background image

 

 

Intégration Guide_iUI120 

                      32/58   

Copyright © 2013 Ingenico 

900016253 R11 000 01/1416 

 

All rights reserved

 

3.1.1 Software Architecture 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

 
The software architecture is divided into levels:

  

  System  

  Multi-application manager 

  Universal Controller Module Component (UCMC) 

  Independent applications 

 

Telium

 

manager

 

System

 

 

Applications 

 

Resident 

loading 

Bootstrap 

Power up 

Operating system 

Local loading 

Application manager 

Downloading

 

Remote 

diagnostics

 

Local  

diagnostics 

Appli 2 

CB Appli

 

Appli 3 

Appli n 

UCMC 
 

UCM component

 

Transaction 
Flow 

Management

 

USB slave/ 
PSU 5V

 

Memory 

µSD 

SAM 

Display 

Keypad 

USB 

COM 

Ethernet 

GPRS 

MDB 

Bluetooth 

Summary of Contents for iUI120

Page 1: ...Ingenico 28 32 Boulevard de Grenelle 75015 PARIS Tél 33 0 1 58 01 80 00 Fax 33 0 1 58 01 91 35 Ingenico Unattended Product iUI120 I n t é g r a t i o n G u i d e ...

Page 2: ...UI120 Ingenico Unattended product It offers all information needed for a successful integration of iUI120 product into unattended kiosk machines For any sales information please refer to your Ingenico contact into the region Updates table Version Date Nature of modifications Author Visa 0 1 06 02 2014 First Draft R Allirot E Dubois 0 1 15 04 14 Update IC and FCC number O Fabregoule ...

Page 3: ...3 3 6 MDB Slave 16 1 3 3 7 MDB master optional 16 1 3 3 8 Wake Up Jack 17 1 3 3 9 Bluetooth optional 17 1 3 3 10 GPRS optional 18 1 3 3 11 SAM µSD Installation 19 1 3 3 12 Buzzer 20 1 3 3 13 Display 20 1 3 3 14 Maintenance Button and LED 20 1 3 3 15 iUI 120 Keypad 21 1 3 3 16 Cable Protection 22 1 3 3 17 Antenna Installation 23 1 4 Professional installation Requirement 24 1 5 Wake UP function a re...

Page 4: ...installation recommendations 44 6 ASSEMBLY PROCEDURE FOR IUI120 45 6 1 Kiosk minimum volume for iUI 120 45 6 1 1 Volume for iUI 120 without cable gasket 45 6 1 2 Volume for iUI 120 with cable gasket 46 Kiosk preparation for iUI120 new installation 47 6 1 Installing the iUI120 in new kiosk 48 6 1 1 Left horizontal on a shelve inside the kiosk 48 6 1 2 Mounted vertically on a support using EVA stand...

Page 5: ...ed 9 1 3 PRODUCT DISASSEMBLY PROCESS 54 10 STANDARDS 55 10 1 Electrical consumptions 55 10 2 Temperature and humidity 55 10 3 Environmental specification continued 55 10 4 EC standard compliance marking 56 10 5 IC statements 56 10 6 FCC Statement 57 10 7 Environment WEEE Batteries and Packaging 58 ...

Page 6: ...eneral Packet Radio Service GSM Global System for Mobile communications LCD Liquid Crystal Display LLT Local Loading Tool MDB Multi Drop Bus RAM Random Access Memory RS232 Recommended Standard 232 A standard for serial binary communications SAM Secure Access Module the chips storing the electronic cash register in a stored value scheme such as Moneo Proton or VISA Cash SMA SubMiniature version A U...

Page 7: ...on respectful of EVA EPS Standard door module Usage can be indoor or outdoor resisting to harsh environment Remarks For iUC180 iUC180B additional peripherals can be added to build a complete solution such as printer or bar code reader Ingenico does not provide these devices so far but they can be connected to the iUC180 iUC180B through USB or RS232 Ingenico is also offering other iSelf Series modu...

Page 8: ...6 All rights reserved 1 2 1 Diagram of iUI120 connectivity and communications Serial port com0 display Power supply Main Power supply Ethernet 4 USB host GSM GPRS MDB master Serial port com2 Option Option Option Option Bluetooth 1USB device 10 45 V Max 2A MDB slave Keypad iUI120 ...

