background image

Page 3 of 8

PW10A-X-X

GENERAL DESCRIPTION

The ARO diaphragm pump offers high volume delivery even at low air

pressure and a broad range of material compatibility options available.

Refer to the model and option chart. ARO pumps feature stall resistant

design, modular air motor / fluid sections.

Air operated double diaphragm pumps utilize a pressure differential in

the air chambers to alternately create suction and positive fluid pressure

in the fluid chambers, ball checks insure a positive flow of fluid.

Pump cycling will begin as air pressure is applied and it will continue to

pump and keep up with the demand. It will build and maintain line pres-

sure and will stop cycling once maximum line pressure is reached (dis-

pensing device closed) and will resume pumping as needed.

AIR AND LUBE REQUIREMENTS

WARNING

EXCESSIVE AIR PRESSURE. Can cause pump

damage, personal injury or property damage.

S

A filter capable of filtering out particleslarger than 50 micronsshould

be used on the air supply. There is no lubrication required other than

the “O” ring lubricant which is applied during assembly or repair.

S

If lubricated air is present, make sure that it is compatible with the

Nitrile seals in the air motor section of the pump.

INSTALLATION

S

Verify correct model / configuration prior to installation.

S

Retorque all external fasteners per specifications prior to start up.

S

Pumps are tested in water at assembly. Flush pump with compatible

fluid prior to installation.

S

When the diaphragm pump is used in a forced-feed (flooded inlet)

situation, it is recommended that a “Check Valve” be installed at the

air inlet.

S

Material supply tubing should be at least the same diameter as the

pump inlet manifold connection.

S

Material supply hose must be reinforced, non-collapsible type com-

patible with the material being pumped.

S

Piping must be adequately supported. Do not use the pump to sup-

port the piping.

S

Use flexible connections (such as hose) at the suction and dis-

charge. These connections should not be rigid piped and must be

compatible with the material being pumped.

S

Secure the diaphragm pump legs to a suitable surface (level and

flat) to insure against damage by vibration.

S

Pumps that need to be submersed must have both wet and non-wet

components compatible with the material being pumped.

S

Submersed pumps must have exhaust pipe above liquid level. Ex-

haust hose must be conductive and grounded.

S

Flooded suction inlet pressure must not exceed 10 p.s.i.g. (0.69

bar).

OPERATING INSTRUCTIONS

S

Always flush the pump with a solvent compatible with the material

being pumped if the material being pumped is subject to “setting up”

when not in use for a period of time.

S

Disconnect the air supply from the pump if it is to be inactive for a few

hours.

PARTS AND SERVICE KITS

Refer to the part views and descriptions as provided on page 4 through 7

for parts identification and Service Kit information.

S

Certain ARO “Smart Parts” are indicated which should be available

for fast repair and reduction of down time.

S

Service kits are divided to service two separate diaphragm pump

functions: 1. AIR SECTION, 2. FLUID SECTION. The FLUID SEC-

TION is divided further to match typical part MATERIAL OPTIONS.

MAINTENANCE

S

Provide a clean work surface to protect sensitive internal moving

parts from contamination from dirt and foreign matter during service

disassembly and reassembly.

S

Keep good records of service activity and include pump in preven-

tive maintenance program.

S

Before disassembling, empty captured material in the outlet man-

ifold by turning the pump upside down to drain material from the

pump.

FLUID SECTION DISASSEMBLY

1. Remove (61) outlet manifold, (60) inlet manifold.

2. Remove (22) balls, (19 and 33) “O” rings (if applicable) and (21)

seats.

3. Remove (15) fluid caps.

NOTE: Only PTFE diaphragm models use a primary diaphragm (7) and

a backup diaphragm (8). Refer to the auxiliary view in the Fluid Section

illustration.

4. Remove the (14) screw, (6) diaphragm washer, (7) or (7 / 8) dia-

phragms, and (5) backup washer.

NOTE: Do not scratch or mar the surface of (1) diaphragm rod.

FLUID SECTION REASSEMBLY

S

Reassemble in reverse order. Refer to the torque requirements on

page 5.

S

Clean and inspect all parts. Replace worn or damaged parts with

new parts as required.

S

Lubricate (1) diaphragm rod and (144) “U” cup with Lubriplate

R

FML-2 grease (94276 grease packet is included in service kit).

S

For models with PTFE diaphragms: Item (8) Santoprene diaphragm

is installed with the side marked “AIR SIDE” towards the pump cen-

ter body. Install the PTFE diaphragm (7) with the side marked

“FLUID SIDE” towards the (15) fluid cap.

S

Re-check torque settings after pump has been re-started and run a

while.

S

Viton

R

and Hytrel

R

are trademarks of the DuPont Company,

S

Kynar

R

is a registered trademark of Penwalt Corp.

S

Loctite

R

is a registered trademark of Henkel Loctite Corporation

S

S

Santoprene

R

is a registered trademark of Monsanto Company, licensed to Advanced Elastomer Systems, L.P.,

S

Lubriplate

R

is a registered trademark of Lubriplate Division (Fiske Brothers)

S

Summary of Contents for 1" DIAPHRAGM PUMP PW10A-X-X

Page 1: ...3 3 mm Maximum Temperature Limits diaphragm ball seal material E P R EPDM 60_to280_F 51_to 138_C HytrelR 20_ to 150_ F 29_ to 66_ C Nitrile 10_ to 180_ F 12_ to 82_ C SantopreneR 40_to225_F 40_to 107...

Page 2: ...tlet hose or piping from pump WARNING HAZARDOUSMATERIALS Cancauseseriousin juryorpropertydamage Donotattempttoreturnapumptothe factory or service center that contains hazardous material Safe handling...

Page 3: ...ooded suction inlet pressure must not exceed 10 p s i g 0 69 bar OPERATING INSTRUCTIONS S Always flush the pump with a solvent compatible with the material beingpumpedifthematerialbeingpumpedissubject...

Page 4: ...7 220 4 V XXG 637401 XG 96267 G 2 B Y325 225 4 B Y325 220 4 B XXT 637401 XT 96146 T 2 T 96145 A 2 SP 93282 4 T 93281 4 T XXV 637401 XV 95989 3 2 V Y327 225 4 V Y327 220 4 V NOTE Gasket items 19 and 33...

Page 5: ...ly Lubriplate FML 2 Grease to all O rings U Cups mating parts x Apply LoctiteR 242 to threads at assembly Apply PTFE tape to threads at assembly Apply Loctite 271 to threads at assembly U Apply anti s...

Page 6: ...revent cutting O rings upon installation S Lubricate O rings with Lubriplate FML 2 grease S Do not over tighten fasteners refer to torque specification block on view S Re torque fasteners following re...

Page 7: ...ly U 134 135 133 174 k 121 118 173 k 169 k 172 k 171 k 170 167 121 k 174 118 166 k 132 k 141 k 140 200 k 233 176 k PILOT VALVE PART GROUP MAJOR VALVE A replacement 637390 3 Major Valve Service Assembl...

Page 8: ...ose S Check for pump cavitation suction pipe should be sized at leastas large as the inlet thread diameter of the pump for proper flow if high viscosity fluids are being pumped Suction hose must be a...

Reviews: