3
PLACING TOOL IN SERVICE
LUBRICATION
Ingersoll–Rand No. 50
Ingersoll–Rand No. 100
Always use an air line lubricator with these tools.
We recommend the following Filter–Lubricator–Regulator
Unit:
For International – No. FRL30–C6–A29
For Model 2934P2–EU
Before starting the tool and after each eight hours of
operation, unless the air line lubricator is used, unscrew the
Oil Chamber Plug and fill the chamber with Ingersoll–Rand
No. 50 Oil.
After each forty–eight hours of operation, or as experience
indicates, inject about 3 cc of Ingersoll–Rand No. 100 Grease
(approximately 14 strokes from the No. R000A2–228 Grease
Gun) into the Grease Fitting.
For Model 2940P2–EU
Before starting the tool and after each two or three hours
of operation, unless the air line lubricator is used, detach the
air hose an inject about 3 cc of Ingersoll–Rand No. 50 Oil into
the air inlet.
After each twenty hours of operation, or as experience
indicates, inject about 6 cc of Ingersoll–Rand No. 100 Grease
(approximately 14 strokes from the No. R000A2–228 Grease
Gun) into the Grease Fitting.
MAIN LINES 3 TIMES
AIR TOOL INLET SIZE
TO
AIR
SYSTEM
TO
AIR
TOOL
LUBRICATOR
REGULATOR
FILTER
BRANCH LINE 2 TIMES
AIR TOOL INLET SIZE
DRAIN REGULARLY
COMPRESSOR
(Dwg. TPD905–1)
SPECIFICATIONS
Model
Type of Grip
Drive
Impacts per
min.
Sound Level
dB (A)
♦
Vibrations
Level
in.
Pressure
•
Power
m/s
2
2934P2–EU
pistol
1” sq.
825
92.4
105.4
9.1
2940P2–EU
pistol
1”sq.
810
97.2
110.2
9.3
Tested in accordance with ANSI S5.1–1971 at free speed
♦
Tested to ISO8662–1 loaded with frictionbrake to 9 RPM
•
ISO3744
Summary of Contents for 2934P2-EU