Ingersoll-Rand PE10P-A0S Series Operator'S Manual Download Page 7

PE10P-X-X-A0S (en) 

Page 7 of 8

PARTS LIST / PE10P-X-X-A0S AIR MOTOR SECTION

U

.

134

133

121

173

k

121

132

k

176

k

Figure 3

101

181

103

201

173

k

160

166

k

TORQUE REQUIREMENTS

NOTE: DO NOT OVERTIGHTEN FASTENERS.

ALL FASTENERS ARE METRIC.

Torque (134) screws to 35  -  40 in. lbs (4.0  -  4.5 Nm).

LUBRICATION / SEALANTS

Apply Lubriplate FML-2 grease to “O” rings, “U” Cups and mating parts.

U

Apply anti-seize compound to threads at assembly.

.

,

TROUBLESHOOTING

Product discharged from exhaust outlet.

 

y

Check for diaphragm rupture.

 

y

Check tightness of (6) diaphragm washer.

Air bubbles in product discharge.

 

y

Check connections of suction plumbing.

 

y

Check “O” rings between intake manifold and inlet side 

fluid caps.

 

y

Check tightness of (6) diaphragm washer.

Motor blows air or stalls.

 

y

Check (176) check valve for damage or wear.

 

y

Check for restrictions in valve / exhaust.

Low output volume, erratic flow, or no flow.

 

y

Check air supply.

 

y

Check for plugged outlet hose.

 

y

Check for kinked (restrictive) outlet material hose.

 

y

Check for kinked (restrictive) or collapsed inlet material 

hose.

 

y

Check for pump cavitation - suction pipe should be sized 

at least as large as the inlet thread diameter of the pump 

for proper flow if high viscosity fluids are being pumped. 

Suction hose must be a non-collapsing type, capable of 

pulling a high vacuum.

 

y

Check all joints on the inlet manifolds and suction con-

nections. These must be air tight.

 

y

Inspect the pump for solid objects logged in the dia-

phragm chamber or the seat area.

Summary of Contents for PE10P-A0S Series

Page 1: ...inlet 53 0 gpm 200 6 lpm Displacement Cycle 100 psig 0 226 gal 0 86 lit Maximum Particle Size 1 8 dia 3 2 mm MaximumTemperature Limits diaphragm ball seat materials E P R EPDM 60 to 280 F 51 to 138 C...

Page 2: ...ERATING AND SAFETY PRECAUTIONS READ UNDERSTAND AND FOLLOWTHIS INFORMATIONTO AVOID INJURY AND PROPERTY DAMAGE hazardous material Safe handling practices must comply with local and national laws and saf...

Page 3: ...ture stall resistant design modular air motor fluid sections Air operated double diaphragm pumps utilize a pressure differential in the air chambers to alternately create suction and positive fluid pr...

Page 4: ...XT 637396 XXT 637396 XT 96146 T 2 T 96145 A 2 Sp 93282 4 T 93281 4 T XXV 637396 XXV 637396 XV 95989 3 2 V Y327 255 4 V Y327 220 4 V MANIFOLD FLUID CAP MATERIAL OPTIONS PE10P XXS XXX A0S PE10P AKS XXX...

Page 5: ...METRIC 6 Diaphragm washer 25 30 ft lbs 33 9 40 7 Nm lubricate face with Lubriplate grease and apply Loctite 271 to threads 26 Screws 10 12 ft lbs 13 6 16 3 Nm 29 Nuts 10 12 ft lbs 13 6 16 3 Nm 131 Scr...

Page 6: ...checks 2 Remove 121 plugs AIR MOTOR SECTION REASSEMBLY 1 Clean and lubricate parts not being replaced from service kit 2 Replace 173 O rings and assemble 121 plugs 3 Assemble 132 and 166 gaskets and...

Page 7: ...nifold and inlet side fluid caps y y Check tightness of 6 diaphragm washer Motor blows air or stalls y y Check 176 check valve for damage or wear y y Check for restrictions in valve exhaust Low output...

Page 8: ...mm R 14 11 32 364 0 mm V 17 32 13 3 mm DIMENSIONS A G L Q P PE10P AXS BXS 14 7 32 361 2 mm 14 27 32 376 5 mm 2 50 8 mm 2 3 8 59 7 mm 6 31 32 176 6 mm PE10P FXS XXX A0S 16 1 32 407 3 mm 16 1 32 407 0 m...