Page 9: ...tion SDK Support Hot line support Technical assistance After Sales Service Fixed cost repair of iSelf Series products Downloading server centre User licence Installation and commissioning User training Hot line support Technical assistance Softwares Licences User licence for local loading tool LLT User licence for applications software User licence for M OS Licence for software signature tool SAT ...

Page 10: ...Intégration Guide_iUI120 10 58 Copyright 2013 Ingenico 900016253 R11 000 01 1416 All rights reserved 1 3 DESCRIPTION OF IUI120 PRODUCT 1 3 1 iUI120 product views Front view Rear view ...

Page 11: ...lity Buzzer RGB led internal status indicator 1 Maintenance Button µSD 2 SAM 1 SIM optional 1 Jack for wake up wake up mechanism on RS232 connectors Keys 16 keys for maintenance 128 x 64 graphic display maintenance Link Ethernet GSM GPRS optional Bluetooth optional 4 USB host 1 2 A total max 1 USB device 2x RS232 1 optional MDB slave MDB Master optional GPRS detailed characteristics The GPRS conne...

Page 12: ...kbps Uplink up to 42 8 kbps Bluetooth detailed characteristics Characteristic Bluetooth V2 0 Chipset Bluecore 6 Standard compliance Bluetooth v2 1 EDR enhanced data rate Class 2 Profile SPP Other profile to be analysed on request Radio transfer rate 1 Mbit s 2Mbit s EDR Number of supported links 7 slaves to 1 base Range Indoor 10m typical Bluetooth Class 2 mini 10m in free sight Operating conditio...

Page 13: ...uide_iUI120 13 58 Copyright 2013 Ingenico 900016253 R11 000 01 1416 All rights reserved 1 3 3 iUI120 output connectors description Top view Right view COM 0 MDB Slave MDB Master SIM 2 SAMs µSD COM2 Link Wake Up Link ...

Page 14: ...Guide_iUI120 14 58 Copyright 2013 Ingenico 900016253 R11 000 01 1416 All rights reserved Bottom view Left view Ethernet USB Device USB Hosts Bluetooth Antenna GPRS Antenna LLT Maintenance LED LLT Maintenance Button ...

Page 15: ...nnected by type B USB 1 3 3 3 USB host The iUI120 unit can drive 4 USB accessories The connector is standard type A The power available is limited to 1 2A Max dispatched between the 4 USB 1 3 3 4 COM0 link The iUI120 unit can be connected to serial port COM0 The connector type is RJ11 Pin N Function 1 GND 2 Wake up 3 RXD 4 TXD 5 CTS 6 RTS 1 3 3 5 COM2 link optional The iUI120 unit can be connected...

Page 16: ...er cable 1 3 3 7 MDB master optional The iUI120 unit is powered on the MDB connectors by power supply 10 to 45V DC 45V is a maximum See below iUI120 unit can be connected by MDB master if option available The connector type is MDB master 8 pins Mini Fit series 87827 MOLEX iUI120 unit does not support EXE power supply Specific accessory are available A Würth ferrite ref 74271222 or equivalent must ...

Page 17: ...t commercial service to purchase it Warning do not plug in a DC power in the jack It could damage the iUI120 1 3 3 9 Bluetooth optional When the iUI120 unit is ordered with Bluetooth option it must be connected to an external Bluetooth antenna Ingenico can provide an antenna or a standard one can be used This standard Antenna must have an impedance of 50 Ohm and a maximum gain of 0 dBi Ingenico re...

Page 18: ...nit Ingenico can provide an antenna or a standard one can be used This standard Antenna must have an impedance of 50 Ohm and a maximum gain of 3 5 dBi The SIM used for GSM functionality must be assigned to SIM slot Ingenico recommended antennas Antenna type manufacturer model gain impedance Minimum cable length Ingenico Reference bipolar AMPHENOL 90 00234 1 7dBi 50ohm 0 179900131 bipolar HIRSHMANN...

Page 19: ...stallation 1 Disconnect the iUI120 unit from the main power supply 2 Open the SAM door by removing the screw 3 Insert the SAM cards in SAM slot 1 and or slot 2 4 Insert µSD card in µSD slot 5 Insert SIM card in SIM slot 6 Slide the SAM door and screw SAM cover Screwed with M2X6 T6 SIM Slot SAM1 Slot µSD Slot SAM2 Slot 2 ...

Page 20: ...tion The frequency depends of software 1 3 3 13 Display The iUI120 have a black and white display 1 3 3 14 Maintenance Button and LED The iUI120 unit has a maintenance button at the back To enter LLT mode press the button at power up or at restart until the red LED lights on To enter Maintenance mode press the button at power up or at restart until the red LED starts blinking To restart the produc...

Page 21: ...de_iUI120 21 58 Copyright 2013 Ingenico 900016253 R11 000 01 1416 All rights reserved 1 3 3 15 iUI 120 Keypad Remarks The rear display and the keyboard can only be used in maintenance mode and are used for Up and Down ...

Page 22: ...ction A cable sealing sleeve is provided with iUI120 unit to protect the top of product against water runoff Connect the cables and snap in the part on the rear cover to cover the cables This sleeve also holds the antenna tool for GPRS and BT options Proposed position for cables Cable sealing sleeve clipped on back cover ...

Page 23: ... 1 3 3 17 Antenna Installation A tool is provided to help screwing the external antenna 1 Remove the antenna tool from the cable sleeve 2 Insert the SMA antenna cable through the slot of the antenna tool 3 Slide the antenna tool over the SMA Cable connector 4 Screw the cable Antenna tool rest position ...

Page 24: ... machine operator Parking kiosk On off street Other Thus the general public cannot purchase Ingenico hardware or software Partners resellers and Integrators must have qualified electronics engineers to be able to install or integrate our products Furthermore they must follow a specific technical training conducted by Ingenico technical experts In addition installation must follow Ingenico recommen...

Page 25: ...ith button connected on jack optional with Pin 2 of COM0 link COM2 link by pressing the green key on the maintenance keyboard Wake up pin state Hz high impedance Stand by authorized Drive to 0 Wake up Stand by unauthorized The Wake up pin is drive to 0 by the one asking the wake up It could be driven by iUR250 or any devices designed to be compliant Host device IUI120 COM0 2 1 GND 2 Wake up 3 4 5 ...

Page 26: ...Intégration Guide_iUI120 26 58 Copyright 2013 Ingenico 900016253 R11 000 01 1416 All rights reserved 1 5 2 Recommended circuit implementation ...

Page 27: ...égration Guide_iUI120 27 58 Copyright 2013 Ingenico 900016253 R11 000 01 1416 All rights reserved 1 5 3 Power On sequence iUI120 iUR250 iUC150 This configuration describes the worst case for wake up timing ...

Page 28: ...enico Accessories please refer to iselfseries accessories catalog 2 1 2 Optional USB cable An optional USB cable spare part reference 296129367 with short right angle overmolded connectors can be purchased as an accessory This cable is designed to optimize the required volume for iUI120 installation in the kiosk and allows the use of the cable sleeve 2 1 3 Serial cable ...

Page 29: ...Intégration Guide_iUI120 29 58 Copyright 2013 Ingenico 900016253 R11 000 01 1416 All rights reserved 2 1 4 LLT cable ...

Page 30: ...20 30 58 Copyright 2013 Ingenico 900016253 R11 000 01 1416 All rights reserved 2 1 5 Stand by management cables 2 1 5 1 Jack connector Definition of the jack connector 2 1 5 2 COM0 and COM2 Specification available on demand ...

Page 31: ...ium2 technology is designed with a structure supporting several applications without any mutual interference The operating system is a multi task real time preemptive system The inputs and outputs are managed by interrupts This provides for simultaneous processing of peripherals thus increasing system unit performance It is downloadable to FLASH memory ...

Page 32: ...nager Universal Controller Module Component UCMC Independent applications Telium manager System Applications Resident loading Bootstrap Power up Operating system Local loading Application manager Downloading Remote diagnostics Local diagnostics Appli 2 CB Appli Appli 3 Appli n UCMC UCM component Transaction Flow Management USB slave PSU 5V Memory µSD SAM Display Keypad USB COM Ethernet GPRS MDB Bl...

Page 33: ...als It can also manage the transaction flow The applications are modelled around the demands made by the multi application manager Each request or input point represents a processing operation to be performed Each application manages the execution of these processing operations according to its specifications This standardization based on input points simplifies the implementation of the applicati...

Page 34: ...ntenance sub system ensures among other things the downloading of the application software The operating system ensures the start of the multi task core and then runs the applications by making a set of services available to them Multi task management Availability of a pre emptive real time environment based on interruptions events and mailboxes This management enables simultaneous processing whic...

Page 35: ...ions To operate the system unit has to be equipped with its system the application manager the UCMC and at least one application If no application is initialized the application manager displays a message requesting initialization for an application in maintenance mode If at least one application is initialized the terminal is operational The application manager then waits for an event to poll the...

Page 36: ...for Local diagnostics The operator can request the incidents or alarms stored in the terminal The storage function implements two sets of elements o Incident counters Used for repetitive incidents for which only the number of occurrences is significant For example number of power on o Events Exceptional in nature The information content depends on the type of incident Generally this comprises the ...

Page 37: ...ese features provide faster downloading time enhanced security an ease in upgrading and a larger number of software installed on the system unit Local Loading Tool LLT The LLT is used for local software download The LLT is formed by A PC running with Windows Seven Vista Pro XP 2003 Server 2000 Professional SP2 A INGENICO loading software A PC terminal connecting cable Local loading is performed Fr...

Page 38: ...ares are loaded by FTP TCP IP and PPP for optimized loading Downloading performance in V32bis is around 1 4 kbps on the original files Once the connection is set up with the V32bis modem a 120 Kbytes application is downloaded in around 1 minute Automatic dialling and access to downloading server by switched telephone network STN or by X25 TRANSPAC in France using a public PAD or private PAD access...

Page 39: ...are the user is guided on the screen in making his choice The identity of the business is not requested The identity stored in the system unit is automatically transmitted to the server Using the application software on request by the center or merchant Example in France by envelopes In this case downloading takes place entirely automatically The downloading ticket informs the merchant Local loadi...

Page 40: ...s compiler are required These comprise A C compiler GNU an assembler and a link editor for ARM and Thumb A development environment A remote debugger Supply The SDK 30 development station comprises The user license for the M OS software which includes o The operating system o The application manager o The libraries o The associated documentation in PDF format The user license for the Software Authe...

Page 41: ...All rights reserved Technical support Duration 6 months after the training This includes the hot line and updates to the documentations and softwares during this period Software package A set of software packages used to simplify development of applications EMV level 2 is available ...

Page 42: ...S The advanced functions are extremely various with new ones being requested frequently draw statistics and reports about terminal configurations optimise automatic call scheduling download balancing for large estates of terminals be able to display written messages on the terminal using the display or the printer be able to easily configure a complete terminal i e several applications and to down...

Page 43: ...ed to any ports on your terminal or associated equipment the chip card reader or any other part of your terminal Such checks would provide warning of any unauthorised modifications to your terminal and other suspicious behaviour of individuals that have access to your terminal Your terminal detects any tampered state In this state the terminal will repeatedly flash the message Alert Irruption and ...

Page 44: ...enance needs Be aware of the safety regulations Carefully consider the general and local payment security requirements and any impact they may have on the kiosk Carefully consider the ergonomic aspects and also the local acts or recommendations concerning disabled and visually impaired people See environmental specification and especially in case of very cold or humid weather take steps to ensure ...

Page 45: ...120 6 1 KIOSK MINIMUM VOLUME FOR IUI 120 The iUI120 requires a minimum volume inside the kiosk It is detailed in the drawings below 3D design is available on demand 6 1 1 Volume for iUI 120 without cable gasket The minimum volume is 95 4 mm width x 115 mm height x 43 mm deep Picture of iUI 120 without cable gasket minimum volume ...

