80448517 Rev A 

PT-9

PT

Figura 7: Não introduza qualquer objecto entre a chapa de apoio do motor e o apoio da conduta do ar .

RELEASED 16/Dec/2014 10:49:53 GMT

Summary of Contents for R4-11 kW

Page 1: ...ision A December 2014 Save These Instructions Contact Cooled Rotary Screw Air Compressor Product Maintenance Information R4 11 kW RELEASED 16 Dec 2014 10 49 53 GMT PRINT LANGUAGE ENGLISH SPANISH FRENC...

Page 2: ...sor in a safe condition before consulting technical assistance The use of other than genuine Ingersoll Rand replacement parts may result in safety hazards decreased performance and increased maintenan...

Page 3: ...element if applicable Inspect Drive belt Inspect Airend Pressure System Receiver Inspect Inspect and test pressure relief valve Replace Air filter element Replace Package pre filter element Replace S...

Page 4: ...ed that coolant must be added follow the steps below 1 Stop the compressor 2 Isolate the compressor from the external air system 3 Press the emergency stop to vent the separator tank and airend Fixed...

Page 5: ...e housing taking care to avoid any particles entering the machine When changing the separator element inspect the internal components and surfaces Any suspect parts shall be replaced before the compre...

Page 6: ...ions and airborne contamination more significant cleaning or replacement may not be necessary 1 Stop the compressor 2 Isolate the compressor from the system and vent all pressure For TAS compressors i...

Page 7: ...om drain assembly 4 Remove screen from drain assembly 5 Carefully clean screen of debris 6 Reinstall screen and reattach tubes to drain assembly Cleaning Installing Package Pre Filter 1 Ensure compres...

Page 8: ...125 PSIG 62 75 20 6 16 9 0 81 125 PSIG 67 75 18 4 16 9 0 73 145 PSIG 61 75 20 7 16 9 0 81 145 PSIG 69 75 18 0 16 9 0 71 200 PSIG 72 75 16 9 16 9 0 66 7 5 hp 110 PSIG 71 75 17 2 16 9 0 68 5 5 kW 7 5 Ba...

Page 9: ...representative Air loss due to pipe hose joint or seal failure Repair or replace Air loss due to blowdown valve stuck open Repair or replace Air loss through pressure relief valve not seating or set i...

Page 10: ...ean or replace Compressor package draws too much current Compressor operating above rated pressure Check and modify settings Review system requirements and contact your local Ingersoll Rand representa...

Page 11: ...stop button pressed Identify reason why repair fault disengage button if pressed and reset conroller E 0020 Main or Blower Motor Overload Will occur if the fan or main motor overload relays open for t...

Page 12: ...te sensor or is under the control of an external device such as an X81 is loaded and the discharge pressure 4APT is greater than the maximum offline pressure If occurs for longer than 3 seconds the co...

Page 13: ...ting a fault Refer to Table 6 VSD Comm Fail VSE Communication Failure Controller does not receive a response from the VSD when requesting information Contact your local Ingersoll Rand representative D...

Page 14: ...Undervoltage Voltage Limit Mains Failure Problem with incoming power network Check incoming power leads voltage Short Circuit There is short circuiting in the motor or motor wiring Check the motor re...

Page 15: ...res YEARLY Check condition of flexible tube used for condensate drainage and replace if necessary Check if all connecting pipes are properly tightened and fixed Check if dryer is working properly afte...

Page 16: ...ermal protection Wait one hour and check again If the fault persists stop dryer and call your local Ingersoll Rand distributor Problems with the electrical components of the compressor Check the elect...

Page 17: ...ol board Disassembly of the Integrated Dryer NOTICE The dryer shall be disassembled charged or repaired by a refrigerant specialist Refrigerant liquid and lubricating oil inside the refrigeration circ...

Page 18: ...depressurize the filter housing Filter housing is under pressure and must be depressurized 2 Turn carefully the bowl in counter clockwise direction 3 Unscrew the bowl completely from the filter head a...

Page 19: ...RELEASED 16 Dec 2014 10 49 53 GMT...

Page 20: ...ingersollrandproducts com 2014 Ingersoll Rand RELEASED 16 Dec 2014 10 49 53 GMT...

Page 21: ...80448517 Versi n A Diciembre de 2014 Conserve estas instrucciones Compresor de tornillo refrigerado por contacto Informaci n de mantenimiento del producto R4 11 kW RELEASED 16 Dec 2014 10 49 53 GMT...

Page 22: ...an originales de Ingersoll Rand puede conllevar riesgos para la seguridad una reducci n del rendimiento y un incremento de la necesidad de mantenimiento as como invalidar todas las garant as Para obte...

Page 23: ...e la caja del arrancador de ser aplicable Inspecci n Correa de transmisi n Inspecci n Airend sistema de presi n receptor Inspecci n Inspeccione y pruebe la v lvula de alivio de presi n Sustituci n Fil...

Page 24: ...lece que es necesario a adir refrigerante siga los pasos indicados a continuaci n 1 Detenga el compresor 2 A sle el compresor del sistema de aire externo 3 Pulse la parada de emergencia para purgar el...

Page 25: ...oloque el elemento antiguo en una bolsa sellada y des chela de forma segura 5 Limpie la superficie de contacto de la carcasa teniendo cuidado de evitar que entren part culas en la unidad Cuando sustit...

Page 26: ...miento fiable del sistema del compresor de aire mejorar la vida til del refrigerante del compresor e incrementar la eficiencia general de este ltimo Si esta limpieza se realiza frecuentemente seg n lo...

Page 27: ...a a colocar los paneles Extracci n sustituci n del filtro del m dulo de distribuci n de la alimentaci n PDM de la caja del arrancador solo para el modelo VSD Consulte la ilustraci n 6 1 Aseg rese de q...

Page 28: ...tigua con una nueva seg n se indica en el manual de piezas 11 Una vez que la correa est en su sitio utilice el tornillo de gato para hacer descender lentamente la placa de soporte del motor 12 Localic...

Page 29: ...80448517 Rev A ES 9 ES Ilustraci n 7 No introduzca ning n elemento entre la placa de soporte del motor y el soporte del airend RELEASED 16 Dec 2014 10 49 53 GMT...

Page 30: ...est atascada en posici n abierta Rep rela o sustit yala P rdida de aire debido a que la v lvula de alivio de presi n no est bien asentada o colocada Rep rela o sustit yala P rdida de aire debido a qu...

Page 31: ...a presi n nominal Compruebe y modifique la configuraci n Revise los requisitos del sistema o p ngase en contacto con su representante local de Ingersoll Rand El filtro separador est sucio o bloqueado...

Page 32: ...e el motivo repare el fallo desbloquee el bot n si est pulsado y restablezca el controlador E 0020 Sobrecarga del motor principal o del ventilador Se producir si se abre el rel de sobrecarga del motor...

Page 33: ...pleto Alta pres de desc Alta presi n de descarga Se produce si la unidad est utilizando un sensor remoto o se encuentra bajo el control de un dispositivo externo como un X81 est cargada y la presi n d...

Page 34: ...Compruebe el funcionamiento de los botones o los procedimientos de funcionamiento Fallo del 4APT Fallo del 2ATT Fallo del sensor Falta el sensor o este es defectuoso Instale repare o sustituya el sen...

Page 35: ...Compruebe la conexi n del motor accionamiento P rdida de la fase de l nea Voltaje de CC alto Voltaje de CC bajo Sobrevoltaje de CC Subvoltaje de CC L mite de voltaje Fallo de la red el ctrica Problema...

Page 36: ...ubo flexible utilizado para el drenaje del condensado y sustit yalo en caso necesario Compruebe si todos los tubos conectados est n apretados y fijados correctamente Compruebe si el secador funciona c...

Page 37: ...y vuelva a comprobarlo Si el fallo persiste detenga el secador y p ngase en contacto con su distribuidor local de Ingersoll Rand Problemas con los componentes el ctricos del compresor Compruebe los co...

Page 38: ...elicada No retirelasondadesuposici n Encasodequeseproduzcaalg nproblema p ngaseencontactoconsudistribuidorlocaldeIngersollRand Ilustraci n 8 Limpieza de la v lvula de solenoide de drenaje Retirada del...

Page 39: ...RELEASED 16 Dec 2014 10 49 53 GMT...

Page 40: ...ingersollrandproducts com 2014 Ingersoll Rand RELEASED 16 Dec 2014 10 49 53 GMT...

Page 41: ...80448517 R vision A D cembre 2014 Veuillez conserver ces instructions Compresseur vis refroidi par contact Informations relatives la maintenance du produit R4 11 kW RELEASED 16 Dec 2014 10 49 53 GMT...

Page 42: ...ces de rechange autres que les pi ces d origine Ingersoll Rand peut compromettre la s curit r duire les performances et n cessiter une maintenance accrue et annulera toutes les garanties Pour obtenir...

Page 43: ...r servoir Inspection Inspecter et tester une soupape de d charge Remplacement l ment de filtre air Remplacement l ment de pr filtre de centrale Remplacement l ment s parateur Remplacement l ment de f...

Page 44: ...seur du syst me d air ext rieur 3 Appuyer sur l arr t d urgence pour vacuer le r servoir de s paration et le bloc de compression Les compresseurs vitesse fixe peuvent n cessiter plus de deux minutes p...

Page 45: ...pression diff rentielle est gale z ro ou d passe 1 bar 12 psig Remplacement de l l ment s parateur 1 Arr ter la machine l isoler lectriquement et vacuer toute la pression pi g e 2 Desserrer l l ment d...

Page 46: ...D visser le capuchon de retenue et retirer l ancien l ment 3 Placer le nouvel l ment et remettre le capuchon de retenue Nettoyage du syst me combin de refroidissement par air Les temp ratures de fonc...

Page 47: ...ra sur l affichage du module de contr le Nettoyage du capot moteur 1 S assurer que le compresseur est lectriquement isol pendant au moins 15 minutes avant de commencer tout travail de maintenance 2 Re...

Page 48: ...le boulon de la prise vers le bas sur la plaque du moteur pour soulever le bloc 10 Remplacer l ancienne courroie par la nouvelle comme indiqu dans le manuel des pi ces d tach es 11 Une fois la courroi...

Page 49: ...80448517 Rev A FR 9 FR Figure 7 ne rien ins rer entre la plaque de support du moteur et le support du bloc de compression RELEASED 16 Dec 2014 10 49 53 GMT...

Page 50: ...e de canalisation ou de joint R parez ou remplacez Perte de pression d air due une vanne de purge bloqu e ouverte R parez ou remplacez Perte de pression d air due la soupape de d compression qui ne jo...

Page 51: ...u compresseur fournit trop de courant Le compresseur fonctionne au del de la pression nominale V rifiez et modifiez les r glages Revoyez les exigences du syst me et contactez votre repr sentant local...

Page 52: ...ntifiez pourquoi r parez la d faillance rel chez le bouton s il est enfonc et r initialisez le module de contr le E 0020 Surchage du moteur principal ou de la soufflante S affiche si les relais de sur...

Page 53: ...consigne usine de l ensemble de l entretien Press Refoul l v e Pression de refoulement lev e Ce message appara t si le groupe utilise un capteur distance ou est contr l par un dispositif externe comm...

Page 54: ...dures de fonctionnement D faillance du 4APT D faillance du 2ATT D faillance du capteur Le capteur est manquant ou d faillant Installez r parez ou remplacez le capteur d faillant D faut du VSD X D fau...

Page 55: ...erdue V rifiez la connexion entra nement moteur Phase lin aire perdue Tension CC lev e Tension CC faible Surcharge CC Sous charge CC Limite de tension D faut sur alimentation secteur Probl me avec le...

Page 56: ...IS PAR AN V rifiez l tat du flexible utilis pour la vidange du condensat et remplacez le si n cessaire V rifiez si tous les tuyaux de raccordement sont bien serr s et fixes V rifiez que le s cheur fon...

Page 57: ...ction thermique interne du compresseur Attendez une heure et r essayez Si le probl me persiste arr tez le s cheur et contactez votre distributeur local Ingersoll Rand Probl mes des composants lectriqu...

Page 58: ...e sortie d air comprim est correctement branch e V rifiez que la conduite des connexions n est pas obstru e en cas d obstruction r solvez le probl me V rifiez si des vannes sont ferm es V rifiez l ta...

Page 59: ...ntient de l huile lubrifiante pour compresseur frigorifique Contactez syst matiquement un centre d limination et de recyclage des d chets Tableau 9 Recyclage des parties d mont es RECYCLAGE DES L MENT...

Page 60: ...ingersollrandproducts com 2014 Ingersoll Rand RELEASED 16 Dec 2014 10 49 53 GMT...

Page 61: ...80448517 Revis o A Dezembro de 2014 Guarde estas instru es Compressor de parafuso resfriado por contato Informa o sobre Manuten o do Produto R4 11 kW RELEASED 16 Dec 2014 10 49 53 GMT...

Page 62: ...r a assist ncia t cnica A utiliza o de pe as sobressalentes que n o sejam pe as sobressalentes originais da Ingersoll Rand pode colocar a seguran a em perigo reduzir o desempenho do equipamento aument...

Page 63: ...o do arrancador PDM se aplic vel Inspeccionar Correia de transmiss o Inspeccionar Conduta de ar sistema de press o receptor Inspeccionar Inspeccionar e testar a v lvula de al vio de press o Substituir...

Page 64: ...ompressor 2 Isole o compressor do sistema de ar externo 3 Pressionar a paragem de emerg ncia para ventilador o tanque separador e a conduta de ar Os compressores de velocidade fixa podem levar mais de...

Page 65: ...amenta correcta 3 Remova o elemento do inv lucro 4 Coloque o elemento usado num saco selado e elimine em seguran a 5 Limpe a superf cie de contacto do inv lucro exercendo cuidado para evitar que quais...

Page 66: ...al se as passagens externas entre as alhetas dos n cleos do refrigerador ficarem limitadas com material estranho A limpeza regular das superf cies do refrigerador suportar o o funcionamento fi vel do...

Page 67: ...tampa do motor e assegure se de que todas as ranhuras de ventila o est o livres de obstru es 4 Coloque novamente os pain is Retirar substituir o Elemento do Comando El ctrico da Caixa do Arrancador PD...

Page 68: ...olocar a correia utilize o parafuso de chave de macaco para baixar lentamente a placa de apoio do motor 12 Localize o parafuso de tens o que o parafuso de transporte por baixo da placa de apoio do mot...

Page 69: ...80448517 Rev A PT 9 PT Figura 7 N o introduza qualquer objecto entre a chapa de apoio do motor e o apoio da conduta do ar RELEASED 16 Dec 2014 10 49 53 GMT...

Page 70: ...ituir Perda de ar devido a obstru o da v lvula da descarga Reparar ou Substituir Perda de ar atrav s da v lvula de descarga de press o devido a coloca o ou configura o incorrecta Reparar ou Substituir...

Page 71: ...ompressor operando acima da press o nominal Verificar e modificar as configura es Reveja os requisitos do sistema e contacte o seu representante local da Ingersoll Rand Filtro do elemento separador su...

Page 72: ...r a avaria desengatar o bot o de rearme se premido do controlador E 0020 Sobrecarga do motor principal ou do ventilador Ocorre se os rel s da ventoinha ou do motor principal entrarem em sobrecarga e a...

Page 73: ...nidade estar dispon vel para recarregar High VSD Amb T Temperatura Ambiente do VSD Elevada A temperatura ambiente VSD atinge 52 4 C durante tr s segundos Verificar e modificar as configura es Reveja o...

Page 74: ...representante local da Ingersoll Rand Drive Init Error Avaria na Inicializa o VSD O controlador n o consegue configurar correctamente a unidade ap s o arranque ou rein cio Contacte o seu representant...

Page 75: ...r perdida Verifique a liga o do comando motor Line Phase Loss DC Voltage High DC Voltage Low DC Overvoltage DC Undervoltage Voltage Limit Mains Failure Problema com a rede de alimenta o recebida Verif...

Page 76: ...vel utilizado para drenar a condensa o e substitua conforme necess rio Verifique se todos os tubos de liga o est o adequadamente apertados e fixos Verifique se o secador est a funcionar correctamente...

Page 77: ...e uma hora e verifique novamente Se a avaria persistir pare o secador e contacte o seu distribuidor local da Ingersoll Rand Problemas com os componentes el ctricos do compressor Verifique os component...

Page 78: ...ue se a entrada sa da do ar comprimido est correctamente ligada Verifique se os tubos de liga o est o entupidos proceda em conformidade Verifique se existem v lvulas fechadas Verifique o estado dos fi...

Page 79: ...r de refrigera o Contacte sempre um centro de elimina o de res duos e instala es de reciclagem Tabela 9 Reciclagem da desmontagem DESMONTAGEM DE RECICLAGEM Estrutura e pain is A o de poli ster resina...

Page 80: ...ingersollrandproducts com 2014 Ingersoll Rand RELEASED 16 Dec 2014 10 49 53 GMT...