Ingersoll-Rand D127NC Operator'S Manual Download Page 17

16

Nirvana Cycling Refrigerated Dryer 75 through 150 scfm

http://air.irco.com

13.0 REPLACEMENT PARTS

D127NC

D170NC

D212NC

D255NC

110/1/60

230/1/60

220/1/50

110/1/60

230/1/60

220/1/50

110/1/60

230/1/60

220/1/50

110/1/60

230/1/60

220/1/50

1

Exchanger Assy

21341674 21341674 21341674 21341674 21341674 21341674 23141666 23141666 23141666 23141666 23141666 23141666

2

Evaporator Assy

21341641 21341641 21341641 21341641 21341641 21341641 23141658 23141658 23141658 23141658 23141658 23141658

3

Glycol Pump

38052262 23141245 23141245 23141245 23141245 23141245 23141245 23141245 23141245 23141245 23141245 23141245

5

Timed Sol. Drain

23141252 23141260 23141260 23141252 23141260 23141260 23141252 23141260 23141260 23141252 23141260 23141260

6

Compressor

23141146 23141153 23141211 23141195 23141294 23141211 23141138 23141120 23141112 23141096 23141104 23141112

7

Compressor 
Electronics Kit

23143688 23143696 23143720 23143704 23143712 23143720 23143738 23143746 23145816 23143753 23143761 23145816

8

Condenser

23141344 23141344 23141344 23141344 23141344 23141344 23141344 23141344 23141344 23141344 23141344 23141344

9

Fan Motor

23141419 23140973 23140973 23141419 23140973 23140973 23141419 23140973 23140973 23141419 23140973 23140973

10

Fan Blade

23141351 23141351 23141351 23141351 23141351 23141351 23141351 23141351 23141351 23141351 23141351 23141351

11

Fan Bracket

23141682 23141682 23141682 23141682 23141682 23141682 23141682 23141682 23141682 23141682 23141682 23141682

12

Filter Dryer

23141450 23141450 23141450 23141450 23141450 23141450 23141450 23141450 23141450 23141450 23141450 23141450

13

Gauge (Suction)

23141690 23141690 23141690 23141690 23141690 23141690 23141690 23141690 23141690 23141690 23141690 23141690

14

Switch On/Off

23141310 23141575 23141575 23141310 23141575 23141575 23141310 23141575 23141575 23141310 23141575 23141575

15

Light, (Hi Temp)

23141377 23141385 23141385 23141377 23141385 23141385 23141377 23141385 23141385 23141377 23141385 23141385

16

Tstat (High Temp)

21341369 21341369 21341369 21341369 21341369 21341369 21341369 21341369 21341369 21341369 21341369 21341369

17

Tstat (Operational)

21341369 21341369 21341369 21341369 21341369 21341369 21341369 21341369 21341369 21341369 21341369 21341369

18

Power Cord

23141013

-

-

23141013

23141013

23141013

Ambient Filter
Element (OPT/
NEMA 1 Only)

38052437 38052437  38052437  38052437  38052437  38052437  38052437  38052437  38052437  38052437  38052437  38052437 

Ambient Filter Kit 
(OPT/ NEMA 1 Only)

23132434 23132434  23132434  23132434  23132434  23132434  23132434  23132434  23132434  23132434  23132434  23132434 

NEMA-4 PARTS

9

Fan Motor

23141427 23141336 23140973 23141427 23141336 23140973 23141427 23141336 23141336 23141427 23141336 23141336

14

Switch On/Off

23141005 23141286 23141286 23141005 23141286 23141286 23141005 23141286 23141286 23141005 23141286 23141286

15

Light

38052080 23140999 23140999 38052080 23140999 23140999 38052080 23140999 23140999 38052080 23140999 23140999

-

Lens

38052106 38052106 38052106 38052106 38052106 38052106 38052106 38052106 38052106 38052106 38052106 38052106

-

Contactor

38052858 23141062 23141062 38052858 23141062 23141062 38052858 23141062 23141062 38052858 23141062 23141062

-

Strainer Ball

23141278 23141278 23141278 23141278 23141278 23141278 23141278 23141278 23141278 23141278 23141278 23141278

PARTS OVERVIEW

D127NC THROUGH D255NC

000000

Spare

. Quantities under this heading reflect the number of each item which we recommend be kept on hand for maintenance or repair. 

The appropriate quantity for your application will depend on how critical interruptions in service are to your operation.

Class

Quantity Suggested for

1

Minimum Domestic service where interruptions in service are acceptable.

2

Average

Domestic service where some interruptions in service are acceptable.

3

Maximum Export service or for domestic service where interruptions in service are unacceptable.

Summary of Contents for D127NC

Page 1: ... 2007 REV B Ensure that the operator reads and understands the decals and consults the manuals before maintenance or operation Ensure that the Operation and Maintenance manual is not removed permanently from the machine Ensure that maintenance personnel are adequately trained competent and have read the Maintenance Manuals a ...

