Page 3 of 8
635360-X (en)
Figure 3
NOTE: The threaded end of the meter will always have female threads,
so the metal end of the hose must have male threads. Apply thread seal-
ant to the male end. The inlet and outlet connections are both 1/2 N.P.T..
8. Thread the new nozzle onto the opposite end of the meter and screw
in tightly using an open ended, adjustable wrench (see figure 4).
Figure 4
9. Open all dispense position shut-off valves and start the pump to
pressurize the system.
10. To ensure accuracy, purge all air from the fluid lines and dispense
valve before use.
METER OPERATION
Manual Mode
1. Program the meter to “manual” mode by selecting “RESET”.
Manual Mode
Figure 5
2. Pull the trigger to begin the flow.
3. When the desired amount has been pumped, release the trigger to
stop the flow. Press “RESET” to reset the counter display to zero.
Programming the Preset Batch Function
1. To enter the “auto” mode, press the “AUTO” button. The following
screen will appear:
Auto Mode
Figure 6
2. The meter is now ready to be programmed. Change the batch size
by pressing the “10”, “1” and “0.1” buttons.
a. Pressing the “10” button will increase the batching amount in in-
crements of 10 units.
b. Pressing the “1” button will increase the batching amount in in-
crements of 1 unit.
c. Pressing the “0.1” button will increase the batching amount in
increments of 0.1 units.
Figure 7
3. Pull the trigger to begin the flow. The valve will automatically lock in
place, even though the trigger will fall back to the closed position.
The flow will automatically shut off when the desired batch size has
been dispensed.
NOTE: The meter willautomaticallyshut off if the trigger ispulled and the
meter does not sense any flow. The display will then begin to flash, indi-
cating the meter has shut off. Press the “RESET” button to stop the dis-
play from flashing.
Also, in case of an emergency or to interrupt a batch, the meter is
equipped with a mechanical override (see “Mechanical Override”).
CAUTION
The valve will always lock in the maximum open
position.
4. The user has the option to top off at the end of the batch. To top off
the tank, simply pull the trigger to begin the flow and release when
the desired amount has been pumped.
5. Press the “RESET” button when finished to reset the meter. It is now
ready for the next batch.
CAUTION
Do not press the “RESET” button before topping
off. The meter will begin a new batch.
NORMAL OPERATING MODE FUNCTIONS
Total
This option allows users to see the accumulated total as well as the re-
settable total.
Press and hold the “TOTAL” button while in the normal operating mode
to see the accumulated total. Continue holding, and after 3 seconds, the
screen will change to the resettable total, which displays the total fluid
dispensed since the resettable total was last set back to zero.
Press the “RESET” button while viewing the resettable total to set the
resettable total back to zero. Release the “TOTAL” button to return to the
normal operating screen.
NOTE: The accumulated total cannot be reset unless the user changes
from English units to metric units or from metric units to English units
(see “Changing Factory Settings”).
Total Function
Figure 8
Mechanical Override
In case of an emergency or to interrupt a batch, the meter is equipped
with a mechanical override. This option automatically closes the valve in
the meter, stopping the flow immediately. The display will begin to flash
because the meter does not sense any flow. Batching can be continued
after an override, even if the meter is in the middle of a programmed
batch and the display continues to flash.
Press the red “Shut-Off” button to activate the mechanical override. This
button may require considerable force to activate and can only be used
when the valve is open. Press the “RESET” button to cue up the next