Ingersoll-Rand MP PUMPS CHEMFLO 4 145TC Operator'S Manual Download Page 4

Page 4 of 16 

CHEMFLO 4 (en)

STORAGE PRECAUTIONS

Do not store filled with fluid at or below freezing temp of 

process fluid.

INSTALLATION

INSTALLATION FOR CHEMFLO END SUCTION 

PUMPS:

MP CHEMFLO centrifugal pumps should be installed with a 

flooded suction as near to the liquid source as possible. A MP 

CHEMFLO is not a self-priming pump. If the liquid source is 

located below the pump a footvalve and some provision for 

priming must be used. The pump housing and suction line 

must be completely filled with liquid before operation.

Piping should include shutoff valves and pipe unions on both 

the discharge and suction to isolate the pump for mainte-

nance.

Provisions for suction and discharge pressure gages are 

recommended  for  troubleshooting.  The  suction  line  should          

be as short as possible, at least as large as the pump suction 

connection, include as few fittings as possible and those 

should have a long radius to keep friction losses at a min-

imum. If a footvalve or strainer is included the FREE AREA 

should be at least three times the area of the pump suction 

connection. The suction piping must be absolutely free of 

leaks.

Both suction and discharge piping should be supported in-

dependently of the pump. never draw or pull pipe into place, 

this may impose a strain that will result in misalignment be-

tween the pump and driver or otherwise adversely affect the 

operation of the pump. After connecting piping to the pump 

rotate the shaft several times to check for rubbing or binding.

INSTALLATION FOR CHEMFLO PUMPAKS:

If it is necessary to install the pump above the level of the 

liquid, a priming line should be connected directly to the 

suction line. A check valve must be used in conjunction with 

a priming line or the priming liquid will merely pass through 

the suction line to the liquid source. The priming of the suc-

tion line evacuates the air in the suction line and pump. This 

series of pumps will not handle air and therefore all air must 

be displaced from the suction line and pump before the 

pump can operate. Be sure that the pump housing is filled 

with liquid before starting the pump. 

THE MECHANICAL 

SEAL IN THE PUMP MUST NOT BE OPERATED DRY.

Pipe or hose of the same size (or larger) as inlet and outlet 

openings should be used on the installation.  When using 

pipe, avoid sharp bends and use long radius elbows wherev-

er possible. This will keep friction loss at a minimum and al-

low the pump to operate more effectively. Use pipe dope on 

all connections and be sure all fittings are airtight, especially 

on the suction side of the pump. An air leak on the suction 

side of the pump will prevent proper operation. A section of 

non-collapsible hose between piping and pump may be used 

as a vibration dampener.

BEARING INSTALLATION (PEDESTAL MODELS):

Check the shaft to insure that it rotates freely. Shafts should 

be aligned in accordance with the instructions of the cou-

pling manufacturer. Final alignment must be performed after 

the pump has been completely installed and the pump and 

driver are at operating temperature. Proper shaft alignment is 

the responsibility of the installer.
The MP CHEMFLO centrifugal pump should be installed with 

a flooded suction as near to the liquid source as possible.  

CHEMFLO pumps are not self-priming pumps. If the liquid 

source is located below the pump a footvalve and some

provision for priming must be used. The pump housing and 

suction line must be fully primed before operation. The me-

chanical seal in the pump must not be operated dry.

Piping should include shutoff valves on both the discharge 

and suction to isolate the pump for maintenance. Provisions 

for suction and discharge pressure gages are recommended 

for trouble shooting. The suction line should be as short as 

possible, at least as large as the pump suction connection, 

include as few fittings as possible and those should be long 

radius to keep friction losses at a minimum. If a footvalve 

or strainer is included the free area should be at least three 

times the area of the pump suction connection. The suction 

piping must be absolutely free of leaks.

Both suction and discharge piping should be supported in-

dependently of the pump. Never use excessive force to move 

the pipe into place. This may impose a strain that will result 

in misalignment between the pump and driver or otherwise 

adversely affect the operation of the pump. After connecting 

pipe to the pump rotate the shaft several times to check for 

rubbing or binding.

RELEASED 03/Sep/2021 12:38:56 GMT

Summary of Contents for MP PUMPS CHEMFLO 4 145TC

Page 1: ...s of the operator Keep for future reference OPERATOR S MANUAL CHEMFLO 4 INCLUDING OPERATION INSTALLATION AND MAINTENANCE RELEASED 8 27 21 REV A CHEMFLO 4 2 X 1 1 2 INGERSOLL RAND COMPANY INC 34800 BEN...

Page 2: ...num bronze Flow CC Up to 180 gpm 681 lpm Hydraulic Up to 220 gpm 833 lpm Pedestal Up to 180 gpm 681 lpm Head Feet CC Up to 80 ft 24 m Hydraulic Up to 205 ft 62 m Pedestal Up to 80 ft 24 m Impeller CC...

Page 3: ...eals elastomers and all wetted parts to assure compatibility before using commission of the product y Verify the chemical compatibility of the pump wetted parts and the substance being pumped flushed...

Page 4: ...NOT BE OPERATED DRY Pipe or hose of the same size or larger as inlet and outlet openings should be used on the installation When using pipe avoid sharp bends and use long radius elbows wherev er poss...

Page 5: ...en tighten the drive clamp assembly to lock the shaft sleeve onto the driver shaft After all fasteners are tight including the drive clamp assem bly remove the Assembly shim from the suction connectio...

Page 6: ...otors called impellers The action of the impeller increases the fluid s velocity and pressure and directs it towards the pump outlet WEAR AND INSPECTION POINTS Shaft Inspect threads keyways and should...

Page 7: ...Install drive clamp assembly on the shaft sleeve but do not tighten Make sure the shim is installed between the impeller and the wear plate Do not remove the shim material before the drive sleeve cla...

Page 8: ...C 1 31844 CF8M SS Impeller 3 57 56C 1 30241 CF8M SS Impeller 3 93 56C 1 30240 CF8M SS Impeller 3 25 56C 1 33751 CF8M SS Impeller 4 50 145TC 1 34209 CF8M SS Impeller 3 93 145TC 1 34407 CF8M SS Impeller...

Page 9: ...e 145TC 1 35753 316 SS 7 See SealTable for Options Page No 11 8 Capscrew 3 8 16 X 3 4 4 25663 304 SS 9 Lockwasher 5 16 X 18 4 21238 304 SS 10 Adapter 145TC 1 33794 316 SS Item Description size Qty Par...

Page 10: ...35598 316 SS 5 Impeller 4 50 1 29914 CF8M SS Impeller 4 25 1 31844 CF8M SS Impeller 3 57 1 39614 CF8M SS Impeller 3 76 1 30241 CF8M SS 6 Drive Sleeve 56C 1 29785 316 SS 7 See SealTable for Options Pag...

Page 11: ...HYD 37 DISP CIWBA 4 5 MP51272 N A MP34209 MP36494 CF4PMP SS HSHYD 22DISP CI F CTL 4 5VD MP51272 N A MP34209 MP36495 CF4PMP SS HSHYD 37DISP CI F CTL 4 5VD MP51272 N A MP34209 MP30487 CF4PMP SS PED 3 57...

Page 12: ...Page 12 of 16 CHEMFLO 4 en DIMENSIONAL DATA CF4 PUMPAK FOR 56C FOOTLESS MOTOR Figure 7 CF4 PUMPAK FOR 145TC MOTOR WITH FOOT Figure 8 RELEASED 03 Sep 2021 12 38 56 GMT...

Page 13: ...CHEMFLO 4 en Page 13 of 16 DIMENSIONAL DATA CF4 0 22 DISP MOTOR Figure 9 CF4 0 37 DISP MOTOR Figure 10 RELEASED 03 Sep 2021 12 38 56 GMT...

Page 14: ...Page 14 of 16 CHEMFLO 4 en DIMENSIONAL DATA CF4 PED Figure 11 RELEASED 03 Sep 2021 12 38 56 GMT...

Page 15: ...there are no obstructions in the suc tion line Check NPSHa to ensure that there is enough liquid for pump oper ation 6 Driver is not operating at rated speed 6 Check electric motor voltage check engin...

Page 16: ...driver with pump 7 Power frame shaft is bent 7 Repalace shaft 8 Worn suction side plate or wear rings 8 Replace defective parts as required 9 Liquid heavier than expected 9 Check specific gravity and...