Page 2: ...7 3 MOISTURE REMOVAL SYSTEM 7 4 REFRIGERATION SYSTEM 7 5 THERMAL CIRCULATING SYSTEM 7 6 CONTROLS CONTENTS PAGE 8 0 INSTALLATION AND INITIAL START UP 6 8 1 LOCATION AND MOUNTING 8 2 PIPING AND VALVES 8 3 FILTRATION 8 4 ELECTRICAL CONNECTION 8 5 INITIAL START UP 9 0 SCHEDULED MAINTENANCE 7 9 1 INTRODUCTION 9 2 REFRIGERANT CONDENSER 9 3 CONDENSATE DISCHARGE SYSTEM 10 0 TROUBLESHOOTING 8 10 1 INTRODUC...

Page 3: ...placements or adjustments to the Equipment or any costs of labor performed by the Purchaser or others without Company s prior written approval The effects of corrosion erosion and normal wear and tear are specifically excluded Performance warranties are limited to those specifically stated within the Company s proposal Unless responsibility for meeting such performance warranties are limited to sp...

Page 4: ...ions completely before operating unit 3 Pull main electrical disconnect switch and disconnect any separate control lines if used before attempting to work or perform maintenance on the unit 4 Do not attempt to service any part while machine is in an operational mode 5 Do not attempt to remove any parts without first relieving the entire air system of pressure 6 Do not attempt to remove any part of...

Page 5: ...nsurance Rating Affected READ TECHNICAL MANUAL Removing fuses will not disconnect power from dryer Always disconnect power from ALL sources before performing service READ TECHNICAL MANUAL Air Under Pressure Will Cause Injury Death Or Property Damage Relieve Press Before Servicing Condensate Drain Discharges Under Pressure Drain Requires Periodic Cleaning Service READ TECHNICAL MANUAL HIGH VOLTAGE ...

Page 6: ...er section until it becomes a high pressure liquid It then goes through a permanent filter dryer that ensures the refrigeration system is free of contaminants A small diameter capillary tube meters the refrigerant for introduction into the evaporator The refrigerant pressure is reduced upon entering the evaporator where as it evaporates removes heat from the thermal mass fluid 7 5 THERMAL CIRCULAT...

Page 7: ...the filter that best suits your filtration requirements In addition to air filtration condensate discharge oil water separators are also available to address stringent EPA regulations 8 4 ELECTRICAL CONNECTION Equipment is available in various electrical configurations Providing power to these units is accomplished as follows 115V 1 60 These units are supplied with a three wire 115V cord assembly ...

Page 8: ...n and cleaning may be required An optional ambient air filter kit can be easily installed outside the condenser 9 3 CONDENSATE DISCHARGE SYSTEM On a minimum of a monthly basis the operation of the drain should be checked Periodically the drain should be removed and cleaned to ensure no debris from the system is trapped inside Ingersoll Rand Nirvana Cycling dryers are equipped with a drain isolatio...

Page 9: ...heck and clean condenser ambient air filter Check ambient temperature and reduce below 113 F Compressor relay may be bad replace relay Check for loose wire connections at contactor or loss of power at control board Inoperative pump or pump may have lost prime Check pump and contact Ingersoll Rand for priming instructions Contact your local distributor for further assistance Open valves Change filt...

Page 10: ... L1 N G FAN FOR ACTUAL COMPRESSOR TYPES REFER TO DRAWING 550059 COMPRESSOR CONNECTIONS A 2 MAIN INCOMING POWER DISCONNECT AND FUSING WILL BE PROVIDED BY CUSTOMER 3 POWER CONNECTION TO BE PROVIDED BY FACTORY SUPPLIED POWER CORD 6 CUSTOMER OPTIONAL CONNECTIONS SHOWN IN SMALL DASHED LINES 1 POWER REQUIREMENT PROVIDED BY CUSTOMER TO BE 120VAC 20A MAXIMUM FULL LOAD CURRENT AT 15A 7 RECEPTICAL FOR DRAIN...

Page 11: ...HT BLK GRN GRN GROUND LUG GRN BLK WHT WHT WHT WHT WHT BLK BLK GRN CONNECTIONS FAN BLK BLK TERMINAL STRIP CUSTOMER CONNECTION CONTACTOR COMPRESSOR BLK BLK WHT BLK BLK COMPRESSOR CONNECTIONS REFER TO DRAWING 550059 FOR ACTUAL COMPRESSOR TYPES L1 L2 2 MAIN INCOMING POWER DISCONNECT AND FUSING WILL BE PROVIDED BY CUSTOMER 1 POWER REQUIREMENT PROVIDED BY CUSTOMER TO BE 120VAC NOTES WHT HIGH TEMP ALARM ...

