94
88-A951X001-1D-EN
1.
Slide PVC through vent outlet adaptor and insert into inducer
outlet.
2.
Twist to insure PVC is fully inserted.
3.
Tighten the two clamps.
4.
Install the combustion air inlet PVC pipe.
Note:
The vent outlet adapter is used for strain relief against the
weight of the venting. The clamp should be tightened after the
internal connection is made.
Note:
If required, transition to larger venting within 2' of the cabinet.
An 2" x 3" offset coupling is required if the transition is made in
a horizontal plane. Use coupling CPL00938 (Canadian
applications may use BAYREDUCE to meet ULC-S636
requirements.) See Horizontal Venting section for proper
orientation of 2” x 3” offset coupling.
1.
Remove port cap at bottom of inducer and connect inducer
condensate tubing. Connect other end of inducer condensate
tubing to top port on the condensate trap. Cut tubing to length, if
necessary.
2.
Install previously removed port cap onto bottom port of the
inducer.
3.
Connect condensate pressure switch tubing to pressure port on
the condensate trap.
Important:
Trim the condensate pressure switch tubing to
length to ensure there is no sag or trap created.
4.
Remove port plug from rain gutter and install in new position on
opposite side of the rain gutter.
5.
Connect rain gutter condensate hose to the rain gutter and the
lower port of the condensate trap. Cut to length, as required.
5
1
3
F
Fu
urrn
na
acce
e C
Co
om
mb
bu
ussttiio
on
n A
Aiirr E
Ex
xh
ha
au
usstt O
Op
pttiio
on