Ingersoll-Rand 6662AX-X-C Operator'S Manual Download Page 7

6662AX-X-C 

Page 7 of 8

TORQUE REQUIREMENTS

  

 

NOTE: DO NOT OVERTIGHTEN FASTENERS

LUBRICATION / SEALANTS

IMPORTANT

BE CERTAIN TO ORIENT (115) SPACER LEGS

AWAY FROM BLOCKING INTERNAL PORTS

WHEN REASSEMBLING AIR SECTION.

MAJOR VALVE CROSS SECTION DETAIL

109 110 

112

114 

113 

115

111

116

Figure 3 

 

MAJOR VALVE

PILOT VALVE

118 

111

112

 113

 114

115

116

117

119 

102 

104

123 121

122 

120

108

109

110 

106

 105

See cross section detail Figure 3.

201

 128

107

127

126

195 

 195

101

231

104

102 

103 

107

106

105 

 123

121

(105) 40   50 in. lbs (4.5   5.6 Nm),

 apply Loctite Nickel Antiseize to threads.

Apply Key-Lube to all “O" rings, ”U" Cups & mating parts.

Apply Loctite 271 to threads.

Apply pipe sealant to threads.
Apply Dri-Loc 204 to threads.

1.

PARTS LIST / 6662AX-X-C AIR MOTOR SECTION

Summary of Contents for 6662AX-X-C

Page 1: ...mTemperature Limits diaphragm ball seal material Polypropylene 350 to 1750 F 1 70 to 790 C P V D F 100 to 2000 F 120 to 930 C Dimensional Data see page 8 Noise Level 70 p s i 60 c p m 77 7 db A The pump sound pressure levels published here have been updated to an Equivalent Continuous Sound Level LAeq to meet the intent of ANSI S1 13 1971 CAGI PNEU ROP S5 1 using four microphone locations NOTICE A...

Page 2: ...eturn a pump to the factory or service center that contains hazardous material y y y y y y y y y y y y y y y y Safe handling practices must comply with local and national laws and safety code requirements Obtain Material Safety Data Sheets on all materials from the supplier for proper handling instructions WARNING EXPLOSION HAZARD Models containing aluminum wetted parts cannot be used with 1 1 1 t...

Page 3: ...NANCE Refer to the part views and descriptions as provided on page 4 through 7 for parts identification and Service Kit information Certain ARO Smart Parts are indicated which should be available for fast repair and reduction of down time Service kits are divided to service two separate dia phragm pump functions 1 AIR SECTION 2 FLUID SEC TION The FLUID SECTION is divided further to match typical p...

Page 4: ... X5 92755 5 2 E Y328 16 2 T Y328 208 2 T 95912 4 E 92761 8 E XX9 637165 X9 94615 9 2 H Y328 16 2 T Y328 208 2 T Y327 342 4 V Y327 230 8 V XXB 637165 XB 94615 A 2 SP Y328 16 2 T Y328 208 2 T 95912 4 E 92761 8 E MANIFOLD FLUID CAP MATERIAL OPTIONS 6662XX XXX C Polypropylene P V D F 6662X3 6662X4 Item Description size Qty Part No Mtl Part No Mtl 6 Diaphragm Nut 2 93243 1 P 93243 2 K 15 Fluid Cap 2 94...

Page 5: ... 1 94 9 Nm apply Loctite 271 to threads 25 26 27 and 124 Fluid Caps Manifold bolts 120 140 in lbs 13 6 15 8 Nm apply Loctite Nickel Antiseize to threads 38 Bolts 40 45 in lbs 4 5 5 1 Nm COLOR CODE DIAPHRAGM BALL MATERIAL COLOR COLOR E P R Blue Blue HYTREL Cream N A NEOPRENE Green Green NITRILE Black Red POLYURETHANE N A Red SANTOPRENE Cream Cream SANTOPRENE Green N A Backup PTFE White White VITON ...

Page 6: ... Inspect and replace old parts with new parts as neces sary Look for deep scratches on metallic surfaces and nicks or cuts in O rings Take precautions to prevent cutting O rings upon instal lation Lubricate O rings with Key Lube grease Do not overtighten fasteners refer to torque specification block on view Re torque fasteners following restart y y y y y y PILOT VALVE DISASSEMBLY Remove 104 retain...

Page 7: ...116 Figure 3 MAJOR VALVE PILOT VALVE 118 111 112 113 114 115 116 117 119 102 104 123 121 122 120 108 109 110 106 105 See cross section detail Figure 3 201 128 107 127 126 195 195 101 231 104 102 103 107 106 105 123 121 105 40 50 in lbs 4 5 5 6 Nm apply Loctite Nickel Antiseize to threads Apply Key Lube to all O rings U Cups mating parts Apply Loctite 271 to threads Apply pipe sealant to threads Ap...

Page 8: ... sized at least as large as the inlet thread diameter of the pump for proper flow if high viscosity fluids are being pumped Suction hose must be a non collapsing type capable of pulling a high vacuum Check all joints on the inlet manifolds and suction con nections These must be air tight Inspect the pump for solid objects lodged in the dia phragm chamber or the seat area y y y y y y y DIMENSIONAL ...

Reviews: