22
Filter Replacement
Reference your Ingersoll Rand parts manual for your EMS-3000 Series System filter part numbers. Ensure
you have a sufficient supply of filters to operate your EMS-3000 Series System for the next six months.
In order to keep your system working at its optimal output, we recommend you change your filters every
two (2) weeks, as well as inspect the filter media once a week.
Please note, in certain environments the interval of filter media replacement could be more or less,
depending on the exposure to contaminants. A weekly visual inspection of the filter media will help you
determine the need.
This is a very important step to keep your system working at the level of
performance for which the application was designed.
The quantity and type of filter depends on the model(s) installed. See the chart below to determine the
quantity and type needed.
Figure 17. Filter Requirement Chart
Model
EMS-3100
EMS-3300
EMS-3300 Enclosure Filter
0
4
EMS-3000 Series Turbine Filter
1
1
EMS-3100 Enclosure Filter
2
0
EMS-3300 Enclosure Filter Media Replacement
1.
Turn the disconnect switch on the EMS-3000 Series Purifier to the OFF position.
2.
Remove the finger guard
3.
Pry the finger guard upwards to remove it, and set it aside.
4.
Discard the old filter
5.
Replace with new EMS-3300 enclosure filter media
6.
Snap on the finger guard with even pressure.
Figure 18. EMS-3300 Enclosure Filter