1. The first digit of the scale factor will be flashing.
2. Press the “TOTAL” button to scroll thru the numbers.
Scale Factor Screen
Figure 12
3. Press the “RESET” button to advance to the next number in the
scale factor.
4. Repeat steps 2 and 3 for all five digits in the scale factor. NOTE: All
digits can be scrolled between 0 and 9, except the first, which can
only be scrolled from 0 to 1.
5. When finished setting the scale factor, press the “RESET” button
and the scale factor and units measurement screen will be replaced
with the pulse delay screen.
Setting the Pulse Delay Factor
The pulse delay factor is used to correct for fast flow rates by closing the
valve in the meter between one and five pulses sooner than the selected
value. The meter is factory programmed with a pulse delay factor of 0.
Pulse Delay Screen
Figure 13
Advance thru the unit selection and all five scale factor digits by pressing
the “RESET” button. The above screen (see figure 13) will now be dis-
played.
1. The “PS-” will be followed by a flashing zero. The zero is the initial
setting of the pulse delay factor.
2. Scroll between settings (0 - 5) by pressing the “TOTAL” button.
3. When finished selecting the pulse delay factor, press the “RESET”
button and the display will return to the scale factor screen.
4. When finished programming these options, press the “PROGRAM-
MING” key and hold it until the screen flashes three times then goes
blank. Press the “RESET” button to return to the normal operating
screen.
TROUBLE SHOOTING
WARNING
Relieve the pressure prior to checking or repair-
ing the meter. Make sure all valves, controls and pumps are op-
erating correctly.
Battery icon is displayed.
S
Batteries are low.
a. Replace batteries.
Display is blank.
S
Meter is asleep.
a. Push “RESET” button.
S
Batteries are dead.
a. Replace batteries, push “RESET” button.
S
Program error.
a. Remove and reinsert batteries, push “RESET” button.
S
Loose battery connection.
a. Removebatteriesandcheckbatteryconnection, push“RESET”
button.
Meter does not latch for batching.
S
Meter is not in “AUTO” mode.
a. Press “AUTO” button and program batch size.
S
Meter was not reset after prior batch.
a. Press “RESET” button.
S
Low batteries.
a. Check for battery icon, replace batteries, push “RESET” button.
Slow or no fluid flow.
S
Filter is clogged.
a. Clean or replace the filter in the swivel nut.
S
Pump pressure is low.
a. Turn up the pump pressure.
S
Foreign material is jamming meter.
a. Contact your local distributor for repair.
Meter is inaccurate.
S
The scale factor is not correct for the fluid.
a. Enter program mode, check and reset program factor.
Batch overruns program value.
S
The pulse delay value is set too low.
a. Enter program mode, reset pulse delay to a higher value.