Ingersoll-Rand PH30F-XXX-XXX-C Operator'S Manual Download Page 8

Page 8 of 8 

PH30F-XXX-XXX-C (en)

PN 97999-1381

TROUBLE SHOOTING

Product discharged from exhaust outlet.

Check for diaphragm rupture.
Check tightness of (14) cap screw.

Air bubbles in product discharge.

Check connections of suction plumbing.
Check “O” rings between intake manifold and fl uid caps.
Check tightness of (14) cap screw.

Motor blows air or stalls.

Check (176) check valve for damage or wear.
Check for restrictions in valve / exhaust.

y

y

y

y

y

y

y

Low output volume, erratic fl ow or no fl ow.

Check air supply.
Check for plugged outlet hose.
Check for kinked (restrictive) outlet material hose.
Check for kinked (restrictive) or collapsed inlet material 
hose.
Check for pump cavitation - suction pipe should be sized 
at least as large as the inlet thread diameter of the pump 
for proper fl ow if high viscosity fl uids are being pumped. 
Suction hose must be a non-collapsing type, capable of 
pulling a high volume.
Check all joints on the inlet manifolds and suction con-
nections. These must be air tight.
Inspect the pump for solid objects lodged in the dia-
phragm chamber or the seat area.

y

y

y

y

y

y

y

DIMENSIONAL DATA

Dimensions shown are for reference only, they are displayed in inches and millimeters (mm).

Figure 4

A

B

C

D

N

G

H

J

M

L

F

K

Q - 

Exhaust Port

R - 

Material Inlet

R - 

Material Outlet

P - 

Air Inlet

DIMENSIONS

A  -  23-1/8” (587.4 mm)
B  -  30” (762.0 mm)
C  -  12-1/32” (306.4 mm)
D  -  2-3/4” (69.9 mm)

F  -  15” (381.0 mm)
G  -  32” (812.8 mm)
H  -  10-5/32” (258.0 mm)
J  -  11-21/32" (296.1 mm)

K  -  9/16” (14.3 mm)
L  -  2-3/4" (69.9 mm)
M -  22-27/32” (580.2 mm)
N  -  16" (406.4 mm)

P  -  3/4 - 14 N.P.T.
Q  -  1-1/2 - 11-1/2 N.P.S.M.

 

 

“R” Inlet / Outlet

PH30F-ASS-SXX-C 

3 - 8 N.P.T.F. - 1

PH30F-BSS-SXX-C 

Rp 3 (3 - 11 BSP parallel)

Summary of Contents for PH30F-XXX-XXX-C

Page 1: ...0 to 280 F 51 to 138 C Hytrel 20 to 150 F 29 to 66 C Nitrile 10 to 180 F 12 to 82 C Polypropylene 35 to 175 F 2 to 79 C Santoprene 40 to 225 F 40 to 107 C PTFE 40 to 225 F 4 to 107 C Viton 40 to 350 F...

Page 2: ...y y y y y y OPERATING AND SAFETY PRECAUTIONS READ UNDERSTAND AND FOLLOWTHIS INFORMATIONTO AVOID INJURY AND PROPERTY DAMAGE Obtain Material Safety Data Sheets on all materials from the supplier for pr...

Page 3: ...o air cap item 68 only diaphragm bead groove Use ONLY 1 wrap of sealant DO NOT overlap seam Fill seam with heavy duty anearobic sealant Seam to be located between bolt positions 1 and 3 refer to Torqu...

Page 4: ...o 60 Inlet Manifold PH30F AXX XXX C 1 94216 1 SS PH30F BXX XXX C 1 94216 2 SS Item Description size Qty Part No Mtl 61 Outlet Manifold PH30F AXX XXX C 1 94704 1 SS PH30F BXX XXX C 1 94704 2 SS 68 Air...

Page 5: ...ds which contact pump case when using stainless steel fasteners k Apply 1 4 wide x 1 8 thick aproximately 46 long expandable PTFE Joint Sealant to air cap item 68 only diaphragm bead groove Use ONLY 1...

Page 6: ...ert 111 spool into 135 valve block Install 137 O ring on 136 end cap and assemble end cap to 135 valve block securing with 107 end plates and 105 screws Install 140 valve insert and 141 valve plate in...

Page 7: ...nd to threads and bolt and nut flange heads which contact pump case when us ing stainless steel fasteners Figure 3 200 138 111 139 137 136 107 236 232 233 232 176 134 133 135 105 107 166 132 243 244 1...

Page 8: ...as large as the inlet thread diameter of the pump for proper flow if high viscosity fluids are being pumped Suction hose must be a non collapsing type capable of pulling a high volume Check all joints...

Reviews: