64: ...istema Aire de refrigeraci n insuficiente Compruebe los conductos o recorrido del aire de refrigeraci n y la direcci n de rotaci n del ventilador Postrefrigerador sucio y bloqueado lado aire de refrig...

Page 65: ...rriente Comprobar el suministro el ctrico entrante Comprobar el fusible de protecci n del secador Comprobar el contacto auxiliar del contactor principal del motor Funcionamiento defectuoso del sistema...

Page 66: ...botones o los procedimientos de funcionamiento Fallo de parada remota El bot n de parada remota sigue abierto o se ha pulsado un bot n de inicio Verifique el funcionamiento de los botones o los proce...

Page 67: ...ebe el circuito de alimentaci n de control y el cableado Preglednica 5 XE 50 Splo ne napake nad PRIKAZOVALNIK Xe 50M POMEN VZROK UKREP Opozorila A 2118 High Airend Discharge Pressure Izhodni tlak je v...

Page 68: ...l izven dosega 50 C ali 250 C Namestite popravite ali zamenjajte pokvarjeni senzor E 0129 Previsoka temperatura Prese ena omejitev zaustavitve Lahko ponastavite ele ko je izhodna temperatura vija nega...

Page 69: ...ilo 100 ur do SVC Zahtevano SVC Servisni alarm Servisna raven 2 100 ur do zahtevanega servisa Zahtevan servis 100 ur po zahtevanem servisu Predhodni asovnik servisa je aktiviral alarm tevec servisa je...

Page 70: ...Preobremenitev glavnega motorja Se producir si se abre el rel de sobrecarga del motor principal o del ventilador durante 3 segundos Quite el bloqueo rep relo o cambie los componentes da ados Neuspe en...

Page 71: ...p VSD Napa en tip VSD Obrnite se na lokalnega zastopnika Ingersoll Rand Okvara zaustavitve Napaka zagonskega releja ali o i enja Compruebe el rel de funcionamiento Obrnite se na lokalnega zastopnika I...

Page 72: ...ktri arja Vija ni blok je po kodovan Obrnite se na lokalnega zastopnika Ingersoll Rand Napaka ozemljitve 14 Napaka ozemljitve pri zagonu Preverite za pravilno ozemljitev in ohlapne povezave Napaka zag...

Page 73: ...e ali z nizko obremenitvijo 2 minutna zakasnitev su ilnika za zagon po pritisku stikala vklop izklop Preveriti stanje gibljive cevi ki se uporablja za kondenzacijsko drena o in ga po potrebi zamenjati...

Page 74: ...o e te ava ni odpravljena jih zamenjajte Aktivacija notranje toplotne za ite kompresorja Po akajte eno uro in ponovno preverite e motnja s tem ni odpravljena izklju ite su ilec in pokli ite lokalnega...

Page 75: ...ll Rand NIZEK PRITISK V LINIJI V evaporatorju so ledene tvorbe Preverite sondo e te ava ni odpravljena jo zamenjajte Preverite elektronsko nadzorno plo o e te ava ni odpravljena jo zamenjajte Pokli it...

Page 76: ...premikajte z njenega polo aja V primeru kakr nihkoli te av se obrnite na lokalnega distributerja Ingersoll Rand Slika 5 i enje izpustnega elektromagnetnega ventila Jemanje integriranega su ilnika iz...

Page 77: ...t n TEST para confirmar que funciona correctamente Resoluci n de problemas Drenajes de condensado s lo drenajes electr nicos Esta secci n recoge informaci n b sica para la resoluci n de problemas La d...

Page 78: ...e P ngase en contacto siempre con una planta de eliminaci n de residuos y reciclaje para la eliminaci n adecuada de todo el refrigerante Tabla 10 Materiales de construcci n del secador integrado DESMO...

Page 79: ...RELEASED 23 May 2019 07 27 22 GMT...

Page 80: ...ingersollrandproducts com 2019 Ingersoll Rand RELEASED 23 May 2019 07 27 22 GMT...

Page 81: ...ru es Compressor de parafuso resfriado por contato Informa o sobre Manuten o do Produto RS15ie RS15ne RS18ie RS18ne RS22ie RS22ne RS11i RS15i RS15n RS18i RS18n RS22i RS22n Informa o sobre manuten o do...

Page 82: ...do Ar 8 Lavagem da Tampa do Motor 8 Retirar substituir o M dulo do Comando El ctrico da Caixa do Arrancador MCE Elemento do Filtro Apenas para VSD 8 Limpeza Verifica o da Drenagem da Condensa o 9 Lim...

Page 83: ...de manuten o Consulte o manual de Informa o de Seguran a do Produto para informa o adicional Ingersoll Rand n o tem como saber ou fornecer todos os procedimentos pelos quais as repara es podem ser co...

Page 84: ...icar Substituir Elementos de filtro em linha apenas TAS Verificar Funcionamento do secador apenas TAS A cada 2000 Hrs Inspeccionar Elemento do filtro do comando el ctrico da caixa do arrancador Substi...

Page 85: ...do refrigerante e reinicie o compressor 7 Verifique o n vel de refrigerante 8 Repita os passos acima at que o n vel de refrigerante esteja vis vel no visor com o compressor a funcionar e parado NOTA...

Page 86: ...psig Controlador XE 50M Ser necess rio mudar o elemento se o controlador emitir um aviso de Servi o necess rio Mudan a do Elemento Separador 1 Pare a m quina eletricamente isolar e ventilar toda a pre...

Page 87: ...nd recomenda que a v lvula recalibrado de acordo com a tabela de manuten o Mudan a do Filtro de Ar 1 Verifique a exist ncia de sujidade e de res duos na tampa de reten o e limpe 2 Retire a tampa de re...

Page 88: ...ores dos radiadores 7 Remova o painel superior para RS15 22ie ne ou Remova a porta dianteira e traseira e o painel superior para RS11 22i RS15 22n 8 Prenda adequadamente o refrigerador e remova os qua...

Page 89: ...om detergente suave 6 Empurre o filtro sobre as cavilhas da grelha de modo a que as cavilhas empurrem atrav s do filtro 7 Instale a grelha do filtro 8 Instale as quatro porcas de orelhas e as anilhas...

Page 90: ...das pequena por baixo da mola alivie as extremidades redondas dos pernos esf ricos nas extremidades do amortecedor a g s 4 Substitua o amortecedor a g s e os pernos ao mesmo tempo removendo e substitu...

Page 91: ...rar a avaria desengatar o bot o de rearme do controlador A paragem de emerg ncia tem sido pressionada e libertada mas o controlador n o foi reajustado Reparar a avaria e repor o controlador O compress...

Page 92: ...ou substitua O compressor produz ru do excessivo Os pain is ou as portas n o est o fechadas correctamente Corrigir a falha Fuga de ar pela tubagem interna componentes Reparar ou Substituir Rolamentos...

Page 93: ...e o da correia ou na c mara de compress o Patinagem da correia de acionamento Substitua a correia e a mola a g s Polia desalinhada Realinhe a polia Polias desgastadas Substitua polias e correia A mola...

Page 94: ...rio Falha do accionamento Contacte o seu representante local da Ingersoll Rand Falha do controlador Contacte o seu representante local da Ingersoll Rand Falha de inicializa o VSD Falha cablagem de co...

Page 95: ...Entrada de 24 V CA n o detectada no terminal R1C bot o de paragem de emerg ncia premido Identificar raz o reparar a avaria desengatar o bot o de rearme se premido do controlador E 0020 Sobrecarga do...

Page 96: ...de refrigerante lado do ar de refrigera o Limpe ou substitua Sentido de rota o da ventoinha incorrecto Ligue correctamente SVC obrigat rio N vel de servi o 1 Assist ncia necess ria O temporizador de...

Page 97: ...o motor principal se abrirem por um per odo de 3 segundos Remova a obstru o repare ou substitua os componentes danificados Rem Start Fail Avaria no Arranque Remoto O bot o de arranque remoto pressiona...

Page 98: ...ante local da Ingersoll Rand Falha paragem Avaria do rel de funcionamento ou liga es Verifique o rel de funcionamento Contacte o seu representante local da Ingersoll Rand Erro de inicializa o da trans...

Page 99: ...o massa terra no arranque Verifique as liga es massa terra e liga es soltas Falha de corrente de irrup o 33 Demasiados arranques Permita que a unidade arrefe a Temperatura do dissipador de calor 29 Te...

Page 100: ...ESA e ES2 no caso de funcionamento sem carga ou com pouca carga Um atraso de 2 minutos para que o secador inicie depois de premir o interruptor ligar desligar Verifique o estado do tubo flex vel utili...

Page 101: ...blema persistir substitua Activa o da protec o t rmica interna do compressor Aguarde uma hora e verifique novamente Se a avaria persistir pare o secador e contacte o seu distribuidor local da Ingersol...

Page 102: ...oll Rand BAIXA PRESS O NA LINHA Ice formation in the evaporator Verifique a sonda se o problema persistir substitua Verifique a placa de controlo electr nica se o problema persistir substitua Contacte...

Page 103: ...ASHRAE NOTA A sonda de controlo da temperatura extremamente delicada N o retire a sonda da sua posi o Em caso de problemas contacte o seu distribuidor local da Ingersoll Rand Figura 5 Limpeza da v lv...

Page 104: ...TEST para confirmar o funcionamento correcto Resolu o de Problemas nos Drenos de Condensa o Apenas Drenos Electr nicos Esta sec o oferece informa o b sica sobre detec o e elimina o de problemas A dete...

Page 105: ...acte sempre um servi o qualificado de gest o de res duos ou reciclagem para uma elimina o adequada de todo o refrigerante Tabela 10 Materiais de Constru o do Secador Integrado DESMONTAGEM DE RECICLAGE...

Page 106: ...RELEASED 23 May 2019 07 27 22 GMT...

Page 107: ...RELEASED 23 May 2019 07 27 22 GMT...

Page 108: ...ingersollrandproducts com 2019 Ingersoll Rand RELEASED 23 May 2019 07 27 22 GMT...

Reviews: