background image

88-MACC010-1D-EN

3

Supplementary Electric Heaters

Table 1. AC Models Only

UNIT MODEL

ELECTRIC HEATER

MODEL

RATED

VOLT-

AGE

PHASE

AMPS

HEATER

CAPACITY

NO.

OF

STAGES

KW/STAGE

MCA

MAX. OVER

CURRENT

PROTEC-

TION

DEVICE

KW

BTUH

1

2

4TCA4024A1000A
4TCA4030A1000A
4TCA4036A1000A
4TCA4042A1000A
4TCA4048A1000A
4TCA4060A1000A
4TCA4060B1000A

BAYHTR1V05LUGAA 208/240

1

17/

20

3.6/

4.8

12300/

16400

1

3.6/

4.8

22/

25

25/

25

BAYHTR1V08LUGAA
BAYHTR1H08LUGAA

208/240

1

28/

32

5.76/

7.68

19700/

26200

1

5.76/

7.68

35/

40

35/

40

BAYHTR1V10LUGAA
BAYHTR1H10LUGAA

208/240

1

35/

40

7.2/

9.6

24600/

32800

1

7.2/

9.6

43/

50

45/

50

4TCA4030A1000A
4TCA4036A1000A
4TCA4042A1000A
4TCA4048A1000A
4TCA4060A1000A
4TCA4060B1000A

BAYHTR1V15BRKAA
BAYHTR1H15BRKAA

208/240

1

52/

60

10.8/

14.4

36900/

49100

2

7.2/

9.6

3.6/

4.8

65/

75

70/

80

4TCA4048A1000A
4TCA4060A1000A
4TCA4060B1000A

BAYHTR1V20BRKAA
BAYHTR1H20BRKAA

208/240

1

69/

80

14.4/

19.2

49100/

65500

2

7.2/

9.6

7.2/

9.6

87/

100

90/

100

1.

Any power supply and circuits must be wired and protected in accordance with local electrical codes.

2.

The values listed in the above table are for the electric heater only.

3.

Field wiring must be rated at least 75° C.

4.

* indicates an alpha character

ALL VALUES ARE FOR THE ELECTRIC HEATER ONLY

Table 2. HP Models Only

UNIT MODEL

ELECTRIC HEATER

MODEL

RATED

VOLT-

AGE

PHASE

AMPS

HEATER

CAPACITY

NO.

OF

STAGES

KW/STAGE

MCA

MAX. OVER

CURRENT

PROTEC-

TION

DEVICE

KW

BTUH

1

2

4WCA4024A1000A
4WCA4030A1000A
4WCA4036A1000A
4WCA4042A1000A
4WCA4048A1000A
4WCA4060A1000A

BAYHTR1V05LUGAA 208/240

1

17/

20

3.6/

4.8

12300/

16400

1

3.6/

4.8

22/

25

25/

25

BAYHTR1H08LUGAA 208/240

1

28/

32

5.76/

7.68

19700/

26200

1

5.76/

7.68

35/

40

35/

40

BAYHTR1H10LUGAA 208/240

1

35/

40

7.2/

9.6

24600/

32800

1

7.2/

9.6

43/

50

45/

50

4WCA4036A1000A
4WCA4042A1000A
4WCA4048A1000A
4WCA4060A1000A

BAYHTR1H15BRKAA 208/240

1

52/

60

10.8/

14.4

36900/

49100

2

7.2/

9.6

3.6/

4.8

65/

75

70/

80

4WCA4060A1000A

BAYHTR1H20BRKAA 208/240

1

69/

80

14.4/

19.2

49100/

65500

2

7.2/

9.6

7.2/

9.6

87/

100

90/

100

1.

Any power supply and circuits must be wired and protected in accordance with local electrical codes.

2.

The values listed in the above table are for the electric heater only.

3.

Field wiring must be rated at least 75° C.

4.

* indicates an alpha character

ALL VALUES ARE FOR THE ELECTRIC HEATER ONLY

Summary of Contents for BAYHTR1V05LUGA

Page 1: ...alled adjusted or altered equipment by an unqualified person could result in death or serious injury When working on the equipment observe all precautions in the literature and on the tags stickers and labels that are attached to the equipment January 2020 8 88 8 M MA AC CC C0 01 10 0 1 1D D E EN N Supplemental Electric Heaters BAYHTR1V05LUGA BAYHTR1V08LUGA BAYHTR1V10LUGA BAYHTR1V15BRKA BAYHTR1V20...

Page 2: ...r r u us se e p pr ro op pe er r s se er rv vi ic ce e t to oo ol ls s m ma ay y r re es su ul lt t i in n e eq qu ui ip pm me en nt t d da am ma ag ge e o or r p pe er rs so on na al l i in nj ju ur ry y R Re ec co on nn ne ec ct t a al ll l g gr ro ou un nd di in ng g d de ev vi ic ce es s A Al ll l p pa ar rt ts s o of f t th hi is s p pr ro od du uc ct t t th ha at t a ar re e c ca ap pa ab bl...

Page 3: ...codes 2 The values listed in the above table are for the electric heater only 3 Field wiring must be rated at least 75 C 4 indicates an alpha character ALL VALUES ARE FOR THE ELECTRIC HEATER ONLY Table 2 HP Models Only UNIT MODEL ELECTRIC HEATER MODEL RATED VOLT AGE PHASE AMPS HEATER CAPACITY NO OF STAGES KW STAGE MCA MAX OVER CURRENT PROTEC TION DEVICE KW BTUH 1 2 4WCA4024A1000A 4WCA4030A1000A 4W...

Page 4: ... of heater assembly into the opening and attach with four screws provided with mounting holes aligned with dimples in panel Install bracket holding terminal block to left of heater aligning four mounting holes with panel dimples 4 Route low voltage heater control polarized plug up to bottom of control box and attach to polarized plug that is factory installed in control box base 5 All low voltage ...

Page 5: ...88 MACC010 1D EN 5 SNIP TABS ON FOUR SIDES REMOVE PANEL AND TRIM INSULATION NOTE AC Models shown S Su up pp pl le em me en nt ta ar ry y E El le ec ct tr ri ic c H He ea at te er rs s ...

Page 6: ...s 2 Be sure power supply agrees with equipment and heater nameplate 3 Low voltage wiring to be 18 AWG minimum conductor 4 See heater nameplate for current rating of heater used 5 See unit and heater diagram for electrical connection details Typical Supplemental Heater Wiring 1Ph Power Field Wiring Control Wiring Polarized Plug See notes 1 2 NOTE AC Model shown ...

Page 7: ...88 MACC010 1D EN 7 N No ot te es s ...

Page 8: ...protect food and perishables and increase industrial productivity and efficiency We are a global business committed to a world of sustainable progress and enduring results ingersollrand com Ingersoll Rand has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice We are committed to using environmentally conscious prin...

Reviews: