Ingersoll-Rand ARO PH30 C Series Operator'S Manual Download Page 2

Page 2 of 8 

PH30X-XXX-XXX-C (en)

WARNING

 EXCESSIVE AIR PRESSURE. Can cause per-

sonal injury, pump damage or property damage.

 

y

Do not exceed the maximum inlet air pressure as stat-

ed on the pump model plate.

 

y

Be sure material hoses and other components are 

able to withstand fluid pressures developed by this 

pump. Check all hoses for damage or wear. Be certain 

dispensing device is clean and in proper working con-

dition.

WARNING

 STATIC SPARK. Can cause explosion re-

sulting in severe injury or death. Ground pump and 

pumping system.

 

y

Use the pump grounding screw terminal provided. 

Use ARO® part no. 66885-1 ground kit or connect a 

suitable ground wire (12 ga. min.) to a good earth 

ground source.

 

y

Secure pump, connections and all contact points to 

avoid vibration and generation of contact or static 

spark.

 

y

Consult local building codes and electrical codes for 

specific grounding requirements.

 

y

After grounding, periodically verify continuity of elec-

trical path to ground. Test with an ohmmeter from 

each component (e.g., hoses, pump, clamps, contain-

er, spray gun, etc.) to ground to ensure continuity. 

Ohmmeter should show 0.1 ohms or less.

 

y

Submerse the outlet hose end, dispensing valve or 

device in the material being dispensed if possible. 

(Avoid free streaming of material being dispensed.)

 

y

Use hoses incorporating a static wire.

 

y

Use proper ventilation.

 

y

Keep inflammables away from heat, open flames and 

sparks.

 

y

Keep containers closed when not in use.

WARNING

 Pump exhaust may contain contaminants. 

Can cause severe injury. Pipe exhaust away from work 

area and personnel.

 

y

In the event of a diaphragm rupture, material can be 

forced out of the air exhaust muffler.

 

y

Pipe the exhaust to a safe remote location when 

pumping hazardous or inflammable materials.

 

y

Use a grounded 1” minimum ID hose between the 

pump and the muffler.

WARNING

 HAZARDOUS PRESSURE. Can result in se-

rious injury or property damage. Do not service or 

clean pump, hoses or dispensing valve while the sys-

tem is pressurized.

 

y

Disconnect air supply line and relieve pressure from 

the system by opening dispensing valve or device and 

/ or carefully and slowly loosening and removing out-

let hose or piping from pump.

WARNING

 HAZARDOUS MATERIALS. Can cause serious 

injury or property damage. Do not attempt to return 

a pump to the factory or service center that contains 

hazardous material. Safe handling practices must 

comply with local and national laws and safety code 

requirements.

OPERATING AND SAFETY PRECAUTIONS

READ, UNDERSTAND AND FOLLOW THIS INFORMATION TO AVOID INJURY AND PROPERTY DAMAGE.

 

y

Obtain Material Safety Data Sheets on all materials 

from the supplier for proper handling instructions.

WARNING

 EXPLOSION HAZARD. Models containing 

aluminum parts cannot be used with 1,1,1-trichlo-

roethane, methylene chloride or other halogenated 

hydrocarbon solvents which may react and explode.

 

y

Check pump motor section, fluid caps, manifolds and 

all wetted parts to assure compatibility before using 

with solvents of this type.

WARNING

 MISAPPLICATION HAZARD. Do not use 

models containing aluminum wetted parts with food 

products for human consumption. Plated parts can 

contain trace amounts of lead.

CAUTION

 Verify the chemical compatibility of the 

pump wetted parts and the substance being pumped, 

flushed or recirculated. Chemical compatibility may 

change with temperature and concentration of the 

chemical(s) within the substances being pumped, 

flushed or circulated. For specific fluid compatibility, 

consult the chemical manufacturer.

CAUTION

 Maximum temperatures are based on me-

chanical stress only. Certain chemicals will signifi-

cantly reduce maximum safe operating temperature. 

Consult the chemical manufacturer for chemical com-

patibility and temperature limits. Refer to PUMP DATA 

on page 1 of this manual.

CAUTION

 Be certain all operators of this equipment 

have been trained for safe working practices, under-

stand it’s limitations, and wear safety goggles / equip-

ment when required.

CAUTION

 Do not use the pump for the structural sup-

port of the piping system. Be certain the system com-

ponents are properly supported to prevent stress on 

the pump parts.

 

y

Suction and discharge connections should be flexi-

ble connections (such as hose), not rigid piped, and 

should be compatible with the substance being 

pumped.

CAUTION

 Prevent unnecessary damage to the pump. 

Do not allow pump to operate when out of material 

for long periods of time.

 

y

Disconnect air line from pump when system sits idle 

for long periods of time.

CAUTION

 Use only genuine ARO replacement parts to 

assure compatible pressure rating and longest service 

life.

NOTICE

 Replacement warning labels are available 

upon request: “Static Spark & Diaphragm Rupture” pn 

\ 94080.

WARNING

  = Hazards or unsafe practices which 

could result in severe personal injury, 

death or substantial property damage.

CAUTION

  = Hazards or unsafe practices which 

could result in minor personal injury, 

product or property damage.

NOTICE

  = Important installation, operation or 

maintenance information.

EXCESSIVE AIR PRESSURE

STATIC SPARK

HAZARDOUS MATERIALS

HAZARDOUS PRESSURE

Summary of Contents for ARO PH30 C Series

Page 1: ...5 3 lit Maximum Particle Size 3 8 dia 9 5 mm MaximumTemperature Limits diaphragm ball seal material E P R EPDM 60 to 280 F 51 to 138 C Hytrel 20 to 180 F 29 to 82 C Nitrile 10 to 180 F 12 to 82 C Poly...

Page 2: ...afety code requirements OPERATING AND SAFETY PRECAUTIONS READ UNDERSTAND AND FOLLOWTHIS INFORMATIONTO AVOID INJURY AND PROPERTY DAMAGE y y Obtain Material Safety Data Sheets on all materials from the...

Page 3: ...TFE Joint Sealant to air cap item 68 only diaphragm bead groove Use ONLY 1 wrap of sealant DO NOT overlap seam Fill seam with heavy duty anearobic sealant Seam to be located between bolt positions 1 a...

Page 4: ...30F BXX XXX C 1 94704 2 SS PH30F DXX XXX C 1 97417 SS PH30F FXX XXX C 1 96784 SS 68 Air Cap 1 96483 SS 69 Air Cap 1 94031 2 SS 70 Gasket 2 94100 B 77 Elbow 1 2 OD tube x 1 2 14 NPTF 1 2 59756 362 78 T...

Page 5: ...o threads at assembly Apply Loctite 271 to threads Apply anti seize compound to threads and bolt and nut flange heads which contact pump case when using stainless steel fasteners Apply 1 4 wide x 1 8...

Page 6: ...gs 3 Remove 136 end cap and 137 O ring releasing 111 spool MAJOR VALVE REASSEMBLY 1 Install new 138 and 139 U cups on 111 spool LIPS MUST FACE EACH OTHER 2 Insert 111 spool into 135 valve block 3 Inst...

Page 7: ...68 170 171 172 121 173 118 126 101 103 174 127 201 MAJOR VALVE PILOT VALVE PART GROUP Optional 94117 43 147 A replacement Major Valve Service Assembly is available separately which includes the follow...

Page 8: ...a non collapsing type capable of pulling a high volume y y Check all joints on the inlet manifolds and suction con nections These must be air tight y y Inspect the pump for solid objects lodged in th...