VILLAGER 6 ELECTRIC
Operators Manual
TPCC01BO00EN021 (Edition B)
Page 33
• The extension cord must accept a three-prong plug.
• The extension cord must be as short as possible and not exceed 12 ft (3.7 m).
• The extension cord must be a three-wire No. 12-AWG (American Wire Gauge) or No. 14-SWG
(British Standard Wire Gauge).
• Make sure that cords will not be stepped on, tripped over, or subject to damage or stress.
BATTERY CHARGING INTERLOCK
The battery charging interlock is a safety feature that prevents possible damage to the battery charger
and vehicle. The battery charging interlock will automatically engage when the AC cord is connected to
a power source. The vehicle will not operate when the AC cord is connected.
EXTENDED STORAGE CHARGE
The battery charger can stay connected to AC electrical power during off-season or extended storage.
STATUS INDICATOR LIGHTS
The status indicator lights give AC power availability, charge progress, and charger condition.
SYMBOL
Light Status
CONDITION
Amber
(Constant)
Shows approximate scale of current output
during Bulk phase.
Amber
(Flash On And Off)
Voltage output decreased because of high
internal charger temperature.
Shows algorithm numbers 1 to 6 for 11
seconds if no battery is connected.
Amber
(Constant)
80% or Bulk charge phase complete. In
Absorption phase.
Amber
(Flash On And Off)
Shows algorithm numbers 1 to 6 for 11
seconds if no battery is connected.
Green
(Constant)
Charging is complete. Charger in maintenance
Mode.
Green
(Flash On And Off)
Absorption phase complete. In finish phase.
Summary of Contents for Club Car VILLAGER 6 ELECTRIC
Page 2: ...Copyright 2021 Club Car LLC This manual effective September 1 2021...
Page 10: ...Page intentionally left blank...
Page 22: ...Page intentionally left blank...
Page 44: ...Page intentionally left blank...
Page 56: ...Page intentionally left blank...
Page 78: ...Page intentionally left blank...
Page 82: ...Page intentionally left blank...