GENERAL INFORMATION
10
en
http://air.irco.com
TN, TT, IT 3+PE. 380
−
460V, 50Hz/60Hz.
KEY
XS1
Main terminals
QF1
Fan motor starter
QF1.1
Auxiliary contact
FU3
Transformer secondary fuse
FU1, 2
Transformer primary fuses
FR1
Solid state relay
FR2
Solid state relay
FR3
Solid state relay
EDV
Electric drain valve
DR
Variable speed drive
MM
Main motor
FM
Blower motor
MC
Dryer motor
ES
Emergency stop
1ATS
High air temperature switch
1RPS
Dryer refrigeration pressure switch
PTO
Thermistor, motor winding temp.
P1, P2
Pressure transducer
EDVO
Electronic drain valve option
DO
Dryer option
CA
Common alarm
WHT
White
RED
Red
DDP
Dryer discharge pressure (Dryer option)
ADP
Aftercooler discharge pressure
WIRES
POWER
−
Black
DC CONTROL
−
Blue
NEUTRAL
−
Light blue
PROTECTIVE EARTH
−
Green / Yellow
NOTES
1.
THE CORRECT TYPE AND RATING OF LINE INPUT FUSE
MUST BE FITTED ONTO THE CUSTOMER’S ISOLATOR OR
BREAKER CLOSE TO THE COMPRESSOR.
FAST ACTING CLASS
−
J, T OR SEMICONDUCTOR TYPE,
CURRENT LIMITING, INTERRUPT RATING
−
200,000 AMPS RMS
SECTION
2. SIZING OF ELECTRICAL COMPONENTS NOT SUPPLIED BY
INGERSOLL RAND IS THE RESPONSIBILITY OF THE CUSTOMER
AND SHOULD BE DONE IN ACCORDANCE WITH THE
INFORMATION ON THE COMPRESSOR DATA PLATE, N.E.C., AND
LOCAL ELECTRICAL CODES.
3. DECAL MUST CONFORM TO THE LATEST REVISION OF IR
SPECIFICATION 92
−
8.95.