Ingersoll-Rand PH30F-XXX-XXX-C Operator'S Manual Download Page 3

PH30F-XXX-XXX-C (en) 

Page 3 of 8

y

 Hytrel® and Viton® are registered trademarks of the DuPont Company 

y

 Loctite® and 242® are registered trademarks of Henkel Loctite Corporation 

y

y

 Santoprene® is a registered trademark of Monsanto Company, licensed to Advanced Elastomer Systems, L.P. 

y

 ARO® is a registered trademark of Ingersoll-Rand Company 

y

y

 Lubriplate® is a registered trademark of Lubriplate Division (Fiske Brothers Refi ning Company) 

y

 271™ is a trademark of Henkel Loctite Corporation 

y

MAINTENANCE

Refer to the part views and descriptions as provided on 
pages 4 through 7 for parts identifi cation and service kit in-
formation.

Certain ARO “Smart Parts” are indicated which should be 
available for fast repair and reduction of down time.
Service kits are divided to service two separate dia-
phragm pump functions: 1. AIR SECTION, 2. FLUID SEC-
TION. The Fluid Section is divided further to match typical 
part Material Options.
Provide a clean work surface to protect sensitive internal 
moving parts from contamination from dirt and foreign 
matter during service disassembly and reassembly.
Keep good records of service activity and include the 
pump in preventive maintenance program.
Before disassembling, empty captured material in the 
outlet manifold by turning the pump upside down to 
drain material from the pump.

FLUID SECTION DISASSEMBLY

Remove (61) outlet manifold and (60) inlet manifold.
Remove (22) balls, (19) “O” rings, (21) seats and (76) seat 
plugs.
Remove (15 and 15a) fl uid caps.
Remove the (14) cap screw, (6) diaphragm washer, (7) dia-
phragm, (5) backup washer and (196) cushion.

NOTE: Do not scratch or mar the surface of (1) diaphragm 
rod.

FLUID SECTION REASSEMBLY

SERVICE NOTE: ARO pn 204214-T diaphragm assembly tool is 
recommended for use when reassembling the pump.

Reassemble in reverse order. Refer to the torque require-
ments on page 5.
Clean and inspect all parts. Replace worn or damaged 
parts with new parts as required.
Lubricate (1) diaphragm rod and (144) “U” cups with Lu-
briplate® FML-2 grease (94276 grease packet is included 
in service kit).
Apply 1/4” wide x 1/8” thick (approximately 46” long) 
expandable PTFE Joint Sealant to air cap (item 68 only) 
diaphragm bead groove. Use ONLY 1 wrap of sealant. DO 
NOT overlap seam. Fill seam with heavy duty anearobic 
sealant. Seam to be located between bolt positions 1 and 
3 (refer to “Torque Sequence” diagram, page 5).
Re-check torque settings after the pump has been re-
started and run a while.

y

y

y

y

y

1.
2.

3.
4.

y

y

y

y

y

GENERAL DESCRIPTION

The ARO diaphragm pump off ers high volume delivery even 
at low air pressure and a broad range of material compatibil-
ity options are available. Refer to the model and option chart. 
ARO pumps feature stall resistant design, modular air motor 
/ fl uid sections.
Air operated double diaphragm pumps utilize a pressure dif-
ferential in the air chambers to alternately create suction and 
a positive fl uid pressure in the fl uid chambers, valve checks 
insure a positive fl ow of fl uid.
Pump cycling will begin as air pressure is applied and will 
continue to pump and keep up with the demand. It will build 
and maintain line pressure and will stop cycling once maxi-
mum line pressure is reached (dispensing device closed) and 
will resume pumping as needed.

AIR AND LUBE REQUIREMENTS

WARNING

 EXCESSIVE AIR PRESSURE. Can cause pump 

damage, personal injury or property damage.

A filter capable of filtering out particles larger than 50 
microns should be used on the air supply. There is no lu-
brication required other than the “O” ring lubricant which 
is applied during assembly or repair.
If lubricated air is present, make sure that it is compatible 
with the “O” rings and seals in the air motor section of the 
pump.

OPERATING INSTRUCTIONS

Always flush the pump with a solvent compatible with 
the material being pumped if the material being pumped 
is subject to “setting up” when not in use for a period of 
time.
Disconnect the air supply from the pump if it is to be in-
active for a few hours.
The outlet material volume is governed not only by the 
air supply, but also by the material supply available at the 
inlet. The material supply tubing should not be too small 
or restrictive. Be sure not to use hose which might col-
lapse.
When the diaphragm pump is used in a forced-feed 
(fl ooded inlet) situation, it is recommended that a “check 
valve” be installed at the air inlet.
Secure the diaphragm pump legs to a suitable surface to 
insure against damage by vibration.

y

y

y

y

y

y

y

Summary of Contents for PH30F-XXX-XXX-C

Page 1: ...0 to 280 F 51 to 138 C Hytrel 20 to 150 F 29 to 66 C Nitrile 10 to 180 F 12 to 82 C Polypropylene 35 to 175 F 2 to 79 C Santoprene 40 to 225 F 40 to 107 C PTFE 40 to 225 F 4 to 107 C Viton 40 to 350 F...

Page 2: ...y y y y y y OPERATING AND SAFETY PRECAUTIONS READ UNDERSTAND AND FOLLOWTHIS INFORMATIONTO AVOID INJURY AND PROPERTY DAMAGE Obtain Material Safety Data Sheets on all materials from the supplier for pr...

Page 3: ...o air cap item 68 only diaphragm bead groove Use ONLY 1 wrap of sealant DO NOT overlap seam Fill seam with heavy duty anearobic sealant Seam to be located between bolt positions 1 and 3 refer to Torqu...

Page 4: ...o 60 Inlet Manifold PH30F AXX XXX C 1 94216 1 SS PH30F BXX XXX C 1 94216 2 SS Item Description size Qty Part No Mtl 61 Outlet Manifold PH30F AXX XXX C 1 94704 1 SS PH30F BXX XXX C 1 94704 2 SS 68 Air...

Page 5: ...ds which contact pump case when using stainless steel fasteners k Apply 1 4 wide x 1 8 thick aproximately 46 long expandable PTFE Joint Sealant to air cap item 68 only diaphragm bead groove Use ONLY 1...

Page 6: ...ert 111 spool into 135 valve block Install 137 O ring on 136 end cap and assemble end cap to 135 valve block securing with 107 end plates and 105 screws Install 140 valve insert and 141 valve plate in...

Page 7: ...nd to threads and bolt and nut flange heads which contact pump case when us ing stainless steel fasteners Figure 3 200 138 111 139 137 136 107 236 232 233 232 176 134 133 135 105 107 166 132 243 244 1...

Page 8: ...as large as the inlet thread diameter of the pump for proper flow if high viscosity fluids are being pumped Suction hose must be a non collapsing type capable of pulling a high volume Check all joints...

Reviews: