Ingersoll-Rand ARO PX30R Series Operator'S Manual Download Page 4

Page 4 of 12 

PX30R-XXX-XXX-CXXX (en)

MAINTENANCE

Refer to the part views and descriptions as provided on pages 5 

through 8 for parts identification and service kit information.

 

y

Certain ARO “Smart Parts” are indicated which should be avail-

able for fast repair and reduction of down time.

 

y

Service kits are divided to service two separate diaphragm 

pump functions: 1. AIR SECTION, 2. FLUID SECTION. The Fluid 

Section is divided further to match typical part Material Op-

tions.

 

y

Provide a clean work surface to protect sensitive internal mov-

ing parts from contamination from dirt and foreign matter 

during service disassembly and reassembly.

 

y

Keep good records of service activity and include the pump in 

preventive maintenance program.

 

y

Before disassembling, empty captured material in the outlet 

manifold by turning the pump upside down to drain material 

from the pump.

FLUID SECTION DISASSEMBLY

1.  Remove (61) outlet manifold and (60) inlet manifold.

2.  Remove (22) balls, (19) “O” rings (if applicable) and (21) seats.

3.  Remove (15) fluid caps.

NOTE: Only PTFE diaphragm models use a primary diaphragm (7) 

and a backup diaphragm (8). Refer to the auxiliary view in the Fluid 

Section illustration.

4.  Remove the (14) screw, (6) diaphragm washer, (7) or (7 / 8) dia-

phragms, (5) backup washer and (196) cushion.

NOTE: Do not scratch or mar the surface of (1) diaphragm rod.

FLUID SECTION REASSEMBLY

SERVICE NOTE: ARO pn 204214-T diaphragm assembly tool is rec-

ommended for use when reassembling the pump.

 

y

Reassemble in reverse order. Refer to the torque requirements 

on page 6.

 

y

Clean and inspect all parts. Replace worn or damaged parts 

with new parts as required.

 

y

Lubricate (1) diaphragm rod and (144) “U” cups with Lubriplate® 

FML-2 grease (94276 grease packet is included in service kit).

 

y

Be certain the diaphragm assembly bottoms out on the (1) rod, 

back off PTFE diaphragm assembly far enough to align holes.

 

y

For models with PTFE diaphragms: Item (8) Santoprene dia-

phragm is installed with the side marked “AIR SIDE” towards the 

pump center body. Install the (7) PTFE diaphragm with the side 

marked “FLUID SIDE” towards the (15) fluid cap.

 

y

Re-check torque settings after the pump has been re-started 

and run a while.

GENERAL DESCRIPTION

The ARO diaphragm pump offers high volume delivery even at low 

air pressure and a broad range of material compatibility options are 

available. Refer to the model and option chart. ARO pumps feature 

stall resistant design, modular air motor / fluid sections.

Air operated double diaphragm pumps utilize a pressure differen-

tial in the air chambers to alternately create suction and a positive 

fluid pressure in the fluid chambers, valve checks insure a positive 

flow of fluid.

Pump cycling will begin as air pressure is applied and will continue 

to pump and keep up with the demand. It will build and maintain 

line pressure and will stop cycling once maximum line pressure is 

reached (dispensing device closed) and will resume pumping as 

needed.

AIR AND LUBE REQUIREMENTS

WARNING

 EXCESSIVE AIR PRESSURE. Can cause pump 

damage, personal injury or property damage.

 

y

A filter capable of filtering out particles larger than 50 microns 

should be used on the air supply. There is no lubrication re-

quired other than the “O” ring lubricant which is applied during 

assembly or repair.

 

y

If lubricated air is present, make sure that it is compatible with 

the “O” rings and seals in the air motor section of the pump.

OPERATING INSTRUCTIONS

 

y

Always flush the pump with a solvent compatible with the ma-

terial being pumped if the material being pumped is subject to 

“setting up” when not in use for a period of time.

 

y

Disconnect the air supply from the pump if it is to be inactive 

for a few hours.

 

y

The outlet material volume is governed not only by the air sup-

ply, but also by the material supply available at the inlet. The 

material supply tubing should not be too small or restrictive. 

Be sure not to use hose which might collapse.

 

y

When the diaphragm pump is used in a forced-feed (flooded 

inlet) situation, it is recommended that a “check valve” be in-

stalled at the air inlet.

 

y

Secure the diaphragm pump legs to a suitable surface to insure 

against damage by vibration.

y

 Hytrel® and Viton® are registered trademarks of the DuPont Company 

y

 Loctite® is a registered trademark of Henkel Loctite Corporation 

y

 Kynar® is a registered trademark of Arkema Inc. 

y

y

 Santoprene® is a registered trademark of Monsanto Company, licensed to Advanced Elastomer Systems, L.P. 

y

 ARO® is a registered trademark of Ingersoll-Rand Company 

y

y

 Lubriplate® is a registered trademark of Lubriplate Division (Fiske Brothers Refining Company) 

y

 262™, 271™ and 572™ are trademarks of Henkel Loctite Corporation 

y

y

 Hastelloy® is a registered trademark of Haynes International, Inc. 

y

Summary of Contents for ARO PX30R Series

Page 1: ...gm Material see Model Description Chart Weight PX30R XCX XXX CXXX 221 1 lbs 100 3 kgs PX30R ASX XXX CXXX BSX 228 8 lbs 103 8 kgs PD30R FSX XXX CXXX DSX 245 6 lbs 111 4 kgs Maximum Air Inlet Pressure 120 psig 8 3 bar Maximum Material Inlet Pressure 10 psig 0 69 bar Maximum Outlet Pressure 120 psig 8 3 bar Maximum Flow Rate 237 gpm 897 lpm flooded inlet 275 gpm 1041 lpm Displacement Cycle 100 psig 2...

Page 2: ... representative or the factory if you have questions concerning availability G End of Stroke ATEX IECEx NEC CEC F End of Stroke feedback E End of Stroke feedback Leak Detection R End of Stroke NEC Special Testing For Special Testing options please contact your nearest Ingersoll Rand Customer Service Representative or Distributor H End of Stroke Leak Detection ATEX IECEx NEC CEC L Leak Detection M ...

Page 3: ...ode requirements OPERATING AND SAFETY PRECAUTIONS READ UNDERSTAND AND FOLLOWTHIS INFORMATIONTO AVOID INJURY AND PROPERTY DAMAGE y y Obtain Material Safety Data Sheets on all materials from the supplier for proper handling instructions WARNING EXPLOSION HAZARD Models containing alu minum parts cannot be used with 1 1 1 trichloroethane methylene chloride or other halogenated hydrocarbon sol vents wh...

Page 4: ...at low air pressure and a broad range of material compatibility options are available Refer to the model and option chart ARO pumps feature stall resistant design modular air motor fluid sections Air operated double diaphragm pumps utilize a pressure differen tial in the air chambers to alternately create suction and a positive fluid pressure in the fluid chambers valve checks insure a positive fl...

Page 5: ...Qty Mtl Diaphragm Qty Mtl O Ring Qty Mtl XXA 637303 XXA 637303 XA 94091 A 2 Sp Y328 210 2 T XXB 637303 XXB 637303 XB 94110 A 2 Sp Y328 210 2 T XXC 637303 XXC 637303 XC 94091 C 2 H Y327 210 2 V XXG 637303 XXG 637303 XG 96016 2 2 B Y328 210 2 T XXL 637303 XXL 637303 XL 94090 L 2 L 94110 A 2 Sp Y328 210 2 T XXT 637303 XXT 637303 XT 94090 T 2 T 94110 A 2 Sp Y328 210 2 T XXV 637303 XXV 637303 XV 95345 ...

Page 6: ... lbs 88 1 94 9 Nm Apply anti seize compound to threads and bolt and nut flange heads which contact pump case when using stainless steel fasteners Apply Loctite 262 to threads at assembly Apply Loctite 572 to threads Note Lubriplate FML 2 is a white food grade petroleum grease 131 Screw 35 40 ft lbs 47 5 54 2 Nm Not used with PX30R XXX AXX CXXX CXX and GXX Apply PTFE tape to threads View for PX30R ...

Page 7: ...1 valve plate into 135 valve block NOTE Assemble 140 valve insert with dished side to ward 141 valve plate Assemble 141 valve plate with 2 iden tification dots toward 199 and 200 gaskets 5 Assemble 232 243 and 244 O rings 199 and 200 gaskets and 233 adapter plate to 135 valve block 6 Assemble 132 and 166 gaskets 176 checks and 232 O ring to 101 center body 7 Assemble 135 valve block and components...

Page 8: ...17 Muffler NOTE DO NOT OVERTIGHTEN FASTENERS LUBRICATION SEALANTS ASSEMBLY TORQUE REQUIREMENTS Apply Loctite 572 to threads Apply Lubriplate FML 2 grease to all O rings U Cups and mating parts A replacement major valve service assembly is available separately which includes the following 637374 for models PD30R XXX XXX CXXX 105 4 107 2 111 132 135 136 137 138 139 140 141 166 176 2 199 200 232 2 23...

Page 9: ... Check for diaphragm rupture y y Check tightness of 14 cap screw Air bubbles in product discharge y y Check connections of suction plumbing y y Check O rings between intake manifold and fluid caps y y Check tightness of 14 cap screw Motor blows air or stalls y y Check 176 check valve for damage or wear y y Check for restrictions in valve exhaust Low output volume erratic flow or no flow y y Check ...

Page 10: ...Page 10 of 12 PX30R XXX XXX CXXX en ...

Page 11: ...PX30R XXX XXX CXXX en Page 11 of 12 ...

Page 12: ...Page 12 of 12 PX30R XXX XXX CXXX en PN 97999 1111 ...