Page 12: ...ORD CONNECTOR OR OTHER CONNECTION TO BE PROVIDED BY USER 2 MAIN INCOMING POWER DISCONNECT AND FUSING WILL BE PROVIDED BY CUSTOMER 3 CUSTOMER POWER CONNECTION MADE WITH A 4 CORD 16 AWG 6 FT LONG POWER CORD PROVIDED WITH UNIT 6 CUSTOMER OPTIONAL CONNECTIONS SHOWN IN SMALL DASHED LINES 1 POWER REQUIREMENT PROVIDED BY CUSTOMER TO BE 200 240VAC 15A MAXIMUM FULL LOAD CURRENT AT 10A NOTES 5 OPTIONAL EQUI...

Page 13: ...IONS FAN BLK BLK CUSTOMER CONNECTION TERMINAL STRIP BLK BLK BLK BLK RED GRN L1 L2 COMPRESSOR CONNECTIONS REFER TO DRAWING 550059 FOR ACTUAL COMPRESSOR TYPES NOTES 1 MAIN INCOMING POWER DISCONNECT AND FUSING WILL BE PROVIDED BY CUSTOMER 2 FUSED OR CIRCUIT BREAKER DISCONNECT SWITCH TO BE PROVIDED BY OTHERS AND MUST MEET NEC CODE ALL WIRING TO BE IN ACCORDANCE WITH NEC AND ALL APPLICABLE CODES SEE EQ...

Page 14: ...SSOR ELECTRICAL CONNECTION TO COMPRESSOR G R O U N D CSIR TYPE CONNECTIONS COMPRESSOR 1 S R COMP C 1 3 BLK S START 2 R GRN BLK WHT D255NC A16 CSR TYPE G R O U N D COMPRESSOR CONNECTIONS 230V 1PH 60HZ COMP WHT BLK OL 3 S R C RED 1 BLK GRN RED BLK RED GND BLK RUN ENCLOSURE CAPACITOR RELAY AND COMPRESSOR START 4 4 5 1 2 220V 1PH 50HZ 115V 1PH 60HZ 110V 1PH 50HZ D127NC A16 CSIR TYPE D212NC A16 CSIR TY...

Page 15: ...12NC D255NC AIR INLET CONNECTION 1 MPT D127NC D170NC 1 1 2 MPT D212NC D255NC SUCTION PRESSURE GAGE HIGH TEMPERATURE LIGHT ON OFF SWITCH WITH POWER ON LIGHT 29 38 27 38 31 44 1 75 16 00 14 25 19 35 12 550060 GENERAL ARRANGEMENT D127NC A16 THRU D255NC A16 NEMA 1 FRONT VIEW RIGHT SIDE VIEW LEFT SIDE VIEW TOP VIEW GENERAL ARRANGEMENT D127NC THRU D255NC NEMA 1 ...

Page 16: ...PT D127NC D170NC 1 1 2 MPT D212NC D255NC SUCTION PRESSURE GAGE ON OFF SWITCH WITH POWER ON LIGHT HIGH TEMPERATURE ALARM LIGHT 29 38 27 38 1 75 TYP 16 00 14 25 19 31 44 23 56 550061 GENERAL ARRANGEMENT D127NC A16 THRU D255NC A16 NEMA 4 FRONT VIEW RIGHT SIDE VIEW LEFT SIDE VIEW TOP VIEW A DETAIL A 12 0 GENERAL ARRANGEMENT GENERAL ARRANGEMENT D127NC THRU D255NC NEMA 4 ...

Page 17: ...141575 23141575 15 Light Hi Temp 23141377 23141385 23141385 23141377 23141385 23141385 23141377 23141385 23141385 23141377 23141385 23141385 16 Tstat High Temp 21341369 21341369 21341369 21341369 21341369 21341369 21341369 21341369 21341369 21341369 21341369 21341369 17 Tstat Operational 21341369 21341369 21341369 21341369 21341369 21341369 21341369 21341369 21341369 21341369 21341369 21341369 18 ...

Page 18: ...70NC A16 1 115 1 60 1 2 9 2 36 0 1 1 18 1 80 2 3 R404 1 14 0 852 20 14 2 300 136 0 D170NC A16 2 230 1 60 1 2 4 9 25 9 1 1 18 0 90 1 2 R404 2 3 0 994 10 7 5 300 136 0 D212NC A16 1 115 1 60 3 4 15 0 57 0 1 1 18 1 80 2 3 R404 2 0 0 909 20 13 2 300 136 0 D212NC A16 2 230 1 60 3 4 6 5 30 0 1 1 18 0 90 1 2 R404 2 0 0 909 15 9 5 300 136 0 D255NC A16 1 115 1 60 1 15 0 71 0 1 1 18 1 80 2 3 R404 2 3 0 994 2...

Reviews: