Ingersoll-Rand MP PUMPS CHEMFLO 4 145TC Operator'S Manual Download Page 11

CHEMFLO 4 (en) 

Page 11 of 16

SERVICE KITS

PUMP MODEL PUMP DESCRIPTION

SEAL KIT

BEARING KIT

IMPELLER

MP34999

CF4PMP SS:1.5-3 56C 3.25 T-2100

MP51271

#N/A

MP33751

MP39478

CF4PMP SS:1.5-3 56C 3.57 T-2100

MP51271

#N/A

MP30241

MP36981

CF4PMP SS:1/2-1 56C 1750 3.93 T-2100

MP51271

#N/A

MP30240

MP33774

CF4PMP SS:1/2-1 56C 1750 4.5 T-2100

MP51271

#N/A

MP29914

MP37261

CF4PMP SS:1-1 56C 1750 4.5 T-2100

MP51271

#N/A

MP29914

MP35925

CF4PMP SS:2-1 56C 3.57 T-2100

MP51271

#N/A

MP30241

MP38524

CF4PMP SS:2-1 56C 3.93 T-2100 VD

MP51271

#N/A

MP30240

MP38041

CF4PMP SS:2-3 145TC XP 3.93 T-2100 OBS

MP51272

#N/A

MP34407

MP39963

CF4PMP SS:2-3 56C 3.57 T-2100

MP51271

#N/A

MP30241

MP31140

CF4PMP SS:3-1 56C MTO 4.5 T-2100

MP51271

#N/A

MP29914

MP39421

CF4PMP SS:3-3 184C 380V 50HZ 4.5 T-2100

MP51272

#N/A

MP34209

MP31160

CF4PMP SS:3-3 56C 230/460 3.93 T-2100

MP51271

#N/A

MP30240

MP38137

CF4PMP SS:3-3 56C MB 3.57 T-2100

MP51271

#N/A

MP30241

MP34688

CF4PMP SS:3-3 56C MB 4.25 T-2100

MP51271

#N/A

MP31844

MP39521

CF4PMP SS:3-3 56C MB 4.5 T-21 EP

MP51276

#N/A

MP29914

MP30628

CF4PMP SS:3-3 56C MB 4.5 T-2100

MP51271

#N/A

MP29914

MP38370

CF4PMP SS:3-3 56C WDM MB 4.5 T-2100

MP51271

#N/A

MP29914

MP38592

CF4PMP SS:5-3 184C 3.9 T-2100

MP51272

#N/A

MP34407

MP35352

CF4PMP SS:5-3 184C 4.5 T-2100

MP51272

#N/A

MP34209

MP36022

CF4PMP SS:HS HYD .22 DISP CI WBA 4.5

MP51272

#N/A

MP34209

MP36013

CF4PMP SS:HS HYD .37 DISP CI WBA 4.5

MP51272

#N/A

MP34209

MP36494

CF4PMP SS:HSHYD .22DISP CI F-CTL 4.5 VD

MP51272

#N/A

MP34209

MP36495

CF4PMP SS:HSHYD .37DISP CI F-CTL 4.5 VD

MP51272

#N/A

MP34209

MP30487

CF4PMP SS:PED 3.57 T-2100

MP51271

MP51281

MP30241

MP39616

CF4PMP SS:PED 3.75 T-2

MP51275

MP51281

MP39614

MP31845

CF4PMP SS:PED 4.25 T-2100

MP51271

MP51281

MP31844

MP30365

CF4PMP SS:PED 4.5 T-2100

MP51271

MP51281

MP29914

MP30530

CF4PMP SS:PED 4.5 T-9 TFE

MP51273

MP51281

MP29914

MP50643

CF4PPK SS:145TC 3.75 T-2100

MP51272

#N/A

MP50642

MP34408

CF4PPK SS:145TC 3.93 T-2100

MP51272

#N/A

MP34407

MP38601

CF4PPK SS:145TC 4.25 T-2100

MP51272

#N/A

MP38600

MP50296

CF4PPK SS:145TC 4.35 T-2100

MP51272

#N/A

MP50293

MP34219

CF4PPK SS:145TC 4.5 T-2100

MP51272

#N/A

MP34209

MP33752

CF4PPK SS:3.25 T-2100

MP51271

#N/A

MP33751

MP30424

CF4PPK SS:3.57 T-2100

MP51271

#N/A

MP30241

MP30423

CF4PPK SS:3.93 T-2100

MP51271

#N/A

MP30240

MP33190

CF4PPK SS:4.25 T-2100

MP51271

#N/A

MP31844

MP39192

CF4PPK SS:4.5 T-2 SSC

MP51274

#N/A

MP29914

MP29918

CF4PPK SS:4.5 T-2100

MP51271

#N/A

MP29914

SEAL TYPE OPTIONS

Seal PN Seal Type Shaft Dia. 

Mating Ring

Material

Primary Ring

Elastomer  Components

30061

2100

0.75” (19.05 mm) Ceramic

Carbon

Viton

316 SS 

30054

9

0.75” (19.05 mm) Ceramic

Carbon

Viton

316 SS

30358

21

0.75” (19.05 mm) Ceramic

Carbon

EPT

316 SS

34611

52

0.75” (19.05 mm) Silicon Carbide Silicon Carbide Buna

316 SS

22560

21

1” (25.4 mm)

Silicon Carbide Silicon Carbide Viton

18-8 SS

25015

21

1” (25.4 mm)

Ceramic

Carbon

Buna

18-8 SS

22273

2100

1” (25.4 mm)

Ceramic

Carbon

Viton

316 SS

RELEASED 03/Sep/2021 12:38:56 GMT

Summary of Contents for MP PUMPS CHEMFLO 4 145TC

Page 1: ...s of the operator Keep for future reference OPERATOR S MANUAL CHEMFLO 4 INCLUDING OPERATION INSTALLATION AND MAINTENANCE RELEASED 8 27 21 REV A CHEMFLO 4 2 X 1 1 2 INGERSOLL RAND COMPANY INC 34800 BEN...

Page 2: ...num bronze Flow CC Up to 180 gpm 681 lpm Hydraulic Up to 220 gpm 833 lpm Pedestal Up to 180 gpm 681 lpm Head Feet CC Up to 80 ft 24 m Hydraulic Up to 205 ft 62 m Pedestal Up to 80 ft 24 m Impeller CC...

Page 3: ...eals elastomers and all wetted parts to assure compatibility before using commission of the product y Verify the chemical compatibility of the pump wetted parts and the substance being pumped flushed...

Page 4: ...NOT BE OPERATED DRY Pipe or hose of the same size or larger as inlet and outlet openings should be used on the installation When using pipe avoid sharp bends and use long radius elbows wherev er poss...

Page 5: ...en tighten the drive clamp assembly to lock the shaft sleeve onto the driver shaft After all fasteners are tight including the drive clamp assem bly remove the Assembly shim from the suction connectio...

Page 6: ...otors called impellers The action of the impeller increases the fluid s velocity and pressure and directs it towards the pump outlet WEAR AND INSPECTION POINTS Shaft Inspect threads keyways and should...

Page 7: ...Install drive clamp assembly on the shaft sleeve but do not tighten Make sure the shim is installed between the impeller and the wear plate Do not remove the shim material before the drive sleeve cla...

Page 8: ...C 1 31844 CF8M SS Impeller 3 57 56C 1 30241 CF8M SS Impeller 3 93 56C 1 30240 CF8M SS Impeller 3 25 56C 1 33751 CF8M SS Impeller 4 50 145TC 1 34209 CF8M SS Impeller 3 93 145TC 1 34407 CF8M SS Impeller...

Page 9: ...e 145TC 1 35753 316 SS 7 See SealTable for Options Page No 11 8 Capscrew 3 8 16 X 3 4 4 25663 304 SS 9 Lockwasher 5 16 X 18 4 21238 304 SS 10 Adapter 145TC 1 33794 316 SS Item Description size Qty Par...

Page 10: ...35598 316 SS 5 Impeller 4 50 1 29914 CF8M SS Impeller 4 25 1 31844 CF8M SS Impeller 3 57 1 39614 CF8M SS Impeller 3 76 1 30241 CF8M SS 6 Drive Sleeve 56C 1 29785 316 SS 7 See SealTable for Options Pag...

Page 11: ...HYD 37 DISP CIWBA 4 5 MP51272 N A MP34209 MP36494 CF4PMP SS HSHYD 22DISP CI F CTL 4 5VD MP51272 N A MP34209 MP36495 CF4PMP SS HSHYD 37DISP CI F CTL 4 5VD MP51272 N A MP34209 MP30487 CF4PMP SS PED 3 57...

Page 12: ...Page 12 of 16 CHEMFLO 4 en DIMENSIONAL DATA CF4 PUMPAK FOR 56C FOOTLESS MOTOR Figure 7 CF4 PUMPAK FOR 145TC MOTOR WITH FOOT Figure 8 RELEASED 03 Sep 2021 12 38 56 GMT...

Page 13: ...CHEMFLO 4 en Page 13 of 16 DIMENSIONAL DATA CF4 0 22 DISP MOTOR Figure 9 CF4 0 37 DISP MOTOR Figure 10 RELEASED 03 Sep 2021 12 38 56 GMT...

Page 14: ...Page 14 of 16 CHEMFLO 4 en DIMENSIONAL DATA CF4 PED Figure 11 RELEASED 03 Sep 2021 12 38 56 GMT...

Page 15: ...there are no obstructions in the suc tion line Check NPSHa to ensure that there is enough liquid for pump oper ation 6 Driver is not operating at rated speed 6 Check electric motor voltage check engin...

Page 16: ...driver with pump 7 Power frame shaft is bent 7 Repalace shaft 8 Worn suction side plate or wear rings 8 Replace defective parts as required 9 Liquid heavier than expected 9 Check specific gravity and...