Page 46: ...58 Copyright 2013 Ingenico 900016253 R11 000 01 1416 All rights reserved 6 1 2 Volume for iUI 120 with cable gasket The minimum volume is 101mm width x 135 mm height x 49 mm deep Picture of iUI 120 with cable gasket minimum volume ...

Page 47: ...IOSK PREPARATION FOR IUI120 NEW INSTALLATION IUI120 can support 3 different mounting ways Left horizontal on a shelve inside the kiosk Mounted vertically on a support following EVA standard recommendation Mounted vertically on a support using bolts or studs 3D step files are also available upon request ...

Page 48: ...rizontal on a shelve inside the kiosk For this configuration there is no specific recommendation 6 1 2 Mounted vertically on a support using EVA standard recommendation EVA recommends using 2 M4 cap bolts distant 68 4 mm to hold internal products In addition we suggest making a M4 holes to lock the iUI120 wit a screw M4 optional lock EVA mounting bolts ...

Page 49: ...co 900016253 R11 000 01 1416 All rights reserved Details of EVA mounting EVA M4 cap bolts Can be weld or screwed on the kiosk Dimensions on the iUI120 regarding position of the receptacles for EVA M4 bolts Picture showing a new installation of the iUI120 ...

Page 50: ...6 1 3 Mounted vertically on a support using bolds or studs Common installation may consider to use 2 weld studs or bolds We suggest using 2 diagonally opposite slots out of the 4of iUI120 On the kiosk 2 M4 studs Length 11 15 mm bolds or holes must be done 2 diagonally opposite weld studs bolds or holes ...

Page 51: ...Intégration Guide_iUI120 51 58 Copyright 2013 Ingenico 900016253 R11 000 01 1416 All rights reserved Detail of dimensions on the iUI120 for 2 diagonally opposite slots mounting ...

Page 52: ...cerning configuration contact Ingenico Technical Support 7 2 OPERATING LIFE Minimum operating life of 5 years 8 CLEANING INSTRUCTIONS The external front face should be carefully cleaned on a regular basis The goal is to keep the display and the keyboard free of dirt and solvents First of all unplug all the wires from the terminal during this operation Good rules for proper cleaning of the terminal...

Page 53: ... UN TRAITEMENT SÉLECTIF The following components and materials if present in the Ingenico product s have to be removed and selectively treated Les composants et matériaux suivants si présents dans le s produit s Ingenico doivent être retirés et faire l objet d un traitement sélectif Components and materials Composants et matériaux Quantity included in product s Quantité contenue dans le s produit ...

Page 54: ... treatment Etapes de base pour retirer les composants et matériaux précédemment identifiés et nécessitant un traitement sélectif Step Etape Product disassembly process Processus de démontage du produit 1 Remove the 4 screws of front casing and of the rear cover Oter les 4 vis du caport avant et du capot arrière 2 Remove the cover remove the FPC Oter le capot ôter le FPC 3 Remove the 4 screws on th...

Page 55: ...in field at 45 days year storage rate 25 C 10 2TEMPERATURE AND HUMIDITY Operating Storage conditions o Relative humidity 5 to 85 non condensing o External temperature range 20 C to 65 C 10 3ENVIRONMENTAL SPECIFICATION CONTINUED Operating conditions o Vibrations resistance NF EN 60068 2 6 and the below conditions 10 tests sequences per axis From 5Hz to 9Hz with 3 3mm amplitude From 9Hz to 200Hz wit...

Page 56: ...e equivalent isotropically radiated power e i r p is not more than that necessary for successful communication Conformément à la réglementation d Industrie Canada le présent émetteur radio peut fonctionner avec une antenne d un type et d un gain maximal ou inférieur approuvé pour l émetteur par Industrie Canada Dans le but de réduire les risques de brouillage radioélectrique à l intention des autr...

Page 57: ...le for compliance could void the user s authority to operate the equipment NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy ...

Page 58: ... batteries The associated symbol means that WEEE and waste batteries must not be thrown away but collected separately and recycled Ingenico ensures that efficient collection and recycling schemes are set up for WEEE and batteries according to the local regulation of your country Please contact your retailers for more detailed information about the compliance solution in place for disposing of your...

Reviews: