background image

PW10A-X-X

Page 8 of 8

TROUBLE SHOOTING

Product discharged from exhaust outlet.

S

Check for diaphragm rupture.

S

Check tightness of (14) diaphragm screw.

Air bubbles in product discharge.

S

Check connections of suction plumbing.

S

Check “O” rings between intake manifold and inlet side fluid caps.

S

Check tightness of (14) diaphragm screw.

Motor blows air or stalls.

S

Check (176) check valve for damage or wear.

S

Check for restrictions in valve / exhaust.

Low output volume, erratic flow, or no flow.

S

Check air supply.

S

Check for plugged outlet hose.

S

Check for kinked (restrictive) outlet material hose.

S

Check for kinked (restrictive) or collapsed inlet material hose.

S

Check for pump cavitation -- suction pipe should be sized at least as

large as the inlet thread diameter of the pump for proper flow if high

viscosity fluids are being pumped. Suction hose must be a non-col-

lapsing type, capable of pulling a high vacuum.

S

Check all joints on the inlet manifolds and suction connections.

These must be air tight.

S

Inspect the pump for solid objects lodged in the diaphragm chamber

or the seat area.

DIMENSIONAL DATA

(Dimensions shown are for reference only, they are displayed in inches and millimeters (mm).

Figure 4

Air Inlet 1/2 - 14 N.P.T.

Inlet

Outlet

Exhaust Port 3/4 - 14 N.P.T.

1-1/4 - 11-1/2 N.P.T.F. - 1

1-1/2 - 11-1/2 N.P.T.F. - 1

11-11/16”

(296.4 mm)

5-27/32”

(148.2 mm)

16-7/8”

(428.6 mm)

8-1/16”

(204.7 mm)

2-15/32”

(62.7 mm)

8-3/4”

(222.3 mm)

1/2”

(12.7 mm)

3/8”

(9.5 mm)

5-15/16”

(150.8 mm)

7-21/32”

(194.5 mm)

14-1/32”

(356.2 mm)

8-1/8”

(206.4 mm)

PN 97999-1078

Summary of Contents for 1" DIAPHRAGM PUMP PW10A-X-X

Page 1: ...3 3 mm Maximum Temperature Limits diaphragm ball seal material E P R EPDM 60_to280_F 51_to 138_C HytrelR 20_ to 150_ F 29_ to 66_ C Nitrile 10_ to 180_ F 12_ to 82_ C SantopreneR 40_to225_F 40_to 107...

Page 2: ...tlet hose or piping from pump WARNING HAZARDOUSMATERIALS Cancauseseriousin juryorpropertydamage Donotattempttoreturnapumptothe factory or service center that contains hazardous material Safe handling...

Page 3: ...ooded suction inlet pressure must not exceed 10 p s i g 0 69 bar OPERATING INSTRUCTIONS S Always flush the pump with a solvent compatible with the material beingpumpedifthematerialbeingpumpedissubject...

Page 4: ...7 220 4 V XXG 637401 XG 96267 G 2 B Y325 225 4 B Y325 220 4 B XXT 637401 XT 96146 T 2 T 96145 A 2 SP 93282 4 T 93281 4 T XXV 637401 XV 95989 3 2 V Y327 225 4 V Y327 220 4 V NOTE Gasket items 19 and 33...

Page 5: ...ly Lubriplate FML 2 Grease to all O rings U Cups mating parts x Apply LoctiteR 242 to threads at assembly Apply PTFE tape to threads at assembly Apply Loctite 271 to threads at assembly U Apply anti s...

Page 6: ...revent cutting O rings upon installation S Lubricate O rings with Lubriplate FML 2 grease S Do not over tighten fasteners refer to torque specification block on view S Re torque fasteners following re...

Page 7: ...ly U 134 135 133 174 k 121 118 173 k 169 k 172 k 171 k 170 167 121 k 174 118 166 k 132 k 141 k 140 200 k 233 176 k PILOT VALVE PART GROUP MAJOR VALVE A replacement 637390 3 Major Valve Service Assembl...

Page 8: ...ose S Check for pump cavitation suction pipe should be sized at leastas large as the inlet thread diameter of the pump for proper flow if high viscosity fluids are being pumped Suction hose must be a...

Reviews: